Analysis of a deep learning-based method for generation of SPECT projections based on a large Monte Carlo simulated dataset

被引:9
作者
Leube, Julian [1 ]
Gustafsson, Johan [2 ]
Lassmann, Michael [1 ]
Salas-Ramirez, Maikol [1 ]
Tran-Gia, Johannes [1 ]
机构
[1] Univ Wurzburg, Dept Nucl Med, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Lund Univ, Skane Univ Hosp, Med Radiat Phys, S-22185 Lund, Sweden
关键词
Lu-177; Monte Carlo; SPECT; Deep learning; Denoising; RECONSTRUCTION; NETWORK;
D O I
10.1186/s40658-022-00476-w
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: In recent years, a lot of effort has been put in the enhancement of medical imaging using artificial intelligence. However, limited patient data in combination with the unavailability of a ground truth often pose a challenge to a systematic validation of such methodologies. The goal of this work was to investigate a recently proposed method for an artificial intelligence-based generation of synthetic SPECT projections, for acceleration of the image acquisition process based on a large dataset of realistic SPECT simulations. Methods: A database of 10,000 SPECT projection datasets of heterogeneous activity distributions of randomly placed random shapes was simulated for a clinical SPECT/CT system using the SIMIND Monte Carlo program. Synthetic projections at fixed angular increments from a set of input projections at evenly distributed angles were generated by different u-shaped convolutional neural networks (u-nets). These u-nets differed in noise realization used for the training data, number of input projections, projection angle increment, and number of training/validation datasets. Synthetic projections were generated for 500 test projection datasets for each u-net, and a quantitative analysis was performed using statistical hypothesis tests based on structural similarity index measure and normalized root-mean-squared error. Additional simulations with varying detector orbits were performed on a subset of the dataset to study the effect of the detector orbit on the performance of the methodology. For verification of the results, the u-nets were applied to Jaszczak and NEMA physical phantom data obtained on a clinical SPECT/CT system. Results: No statistically significant differences were observed between u-nets trained with different noise realizations. In contrast, a statistically significant deterioration was found for training with a small subset (400 datasets) of the 10,000 simulated projection datasets in comparison with using a large subset (9500 datasets) for training. A good agreement between synthetic (i.e., u-net generated) and simulated projections before adding noise demonstrates a denoising effect. Finally, the physical phantom measurements show that our findings also apply for projections measured on a clinical SPECT/CT system. Conclusion: Our study shows the large potential of u-nets for accelerating SPECT/CT imaging. In addition, our analysis numerically reveals a denoising effect when generating synthetic projections with a u-net. Clinically interesting, the methodology has proven robust against camera orbit deviations in a clinically realistic range. Lastly, we found that a small number of training samples (e.g., similar to 400 datasets) may not be sufficient for reliable generalization of the u-net.
引用
收藏
页数:20
相关论文
共 26 条
[1]   The promise of artificial intelligence and deep learning in PET and SPECT imaging [J].
Arabi, Hossein ;
AkhavanAllaf, Azadeh ;
Sanaat, Amirhossein ;
Shiri, Isaac ;
Zaidi, Habib .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 83 :122-137
[2]  
Chrysostomou C, 2018, 2018 IEEE NUCL SCI S
[3]   Accelerated SPECT image reconstruction with FBP and an image enhancement convolutional neural network [J].
Dietze, Martijn M. A. ;
Branderhorst, Woutjan ;
Kunnen, Britt ;
Viergever, Max A. ;
de Jong, Hugo W. A. M. .
EJNMMI PHYSICS, 2019, 6 (1)
[4]  
Frey EC, 1997, IEEE NUCL SCI CONF R, P1082
[5]   A generic geometric transformation that unifies a wide range of natural and abstract shapes [J].
Gielis, J .
AMERICAN JOURNAL OF BOTANY, 2003, 90 (03) :333-338
[6]  
Kingma DP, 2014, ADV NEUR IN, V27
[7]   EANM procedure guidelines for radionuclide therapy with 177Lu-labelled PSMA-ligands (177Lu-PSMA-RLT) [J].
Kratochwil, Clemens ;
Fendler, Wolfgang Peter ;
Eiber, Matthias ;
Baum, Richard ;
Bozkurt, Murat Fani ;
Czernin, Johannes ;
Delgado Bolton, Roberto C. ;
Ezziddin, Samer ;
Forrer, Flavio ;
Hicks, Rodney J. ;
Hope, Thomas A. ;
Kabasakal, Levant ;
Konijnenberg, Mark ;
Kopka, Klaus ;
Lassmann, Michael ;
Mottaghy, Felix M. ;
Oyen, Wim ;
Rahbar, Kambiz ;
Schoder, Heiko ;
Virgolini, Irene ;
Wester, Hans-Juergen ;
Bodei, Lisa ;
Fanti, Stefano ;
Haberkorn, Uwe ;
Herrmann, Ken .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (12) :2536-2544
[8]  
Ljungberg M, 2013, SER MED PHYS BIOMED, P1
[9]   A MONTE-CARLO PROGRAM FOR THE SIMULATION OF SCINTILLATION CAMERA CHARACTERISTICS [J].
LJUNGBERG, M ;
STRAND, SE .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1989, 29 (04) :257-272
[10]   THE GEOMETRIC TRANSFER-FUNCTION COMPONENT FOR SCINTILLATION CAMERA COLLIMATORS WITH STRAIGHT PARALLEL HOLES [J].
METZ, CE ;
ATKINS, FB ;
BECK, RN .
PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (06) :1059-1070