The association of arterial shear and flow-mediated dilation in diabetes

被引:17
|
作者
Gibbs, Bethany Barone [1 ,2 ]
Dobrosielski, Devon A. [3 ]
Lima, Michael [3 ]
Bonekamp, Susanne [4 ]
Stewart, Kerry J. [3 ]
Clark, Jeanne M. [2 ]
机构
[1] Univ Pittsburgh, Dept Hlth & Phys Activ, Pittsburgh, PA 15260 USA
[2] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Epidemiol, Baltimore, MD USA
[3] Johns Hopkins Sch Med, Div Cardiol, Dept Med, Baltimore, MD USA
[4] Johns Hopkins Sch Med, Div Radiol, Dept Med, Baltimore, MD USA
关键词
diabetes; endothelial function; shear rate; vascular responsiveness; ENDOTHELIAL FUNCTION; BRACHIAL-ARTERY; CARDIOVASCULAR EVENTS; ULTRASOUND ASSESSMENT; REACTIVE HYPEREMIA; STRESS; DILATATION; STIMULUS; ATHEROSCLEROSIS; DYSFUNCTION;
D O I
10.1177/1358863X11411361
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
While adjusting flow-mediated dilation (FMD), a measure of vascular function, for shear rate may be important when evaluating endothelial-dependent vasodilation, the relationship of FMD with shear rate in study populations with cardiovascular risk factors is unclear. We aimed to investigate the association of four measures of shear rate (peak shear rate (SRpeak) and shear rate area under the curve through 30 seconds (SRAUC 0-30), 60 seconds (SRAUC 0-60), and time to peak dilation (SRAUC 0-ttp)) with FMD in 50 study subjects with type 2 diabetes and mild hypertension undergoing baseline FMD testing for an exercise intervention trial. Associations among measures of shear rate and FMD were evaluated using Pearson's correlations and R-2. The four measures of shear rate were highly correlated within subjects, with Pearson's correlations ranging from 0.783 (p < 0.001) to 0.972 (p < 0.001). FMD was associated with each measure of shear rate, having a correlation of 0.576 (p < 0.001) with SRAUC 0-30, 0.529 (p < 0.001) with SRAUC 0-60, and 0.512 (p < 0.001) with SRpeak. Nine of 50 subjects (18%) did not dilate following the shear stimulus. Among the 41 responders, FMD had a correlation of 0.517 (p < 0.001) with SRAUC 0-ttp and similar correlations to those found in the full sample for SRAUC 0-30, SRAUC 0-60, and SRpeak. In conclusion, shear rate appears to explain up to a third of between-person variability in FMD response and our results support the reporting of shear rate and FMD with and without adjustment for shear rate in similar clinical populations with CVD risk factors.
引用
收藏
页码:267 / 274
页数:8
相关论文
共 50 条
  • [1] Shear stress and flow-mediated dilation
    O'Rourke, MF
    Nichols, WW
    HYPERTENSION, 2004, 44 (02) : 119 - 120
  • [2] Sympathetic nervous system activation, arterial shear rate, and flow-mediated dilation
    Thijssen, Dick H. J.
    Atkinson, Ceri L.
    Ono, Kumiko
    Sprung, Victoria S.
    Spence, Angela L.
    Pugh, Christopher J. A.
    Green, Daniel J.
    JOURNAL OF APPLIED PHYSIOLOGY, 2014, 116 (10) : 1300 - 1307
  • [3] Proper "normalization" of flow-mediated dilation for shear
    Harris, Ryan A.
    Padilla, Jaume
    JOURNAL OF APPLIED PHYSIOLOGY, 2007, 103 (03) : 1108 - 1108
  • [4] Potentially Spurious Correlations Between Arterial Size, Flow-Mediated Dilation, and Shear Rate
    Veglia, Fabrizio
    Amato, Mauro
    Giovannardi, Marta
    Ravani, Alessio
    Tedesco, Calogero C.
    Frigerio, Beatrice
    Sansaro, Daniela
    Tremoli, Elena
    Baldassarre, Damiano
    HYPERTENSION, 2014, 64 (06) : 1328 - U359
  • [5] Flow-Mediated Arterial Dilation in Primary Antiphospholipid Syndrome
    Bilora, Franca
    Sartori, Maria Teresa
    Zanon, Ezio
    Campagnolo, Enrico
    Arzenton, Marianna
    Rossato, Alberto
    ANGIOLOGY, 2009, 60 (01) : 104 - 107
  • [6] Flow-mediated dilation and gender in coronary artery disease - arterial size determinates gender differences in flow-mediated dilation
    Mizia-Stec, K.
    Gasior, Z.
    Mizia, M.
    Gomulka, S.
    Jastrzebska-Maj, E.
    Jakubowski, D.
    Walkowicz, W.
    Skiba, W.
    EUROPEAN HEART JOURNAL, 2005, 26 : 301 - 301
  • [7] Flow-mediated dilation
    Parker, BA
    Proctor, DN
    JOURNAL OF APPLIED PHYSIOLOGY, 2005, 99 (04) : 1620 - 1620
  • [8] Association beween resting heart rate, shear and flow-mediated dilation in healthy adults
    Fox, Brandon M.
    Brantley, Lucy
    White, Claire
    Seigler, Nichole
    Harris, Ryan A.
    EXPERIMENTAL PHYSIOLOGY, 2014, 99 (10) : 1439 - 1448
  • [9] Flow-mediated dilation and gender in patients with coronary artery disease: Arterial size influences gender differences in flow-mediated dilation
    Mizia-Stec, Katarzyna
    Gasior, Zbigniew
    Mizia, Magdalena
    Haberka, Maciej
    Holecki, Michal
    Zwolinska, Weronika
    Kanczuga, Katarzyna
    Skowerski, Mariusz
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2007, 24 (10): : 1051 - 1057
  • [10] Flow-mediated dilation: Just a marker of local shear stress?
    Laclaustra, M
    Kaski, JC
    Frangi, AF
    HYPERTENSION, 2005, 45 (03) : E11 - E11