Plasma protein adsorption on titanium: comparative in situ studies using optical waveguide lightmode spectroscopy and ellipsometry

被引:65
|
作者
Kurrat, R
Walivaara, B
Marti, A
Textor, M
Tengvall, P
Ramsden, JJ
Spencer, ND
机构
[1] ETH Zurich, Dept Mat, Surface Sci & Technol Lab, CH-8092 Zurich, Switzerland
[2] Linkoping Univ, Dept Phys & Measurement Technol, S-58183 Linkoping, Sweden
[3] Univ Basel, Bioctr, Dept Biophys Chem, CH-4056 Basel, Switzerland
关键词
protein adsorption; antibody reactions; titanium; optical sensor; ellipsometry; blood serum; blood plasma; comparison of techniques;
D O I
10.1016/S0927-7765(98)00039-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Blood serum and plasma adsorption combined with antibody techniques was studied at different wall shear rates by means of in situ optical waveguide lightmode spectroscopy (OWLS) using waveguides sputter coated with TiO2. In situ ellipsometry under stagnant flow conditions was used as a reference technique on titanium (Ti) surfaces, which had been sputter coated with TiO2. OWLS experiments at medium or high wall shear rates showed the best reproducibility and the results were quantitatively most similar to those from ellipsometry. Exposure to serum from 15 s to 30 min resulted in increased serum deposition as well as increased, subsequent anti-C3c binding (both ellipsometry and OWLS), but did not show increased amounts of antibodies binding to complement factor 1q (C1q) or IgG. This differs from earlier results [1] using in situ ellipsometry with titanium surfaces covered by a thin natural (thermal) oxide layer, where small but significant amounts of C1q were shown to be present on the surface after short incubation times in serum. Wall shear rates appear to have a significant influence on the magnitude and composition of the protein adlayers. At very low rates (1.5 s(-1)), significantly increased binding of antibodies to complement factor 3c (anti-C3c) on serum-preincubated surfaces was observed. This was coupled with a significantly prolonged lag-time between the initiation of buffer rinsing and the actual removal of material. Factors such as cell geometry, shear rate and viscosity are likely to be the main experimental factors determining the observed kinetics. After incubation in heparinised blood plasma for 3 min, a large subsequent binding of anti-high-molecular-weight kininogen was observed. This indicates a potential intrinsic coagulation activity and is in line with previous ellipsometry/antibody results. The combined OWLS and ellipsometry results show that the two methods agree surprisingly well for the quantitative determinations of protein and antibody adsorption. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:187 / 201
页数:15
相关论文
共 50 条
  • [1] A comparative study of protein adsorption on titanium oxide surfaces using in situ ellipsometry, optical waveguide lightmode spectroscopy, and quartz crystal microbalance/dissipation
    Höök, F
    Vörös, J
    Rodahl, M
    Kurrat, R
    Böni, P
    Ramsden, JJ
    Textor, M
    Spencer, ND
    Tengvall, P
    Gold, J
    Kasemo, B
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2002, 24 (02) : 155 - 170
  • [2] Protein adsorption kinetics under an applied electric field: An optical waveguide lightmode spectroscopy study
    Brusatori, MA
    Tie, Y
    Van Tassel, PR
    LANGMUIR, 2003, 19 (12) : 5089 - 5097
  • [3] Biosensing under an applied voltage using optical waveguide lightmode spectroscopy
    Brusatori, MA
    Van Tassel, PR
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (10): : 1269 - 1277
  • [4] Adsorption of ruthenadendrimers to silica-titania surfaces studied by optical waveguide lightmode spectroscopy (OWLS)
    Constable, EC
    Harverson, P
    Ramsden, JJ
    CHEMICAL COMMUNICATIONS, 1997, (17) : 1683 - 1684
  • [5] Flatfish vitellogenin detection using optical waveguide lightmode spectroscopy-based immunosensor
    Kim
    Namsow
    Ryu, Hyung-Seok
    Kim, Woo-Yeon
    JOURNAL OF MICROBIOLOGY AND BIOTECHNOLOGY, 2007, 17 (09) : 1445 - 1451
  • [6] Application of optical waveguide lightmode spectroscopy in studying the interaction of DNA to DNA-binding protein
    Wu, Zhongwei
    Liu, Quanjun
    Wu, Lingwei
    Xie, Xiao
    Zhuang, Ying
    Wen, Tian
    Bai, Yunfei
    Lu, Zuhong
    Guangxue Xuebao/Acta Optica Sinica, 2007, 27 (03): : 521 - 525
  • [7] A Direct Method for Detecting DNA-Binding Protein Based on Optical Waveguide Lightmode Spectroscopy
    Wu, Zhong-wei
    INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND MATERIALS ENGINEERING (EEME 2014), 2014, : 1041 - 1055
  • [8] Measurement of polyphenol oxidase activity using optical waveguide lightmode spectroscopy-based immunosensor
    Kim, Namsoo
    Kim, Woo-Yeon
    FOOD CHEMISTRY, 2015, 169 : 211 - 217
  • [9] Measurement of film thickness up to several hundreds of nanometers using optical waveguide lightmode spectroscopy
    Picart, C
    Gergely, C
    Arntz, Y
    Voegel, JC
    Schaaf, P
    Cuisinier, FJG
    Senger, B
    BIOSENSORS & BIOELECTRONICS, 2004, 20 (03): : 553 - 561
  • [10] Studies on the Dynamic Process of Seed-Mediated Silver Nanoparticles Growth by Optical Waveguide Lightmode Spectroscopy
    Wu, Zhongwei
    Liu, Quanjun
    Wu, Lingwei
    Wang, Haitao
    Xie, Xiao
    Lu, Zuhong
    ADVANCED SCIENCE LETTERS, 2011, 4 (02) : 516 - 521