Visual performance with multifocal intraocular lenses -: Mesopic contrast sensitivity under distance and near conditions

被引:184
作者
Montés-Micó, R
España, E
Bueno, I
Charman, WN
Menezo, JL
机构
[1] Univ Valencia, Fac Phys, Dept Opt, Optometry & Vis Sci Unit, E-46100 Valencia, Spain
[2] La Fe Univ Hosp, Dept Ophthalmol, Valencia, Spain
[3] Univ Manchester, Inst Sci & Technol, Dept Optometry & Neurosci, Manchester M60 1QD, Lancs, England
[4] Univ Valencia, Dept Surg, Valencia, Spain
[5] Mediterranean Ophthalmol Fdn, Valencia, Spain
关键词
D O I
10.1016/S0161-6420(03)00862-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To evaluate distance and near visual performance under bright (photopic) and dim (mesopic) conditions in patients who had undergone uncomplicated cataract extraction with multifocal or monofocal intraocular lens (IOL) implantation. Design: Prospective, nonrandomized, masked, comparative, observational case series. Participants: Thirty-two eyes of 32 patients after zonal-progressive multifocal IOL implantation (Allergan Medical Optics Array SA-40N) and 32 eyes of 32 age-matched patients after monofocal IOL implantation (Allergan Medical Optics SI-40NB). Intervention: All eyes underwent phacoemulsification and IOL implantation. Main Outcome Measures: At 18 months after surgery, the monocular contrast sensitivity (CS) function was measured with sinusoidal grating charts at distance and near, at one photopic luminance level and 2 mesopic luminance levels (85, 5, and 2.5 candelas per square meter). Results: Under bright conditions, CS at distance in the multifocal group was not statistically different (P>0.01) from that in the monofocal group at any tested grating spatial frequency (1.5, 3, 6, 12, and 18 cycles per degree [cpd]). At low luminances, distance CS for the multifocal group was worse than that for the monofocal group at the highest test spatial frequencies (12 and 18 cpd; P<0.01). At near, photopic CS in the multifocal group was lower than at distance; patients with only a monofocal distance correction, however, could not detect the test gratings, even at the highest available contrast. With optimal near spectacle additions (i.e., using the distance correction of the multifocal IOL), there were no significant differences between the photopic near CS values for the multifocal and monofocal groups. When the luminance was decreased, near CS at all spatial frequencies was reduced in both groups. Contrast sensitivity in the near-corrected, multifocal group was significantly worse than in the near-corrected, monofocal group at high spatial frequencies (12 and 18 cpd). Conclusions: This work supports the findings of earlier authors that the Array multifocal IOL, with its center-distance design, is distance biased. Distance CS is within normal limits under bright photopic conditions but shows deficits at higher spatial frequencies (more than approximately 12 cpd) under dim mesopic conditions. Near CS obtained with the multifocal IOL is below that which can be achieved by an appropriate monofocal near correction, for all spatial frequencies and illumination conditions.
引用
收藏
页码:85 / 96
页数:12
相关论文
共 43 条
  • [1] CONTRAST SENSITIVITY AND READING THROUGH MULTIFOCAL INTRAOCULAR LENSES
    AKUTSU, H
    LEGGE, GE
    SHOWALTER, M
    LINDSTROM, RL
    ZABEL, RW
    KIRBY, VM
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (08) : 1076 - 1080
  • [2] ALPERN M, 1961, Am J Ophthalmol, V52, P762
  • [3] THROUGH FOCUS IMAGE QUALITY OF EYES IMPLANTED WITH MONOFOCAL AND MULTIFOCAL INTRAOCULAR LENSES
    ARTAL, P
    MARCOS, S
    NAVARRO, R
    MIRANDA, I
    FERRO, M
    [J]. OPTICAL ENGINEERING, 1995, 34 (03) : 772 - 779
  • [4] Insufficiency of accommodation in patients with advanced AIDS
    Bueno-Gimeno, I
    España-Gregori, E
    Montés-Micó, R
    Díiaz-Llopis, M
    Menezo-Rozalén, JL
    [J]. ANNALS OF OPHTHALMOLOGY, 2002, 34 (02) : 113 - 117
  • [5] CHARMAN W N, 1979, British Journal of Physiological Optics, V33, P10
  • [6] Theoretical and practical performance of a concentric bifocal intraocular implant lens
    Charman, WN
    Murray, IJ
    Nacer, M
    O'Donoghue, EP
    [J]. VISION RESEARCH, 1998, 38 (18) : 2841 - 2853
  • [7] Influence of the luminance level on visual performance with a disposable soft cosmetic tinted contact lens
    Diego, CA
    Montés-Micó, R
    Pons, AM
    Artigas, JM
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2001, 21 (05) : 411 - 419
  • [8] MULTIFOCAL INTRAOCULAR LENSES
    DUFFEY, RJ
    ZABEL, RW
    LINDSTROM, RL
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (04) : 423 - 429
  • [9] EXPLANATION OF 3M DIFFRACTIVE INTRAOCULAR LENSES
    ELLINGSON, FT
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (06) : 697 - 702
  • [10] GIMBEL HV, 1991, OPHTHALMOLOGY, V98, P881