Effect of different tightening protocols on the probability of survival of screw-retained implant-supported crowns

被引:1
作者
Fardin, Vinicius P. [1 ]
Bergamo, Edmara T. P. [1 ]
Bordin, Dimorvan [2 ]
Hirata, Ronaldo [3 ]
Bonfante, Estevam A. [1 ]
Bonfante, Gerson [1 ]
Coelho, Paulo G. [3 ,4 ,5 ]
机构
[1] Univ Sao Paulo, Bauru Coll Dent, Dept Prosthodont & Periodontol, Bauru, SP, Brazil
[2] Univ Universus Veritas UNG, Dept Restorat Dent, Guarulhos, SP, Brazil
[3] NYU, Dept Biomat & Biomimet, Coll Dent, New York, NY 10003 USA
[4] NYU, Hansjorg Wyss Dept Plast Surg, Langone Med Ctr, New York, NY USA
[5] NYU, Tandon Sch Engn, Mech & Aerosp Engn, New York, NY USA
基金
巴西圣保罗研究基金会;
关键词
Dental implants; Biomechanics; Fatigue; Weibull analysis; TORQUE-LIMITING DEVICES; CONSENSUS STATEMENTS; SINGLE CROWNS; RELIABILITY; PERFORMANCE; ZIRCONIA; PRELOAD; COMPLICATIONS; PROSTHESES; DIAMETER;
D O I
10.1016/j.jmbbm.2021.105019
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: This study evaluated the effect of different tightening protocols on the probability of survival of screw-retained implant-supported anterior crowns. Materials and methods: Seventy-two implants with internal conical connections (4.0 x 10mm, Ti-6Al-4V, Colosso, Emfils) were divided into four groups (n = 18 each): 1) Manufacturer's recommendations torque (25 N. cm for abutment's screw and 30 N.cm for crown's screw) (MaT); 2) Retightening after 10 min (ReT); 3) Torque 16% below recommended to simulate an uncalibrated wrench (AgT), and; 4) Temporary crown simulation (TeT), where crowns were torqued to 13 N.cm to simulate manual tightening, subjected to 11,200 cycles to simulate temporary crown treatment time (190 N), and then retightened to manufacturer torque (TeT). All specimens were subjected to cyclic fatigue in distilled water with a load of 190 N until 250,000 cycles or failure. The probability of survival (reliability) to complete a mission of 50,000 cycles was calculated and plotted using the Weibull 2-Parameter analysis. Weibull modulus and number of cycles at which 62.3% of the specimens would fail were also calculated and plotted. The failure mode was characterized in stereo and scanning electron microscopes (SEM). Results: The probability of survival was 69.3% for MaT, 70% for ReT, 54.8% for AgT, and 40.3% for TeT, all with no statistically significant difference. Weibull modulus was approximately 1.0 for all groups. The characteristic number of cycles for failure was 105,000 cycles for MaT, 123,000 for ReT, 82,000 cycles for AgT, and 54,900 cycles for TeT, with no significant difference between groups. The chief failure mode for MaT, ReT, AgT groups was crown screw fracture, whereas abutment screw fracture was the chief failure mode for the TeT group. Conclusion: Tightening protocol did not influence the probability of survival of the screw-retained anterior crowns supported by internal conical implants (Ti-6Al-4V, Colosso, Emfils).
引用
收藏
页数:7
相关论文
共 48 条
  • [1] Al Jabbari Youssef S, 2008, J Prosthodont, V17, P168
  • [2] Effect of Abutment Screw Surface Treatment on Reliability of Implant-Supported Crowns
    Anchieta, Rodolfo Bruniera
    Machado, Lucas Silveira
    Bonfante, Estevam Augusto
    Hirata, Ronaldo
    Freitas, Amilcar Chagas, Jr.
    Coelho, Paulo G.
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (03) : 585 - 592
  • [3] Preload Evaluation of Different Screws in External Hexagon Joint
    Assuncao, Wirley Goncalves
    Delben, Juliana Aparecida
    Tabata, Lucas Fernando
    Barao, Valentim Adelino Ricardo
    Gomes, Erica Alves
    Garcia, Idelmo Rangel, Jr.
    [J]. IMPLANT DENTISTRY, 2012, 21 (01) : 46 - 50
  • [4] Bernardes SR, 2014, INT J ORAL MAX IMPL, V29, P89, DOI 10.11607/jomi.3344
  • [5] Stress dissipation in the bone through various crown materials of dental implant restoration: a 2-D finite element analysis
    Bijjargi, Supriya
    Chowdhary, Ramesh
    [J]. JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2013, 4 (03) : 172 - 177
  • [6] Binon PP, 1996, INT J PROSTHODONT, V9, P511
  • [7] Probability of survival of implant-supported metal ceramic and CAD/CAM resin nanoceramic crowns
    Bonfante, Estevam A.
    Suzuki, Marcelo
    Lorenzoni, Fabio C.
    Sena, Lidia A.
    Hirata, Ronaldo
    Bonfante, Gerson
    Coelho, Paulo G.
    [J]. DENTAL MATERIALS, 2015, 31 (08) : E168 - E177
  • [8] Effects of Implant Diameter and Prosthesis Retention System on the Reliability of Single Crowns
    Bonfante, Estevam A.
    Almeida, Erika O.
    Lorenzoni, Fabio C.
    Coelho, Paulo G.
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (01) : 95 - 101
  • [9] Branemark PI., 1985, TISSUE INTEGRATED PR, P11
  • [10] Dynamic nature of abutment screw retightening: Finite element study of the effect of retightening on the settling effect
    Bulaqi, Haddad Arabi
    Mashhadi, Mahmoud Mousavi
    Safari, Hamed
    Samandari, Mohammad Mandi
    Geramipanah, Farideh
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (05) : 412 - 419