Influence of Conventional, CAD-CAM, and 3D Printing Fabrication Techniques on the Marginal Integrity and Surface Roughness and Wear of Interim Crowns

被引:25
作者
Aldahian, Nada [1 ]
Khan, Rawaiz [2 ]
Mustafa, Mohammed [3 ]
Vohra, Fahim [2 ,4 ]
Alrahlah, Ali [1 ,2 ]
机构
[1] King Saud Univ, Coll Dent, Dept Restorat Dent, Operat Div, POB 21069, Riyadh 11475, Saudi Arabia
[2] King Saud Univ, Coll Dent, Engineer Abdullah Bugshan Res Chair Dent & Oral R, Riyadh 11545, Saudi Arabia
[3] Prince Sattam Bin Abdulaziz Univ, Coll Dent, Dept Conservat Dent Sci, POB 173, Al Kharj 11942, Saudi Arabia
[4] King Saud Univ, Coll Dent, Dept Prosthet Dent Sci, POB 21069, Riyadh 11475, Saudi Arabia
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 19期
关键词
interim restoration; CAD-CAM; 3D printing; micro CT; surface wear; marginal misfit; IN-VITRO EVALUATION; MECHANICAL-PROPERTIES; PROVISIONAL CROWN; MICRO-CT; ADAPTATION; CAD/CAM; COMPOSITE; ZIRCONIA; ACCURACY; STRENGTH;
D O I
10.3390/app11198964
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The aim is to assess the influence of fabrication techniques-conventional (CN), CAD-CAM (CC), and 3D printing (3D)-on the marginal fit, adaptation, surface roughness, and wear of interim restorations of crowns. Thirty interim crowns were fabricated using CN, CC, and 3D techniques. Sixty discs were fabricated to evaluate surface wear and surface roughness properties, with 10 disc samples in each group (n = 10). Internal adaptation and marginal integrity of interim crowns were analyzed with micro CT to detect microgaps at selected points. Average surface micro-roughness (Ra) was calculated in micrometers (mu m) using an optical non-contact surface microscope under cyclic loading. Surface wear was evaluated by surface area measurements (mm(3)) using a micro CT. Analysis of variance (ANOVA) and Tukey's post hoc comparison tests with Pearson correlation were performed for data analysis. The highest adaptation means were for CN (269.94 +/- 64 mu m), and the lowest mean value was observed for 3D (197.82 +/- 11.72 mu m) crowns. CN and CC specimens showed comparable adaptation (p > 0.05), which were significantly higher (p < 0.05) than 3D crowns. CN crowns showed significantly higher marginal misfit compared to 3D (p < 0.05) and CC (p < 0.05) crowns. The highest mean surface roughness was observed in the 3D crowns (5.61 +/- 0.33 mu m), whereas the lowest was found in CC crowns (3.28 +/- 0.34 mu m). Better restoration Ra was observed using the CC method followed by CN. CN had the highest wear (17.79 +/- 2.78 mm(3)), and the lowest wear was observed in the 3D (10.81 +/- 2.00 mm(3)) specimen. Low surface wear was observed using 3D printing, followed by CN and CC techniques. The printed specimen showed comparable outcomes to CAD-CAM restoration; however, they were better than CN restoration. A positive correlation between adaptation and surface roughness was observed, indicating an effect of the fabrication technique on material physical property.
引用
收藏
页数:19
相关论文
共 36 条
  • [1] Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns
    Abdullah, Adil Othman
    Tsitrou, Effrosyni A.
    Pollington, Sarah
    [J]. JOURNAL OF APPLIED ORAL SCIENCE, 2016, 24 (03) : 258 - 263
  • [2] Effect of food-simulating liquids on the mechanical properties of provisional restorative materials
    Akova, Tolga
    Ozkomur, Ahmet
    Uysal, Hakan
    [J]. DENTAL MATERIALS, 2006, 22 (12) : 1130 - 1134
  • [3] Marginal Integrity, Internal Adaptation and Compressive Strength of 3D Printed, Computer Aided Design and Computer Aided Manufacture and Conventional Interim Fixed Partial Dentures
    Al Deeb, Laila
    Al Ahdal, Khold
    Alotaibi, Ghaith
    Alshehri, Abdullah
    Alotaibi, Bader
    Alabdulwahab, Faris
    Al Deeb, Modhi
    AlFawaz, Yasser F.
    Vohra, Fahim
    Abduljabbar, Tariq
    [J]. JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2019, 9 (12) : 1745 - 1750
  • [4] Evaluation of Vertical Marginal Adaptation of Provisional Crowns by Digital Microscope
    Al Rifaiy, M. Q.
    [J]. NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2017, 20 (12) : 1610 - 1617
  • [5] Influence of contemporary CAD-CAM milling systems on the fit and adaptation of partially stabilized Zirconia fixed partial dentures
    Al-Aali, Khulud A.
    Alhamdan, Rana S.
    Maawadh, Ahmed M.
    Vohra, Fahim
    Abduljabbar, Tariq
    [J]. PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2021, 37 (01) : 45 - 51
  • [6] A Microcomputed Tomographic Evaluation of Root Canal Morphology of Maxillary Second Premolars in a Pakistani Cohort
    Alkahtany, Mazen F.
    Ali, Saqib
    Khabeer, Abdul
    Shah, Shafqat A.
    Almadi, Khalid H.
    Abdulwahed, Abdulaziz
    Farooq, Imran
    Vohra, Fahim
    Abduljabbar, Tariq
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (11):
  • [7] Almohareb Thamer, 2018, Eur J Dent, V12, P269, DOI 10.4103/ejd.ejd_1_18
  • [8] Amin Bhavya Mohandas, 2015, Contemp Clin Dent, V6, P161, DOI 10.4103/0976-237X.156035
  • [9] 3D printed complete removable dental prostheses: a narrative review
    Anadioti, Eva
    Musharbash, Leen
    Blatz, Markus B.
    Papavasiliou, George
    Kamposiora, Phophi
    [J]. BMC ORAL HEALTH, 2020, 20 (01)
  • [10] A NEW ALL-CERAMIC CROWN - A DENSE-SINTERED, HIGH-PURITY ALUMINA COPING WITH PORCELAIN
    ANDERSSON, M
    ODEN, A
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 1993, 51 (01) : 59 - 64