Rapid and simple magnetic solid-phase extraction of bisphenol A from bottled water, baby bottle, and urine samples using green magnetic hydroxyapatite/β-cyclodextrin polymer nanocomposite

被引:29
作者
Bayatloo, Mohammad Reza [1 ]
Nojavan, Saeed [1 ]
机构
[1] Shahid Beheshti Univ, Dept Analyt Chem & Pollutants, GC, Tehran 1983969411, Iran
关键词
Bisphenol A; Hydroxyapatite; Magnetic solid-phase extraction; Nanocomposite; Urine; beta-cyclodextrin polymer; BETA-CYCLODEXTRIN; MASS-SPECTROMETRY; LIQUID; FOOD; INCLUSION; REMOVAL;
D O I
10.1016/j.microc.2022.107180
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bisphenol A (BPA) is a synthetic organic compound widely used as a starting material in plastics synthesis. The high toxicity of BPA has promoted the development of effective analytical methods for its separation and detection in complex samples. Herein, a novel magnetic nanocomposite consisting of hydroxyapatite and beta-cyclodextrin polymer (MHAP/beta-CDP) was designed and synthesized by a novel and convenient method for magnetic solid-phase extraction (MSPE) of BPA. The adsorption mechanisms of the MHAP/beta-CDP toward BPA were mainly based on the hydrophilic interactions and formation of host-guest inclusion complex. The prepared magnetic nanocomposite was characterized by the vibrating-sample magnetometer (VSM), Fourier transform infrared spectroscopy (FT-IR), energy-dispersive X-ray spectroscopy (EDS), field emission scanning electron microscopy (FESEM), X-ray diffraction (XRD) analysis, and thermogravimetric analysis (TGA). To obtain the best extraction conditions, the extraction parameters were optimized. Under the optimized conditions, MSPE combined with high-performance liquid chromatography-diode array detector (HPLC-DAD) was applied for the determination of BPA in bottled water, baby bottle, and urine samples. The proposed method provided low limits of detection (0.06 ng mL(-1)) and quantification (0.18 ng mL(-1)), good linearity (R-2 = 0.996) in the range of 0.50-1000.0 ng mL(-1), good repeatability (3.2-4.1%, n = 4) and reproducibility (4.9-5.4%, n = 3 days). Furthermore, satisfactory relative recoveries in the range of 97.0-102.0% were obtained for quantification of BPA in bottled water, baby bottle, and urine samples.
引用
收藏
页数:10
相关论文
共 45 条
[41]   Inclusion complexes of bisphenol A with cyclomaltoheptaose (β-cyclodextrin):: solubilization and structure [J].
Yang, Zi-Xin ;
Chen, Yong ;
Liu, Yu .
CARBOHYDRATE RESEARCH, 2008, 343 (14) :2439-2442
[42]   Cyclodextrin-based polymer materials: From controlled synthesis to applications [J].
Yao, Xikuang ;
Huang, Peng ;
Nie, Zhihong .
PROGRESS IN POLYMER SCIENCE, 2019, 93 :1-35
[43]   Polydopamine-assisted attachment of β-cyclodextrin onto iron oxide/silica core-shell nanoparticles for magnetic dispersive solid phase extraction of aromatic molecules from environmental water samples [J].
Yazdanpanah, Mina ;
Nojavan, Saeed .
JOURNAL OF CHROMATOGRAPHY A, 2019, 1601 :9-20
[44]   Development of a hydrophilic magnetic amino-functionalized metal-organic framework for the highly efficient enrichment of trace bisphenols in river water samples [J].
Yuan, Yuan ;
Zheng, Xiaowei ;
Lin, Haizhu ;
Li, Yanyao ;
Yang, Meng ;
Liu, Xianglin ;
Deng, Chunhui ;
Fan, Zhengqiu .
TALANTA, 2020, 211 (211)
[45]   Magnetic solid phase extraction of bisphenol A, phenol and hydroquinone from water samples by magnetic and thermo dual-responsive core-shell nanomaterial [J].
Zhou, Qingxiang ;
Lei, Man ;
Wu, Yalin ;
Zhou, Xianqi ;
Wang, Hongyuan ;
Sun, Yi ;
Sheng, Xueying ;
Tong, Yayan .
CHEMOSPHERE, 2020, 238