Continuous glucose monitoring using a microneedle array sensor coupled with a wireless signal transmitter

被引:85
作者
Kim, Kwang Bok [1 ]
Lee, Won-Chul [2 ]
Cho, Chul-Ho [1 ]
Park, Deog-Su [3 ]
Cho, Seong Je [1 ]
Shim, Yoon-Bo [2 ]
机构
[1] Samsung Elect, Samsung Res, Seoul R&D Campus,34,Seongchon Gil, Seoul 06765, South Korea
[2] Pusan Natl Univ, Dept Chem, Busan 46241, South Korea
[3] Pusan Natl Univ, IBST, Busan 46241, South Korea
关键词
Glucose sensor; Wireless biosensor; Microneedle array; Carboxylated-poly(terthiophene); Point-of care; ELECTRON-TRANSFER; SYSTEMS;
D O I
10.1016/j.snb.2018.10.081
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A minimally invasive wireless biosensor was developed for glucose monitoring using human blood. The sensor probe was shaped in a microneedle array with a cyclic olefin copolymer. FAD-glucose oxidase (GOx) was covalently bound to a terthiophene carboxylic acid (TCA) monomer followed by electropolymerization on a gold-coated microneedle (AuMN) array using the potential cycling method (AuMN/pTCA-GOx). The formation of the sensing probe layer on the needle was confirmed by employing electrochemical and surface characterization experiments. To prevent the interfering species and the detaching of the probe material, the AuMN/pTCA-GOx surface was protected with Nafion. To enhance the repeatability and stability of the sensor, it was pretreated by applying the sequential negative and positive pulses immediately prior to each measurement. The sequential pulse allowed the sensor to have a high repeatability (Coefficient of variation = 1.1%, n = 10), and continuously long-term stability (Coefficient of variation = 5.56% for 72 h). The sensor has an excellent linear response at glucose concentrations between 0.05 and 20.0 mM (R-2 = 0.99) with a sensitivity of 0.22 mu A/mM(-1) cm(-2) (Coefficient of variation = 1.7%) and the detection limit of 19.4 ( +/- 0.62) mu A. The reliability of the proposed method was performed on finger through coupling of the sensor part to a reusable wireless transmitter that sends the measured values to a mobile phone via Bluetooth.
引用
收藏
页码:14 / 21
页数:8
相关论文
共 28 条
[1]   A selective nitric oxide nanocomposite biosensor based on direct electron transfer of microperoxidase: Removal of interferences by co-immobilized enzymes [J].
Abdelwahab, Adel A. ;
Koh, Wei Choon Alvin ;
Noh, Hui-Bog ;
Shim, Yoon-Bo .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (03) :1080-1086
[2]   Electrochemical biosensors based on nanomodified screen-printed electrodes: Recent applications in clinical analysis [J].
Arduini, Fabiana ;
Micheli, Laura ;
Moscone, Danila ;
Palleschi, Giuseppe ;
Piermarini, Silvia ;
Ricci, Francesco ;
Volpe, Giulia .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 79 :114-126
[3]   A MICROELECTROCHEMICAL ENZYME TRANSISTOR RESPONSIVE TO GLUCOSE [J].
BARTLETT, PN ;
BIRKIN, PR .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1552-1559
[4]  
Carr P.W., 1980, IMMOBILIZED ENZYMES
[5]   PVDF-Nafion nanomembranes coated microneedles for in vivo transcutaneous implantable glucose sensing [J].
Chen, Dajing ;
Wang, Cang ;
Chen, Wei ;
Chen, Yuquan ;
Zhang, John X. J. .
BIOSENSORS & BIOELECTRONICS, 2015, 74 :1047-1052
[6]   A selective glucose sensor based on direct oxidation on a bimetal catalyst with a molecular imprinted polymer [J].
Cho, Seong Je ;
Noh, Hui-Bog ;
Won, Mi-Sook ;
Cho, Chul-Ho ;
Kim, Kwang Bok ;
Shim, Yoon-Bo .
BIOSENSORS & BIOELECTRONICS, 2018, 99 :471-478
[7]   CHARACTERIZATION OF ELECTROCHEMICALLY PRETREATED GLASSY-CARBON ELECTRODES [J].
ENGSTROM, RC ;
STRASSER, VA .
ANALYTICAL CHEMISTRY, 1984, 56 (02) :136-141
[8]   Nocturnal hypoglycaemias in type 1 diabetic patients: what can we learn with continuous glucose monitoring? [J].
Guillod, L. ;
Comte-Perret, S. ;
Monbaron, D. ;
Gaillard, R. C. ;
Ruiz, J. .
DIABETES & METABOLISM, 2007, 33 (05) :360-365
[9]   ENZYME ELECTRODES BASED ON IONOMER FILMS COATED ON ELECTRODES [J].
HARKNESS, JK ;
MURPHY, OJ ;
HITCHENS, GD .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 357 (1-2) :261-272
[10]   ELECTRICAL WIRING OF REDOX ENZYMES [J].
HELLER, A .
ACCOUNTS OF CHEMICAL RESEARCH, 1990, 23 (05) :128-134