Reduction of metal artifacts for industrial computed tomography using multipositional data fusion

被引:2
|
作者
Herl, Gabriel [1 ,2 ]
Hiller, Jochen [1 ,3 ,4 ]
Und, Stefan Kasperl [5 ]
Maier, Andreas [6 ]
机构
[1] Fraunhofer Anwendungszentrum CTMT, Dieter Gorlitz Pl 2, D-94469 Deggendorf, Germany
[2] TH Deggendorf, Fraunhofer Anwendungszentrum CTMT, Artefakt Redukt CT Anwendungen, Dieter Gorlitz Pl 1, D-94469 Deggendorf, Germany
[3] TH Deggendorf, CT & Messtech, Dieter Gorlitz Pl 1, D-94469 Deggendorf, Germany
[4] TH Deggendorf, Fak Maschinenbau & Mechatron, Dieter Gorlitz Pl 1, D-94469 Deggendorf, Germany
[5] Fraunhofer Entwicklungszentrum Rontgentech EZRT, Flugpl Str 75, D-90768 Furth, Germany
[6] Friedrich Alexander Univ Erlangen Nurnberg, Lehrstuhls Mustererkennung, Martensstr 3, D-91058 Erlangen, Germany
关键词
X-ray computed tomography; CT; metal artifact reduction; multipositional data fusion; CT; ALGORITHM;
D O I
10.1515/teme-2019-0137
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Metal artifacts represent a major challenge for measuring with X-ray computed tomography. This paper presents a method for multipositional data fusion for the reduction of metal artifacts. For this purpose, several scans of the same object are performed with different object positioning, registered on each other and then reconstructed together using a local quality measure. The added value of the method is demonstrated in practical experiments. In particular, it is shown how plastic structures can be made visible despite strong metal artifacts with little effort and without prior knowledge, giving the method a unique selling point compared to existing metal artefact reduction methods.
引用
收藏
页码:101 / 110
页数:10
相关论文
共 50 条
  • [21] Adaptive Normalized Metal Artifact Reduction (ANMAR) in Computed Tomography
    Meyer, Esther
    Raupach, Rainer
    Schmidt, Bernhard
    Mahnken, Andreas H.
    Kachelriess, Marc
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2560 - 2565
  • [22] Metal Artifact Reduction in Computed Tomography Using Nonequispaced Fourier Transform
    Kratz, Baerbel
    Buzug, Thorsten M.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2720 - 2723
  • [23] Single-Source Dual-Energy Computed Tomography Use of Monoenergetic Extrapolation for a Reduction of Metal Artifacts
    Mangold, Stefanie
    Gatidis, Sergios
    Luz, Oliver
    Koenig, Benjamin
    Schabel, Christoph
    Bongers, Malte N.
    Flohr, Thomas G.
    Claussen, Claus D.
    Thomas, Christoph
    INVESTIGATIVE RADIOLOGY, 2014, 49 (12) : 788 - 793
  • [24] Quality improvement of images with metal artifact reduction using a noise recovery technique in computed tomography
    Morioka, Yusuke
    Ichikawa, Katsuhiro
    Kawashima, Hiroki
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (01) : 169 - 180
  • [25] Markov random field segmentation for industrial computed tomography with metal artefacts
    Jaiswal, Avinash
    Williams, Mark A.
    Bhalerao, Abhir
    Tiwari, Manoj K.
    Warnett, Jason M.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (04) : 573 - 591
  • [26] The application of metal artifact reduction methods on computed tomography scans for radiotherapy applications: A literature review
    Puvanasunthararajah, Sathyathas
    Fontanarosa, Davide
    Wille, Marie-Luise
    Camps, Saskia M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (06): : 198 - 223
  • [27] Model Image-Based Metal Artifact Reduction for Computed Tomography
    Luzhbin, Dmytro
    Wu, Jay
    JOURNAL OF DIGITAL IMAGING, 2020, 33 (01) : 71 - 82
  • [28] Quantifying near metal visibility using dual energy computed tomography and iterative metal artifact reduction in a fracture phantom
    Hakvoort, E. T.
    Wellenberg, R. H. H.
    Streekstra, G. J.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 69 : 9 - 18
  • [29] Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
    Bamberg, Fabian
    Dierks, Alexander
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Becker, Christoph R.
    Johnson, Thorsten R. C.
    EUROPEAN RADIOLOGY, 2011, 21 (07) : 1424 - 1429
  • [30] Reducing Metal Artifacts in Computed Tomography Caused by Hip Endoprostheses Using a Physics-Based Approach
    Prell, Daniel
    Kyriakou, Yiannis
    Kachelriess, Marc
    Kalender, Willi A.
    INVESTIGATIVE RADIOLOGY, 2010, 45 (11) : 747 - 754