Functional and radiological evaluation of a simple intra operative technique to avoid limb length discrepancy in total hip arthroplasty

被引:12
作者
Desai, Aravind S. [1 ]
Connors, Liz [2 ]
Board, Timothy N. [1 ]
机构
[1] Wrightington Hosp, Ctr Hip Surg, Wigan, England
[2] Edge Hill Univ, Dept Social & Psychol Sci, Ormskirk, England
关键词
Limb length discrepancy; Total hip arthroplasty; LEG-LENGTH; INEQUALITY; JOINT;
D O I
10.5301/HIP.2011.6514
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We aimed to assess the radiological and functional outcome of total hip arthroplasty performed using a simple technique for intra-operative leg length assessment. The comparative group was made up of patients receiving total hip arthroplasty prior to introduction of the technique. Fifty patients were studied in each group. The pre- and 3 month post-operative leg length difference (LLD) was measured radiologically along with pre- and 12 months post-operative Oxford hip scores (OHS) and University of California Los Angeles (UCLA) activity scores. There were no statistically significant differences in pre-operative parameters between the two groups. The mean LLD in the new technique group was 0.46mm which was significantly less than in the control group (p< 0.001). Post operative OHS values were worse when shortening or lengthening was >5mm in both groups. UCLA activity scores were significantly better in the new technique group than in the control group (p< 0.001). The overall radiological and functional outcome of the patients was better in the new technique group. Functional outcome is related to small differences in leg length and our simple new technique can be used to control leg length intraoperatively.
引用
收藏
页码:192 / 198
页数:7
相关论文
共 21 条
[1]   TREATMENT OF PRIMARY OSTEOARTHRITIS OF THE HIP - A COMPARISON OF TOTAL JOINT AND SURFACE REPLACEMENT ARTHROPLASTY [J].
AMSTUTZ, HC ;
THOMAS, BJ ;
JINNAH, R ;
KIM, W ;
GROGAN, T ;
YALE, C .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (02) :228-241
[2]   The value of patient activity level in the outcome of total hip arthroplasty [J].
Beaule, Paul E. ;
Dorey, Frederic J. ;
Hoke, Ryan ;
LeDuff, Michel ;
Amstutz, Harlan C. .
JOURNAL OF ARTHROPLASTY, 2006, 21 (04) :547-552
[3]   Questionnaire on the perceptions of patients about total hip replacement [J].
Dawson, J ;
Fitzpatrick, R ;
Carr, A ;
Murray, D .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (02) :185-190
[4]   A simple intraoperative technique to avoid limb length discrepancy in total hip arthroplasty [J].
Desai, Aravind ;
Barkatali, Bilal ;
Dramis, Asterios ;
Board, Timothy N. .
SURGEON-JOURNAL OF THE ROYAL COLLEGES OF SURGEONS OF EDINBURGH AND IRELAND, 2010, 8 (02) :119-121
[5]  
Edeen J, 1995, Am J Orthop (Belle Mead NJ), V24, P347
[7]  
Hofmann AA, 2000, ORTHOPEDICS, V23, P943
[8]  
Khanduja V, 2006, J BONE JOINT SURG BR, V88B, P712, DOI 10.1302/0301-620X.88B6
[9]   The importance of leg length discrepancy after total hip arthroplasty [J].
Konyves, A ;
Bannister, GC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (02) :155-157
[10]  
Mizuta I, 2002, ACTA MED OKAYAMA, V56, P159