Optical Design and Tolerancing of an Ophthalmological System

被引:8
作者
Sieber, Ingo [1 ]
Martin, Thomas [1 ]
Yi, Allen [2 ]
Li, Likai [2 ]
Rueenach, Olaf [3 ]
机构
[1] Karlsruhe Inst Technol, Inst Appl Comp Sci, D-76344 Eggenstein Leopoldshafen, Germany
[2] Ohio State Univ, Columbus, OH 43210 USA
[3] Ingener GmbH, D-52068 Aachen, Germany
来源
OPTICAL SYSTEM ALIGNMENT, TOLERANCING, AND VERIFICATION VIII | 2014年 / 9195卷
关键词
Freeform optics; tolerance analysis; design for manufacturability; optical modeling and simulation; polymer; optics;
D O I
10.1117/12.2060643
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Tolerance analysis by means of simulation is an essential step in system integration. Tolerance analysis allows for predicting the performance of a system setup of real manufactured parts and for an estimation of the yield with respect to evaluation figures, such as performance requirements, systems specification or cost demands. Currently, optical freeform optics is gaining importance in optical systems design. The performance of freeform optics often strongly depends on the manufacturing accuracy of the surfaces. For this reason, a tolerance analysis with respect to the fabrication accuracy is of crucial importance. The characterization of form tolerances caused by the manufacturing process is based on the definition of straightness, flatness, roundness, and cylindricity. In case of freeform components, however, it is often impossible to define a form deviation by means of this standard classification. Hence, prediction of the impact of manufacturing tolerances on the optical performance is not possible by means of a conventional tolerance analysis. To carry out a tolerance analysis of the optical subsystem, including freeform optics, metrology data of the fabricated surfaces have to be integrated into the optical model. The focus of this article is on design for manufacturability of freeform optics with integrated alignment structures and on tolerance analysis of the optical subsystem based on the measured surface data of manufactured optical freeform components with respect to assembly and manufacturing tolerances. This approach will be reported here using an ophthalmological system as an example.
引用
收藏
页数:10
相关论文
共 16 条
[1]  
Alvarez L.W., 1970, U.S. Patent, Patent No. [3,507,5651, 35075651]
[2]  
Bergemann M, 2007, IFMBE PROC, V14, P267
[3]  
Bergemann M., 2007, SCHRIFTENREIHE I ANG, V17
[4]   A New Mechatronic System to Restore the Accommodation Ability of the Human Eye [J].
Bretthauer, G. ;
Gengenbach, U. ;
Stachs, O. ;
Guthoff, R. .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2010, 227 (12) :935-939
[5]  
Doane John F, 2004, Curr Opin Ophthalmol, V15, P16, DOI 10.1097/00055735-200402000-00004
[6]   Monovision: A review of the scientific literature [J].
Run Johannsdottir, Kamilla ;
Stelmach, Lew B. .
2001, Lippincott Williams and Wilkins (78)
[7]   Experimental increase in accommodative potential after neodymium:yttrium-aluminum-garnet laser photodisruption of paired cadaver lenses [J].
Krueger, RR ;
Sun, XQK ;
Stroh, J ;
Myers, R .
OPHTHALMOLOGY, 2001, 108 (11) :2122-2129
[8]  
Lavin M., 2001, OPTOMETRY TODAY, V5, P34
[9]   Fabrication of microinjection-molded miniature freeform Alvarez lenses [J].
Li, Likai ;
Raasch, Thomas W. ;
Sieber, Ingo ;
Beckert, Erik ;
Steinkopf, Ralf ;
Gengenbach, Ulrich ;
Yi, Allen Y. .
APPLIED OPTICS, 2014, 53 (19) :4248-4255
[10]  
Martin T., 2014, P ACTUATOR, V2014, P169