Influence of heat-exchanging tubes diameter on the gas holdup and bubble dynamics in a bubble column

被引:18
|
作者
Jasim, Ahmed A. [1 ,2 ]
Sultan, Abbas J. [1 ,3 ]
Al-Dahhan, Muthanna H. [1 ,4 ]
机构
[1] Missouri Univ Sci & Technol, Dept Chem & Biochem Engn, Multiphase Reactors Engn & Applicat Lab mReal, Rolla, MO 65409 USA
[2] Amer Univ Iraq, Sulaimani, Iraq
[3] Univ Technol Baghdad, Dept Chem Engn, Baghdad, Iraq
[4] Cihan Univ Erbil, Erbil, Iraq
关键词
Bubble column with vertical internals; Tubes diameter; Local gas holdup; Bubble dynamics; RADIOACTIVE PARTICLE TRACKING; RAY COMPUTED-TOMOGRAPHY; 4-POINT OPTICAL PROBE; MASS-TRANSFER; FT SYNTHESIS; INTERNALS; HYDRODYNAMICS; REACTOR; IMPACT; CONFIGURATION;
D O I
10.1016/j.fuel.2018.09.049
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The effects of the presence of vertical internal tubes and their diameters on the local gas holdup and bubble dynamics, including the specific interfacial area, bubble chord length, and bubble velocity were investigated in a 6 in. bubble column for the air-water system by using a four-point optical fiber probe technique. Two different diameters, 0.5-inch, and 1-inch, of vertical internals equally covering 25% of the column's cross-sectional area (CSA) were used to represent the heat-exchanging tubes utilized in the Fischer Tropsch (FT) process. For both sizes, the vertical internals were uniformly distributed over column CSA. The experiments were performed using the air-water system, in a 6-inch bubble column at superficial gas velocities of 20, 30, and 45 cm/s. The experimental results indicated that the presence of vertical internals and their diameters have a significant effect on the hydrodynamic properties of the bubble column reactor at high superficial gas velocities. The local gas holdup significantly increased in the core region and decreased at the wall regions when the 0.5-inch vertical internals were used. Contrarily, the 1-inch vertical internals enhanced the gas holdup near to the wall regions. Additionally, the bubble chord length and the bubble rise velocity were found to be larger in the presence of vertical internals, especially at high superficial gas velocities. The specific interfacial area with the 0.5-inch internal was much lower than bubble column without vertical internals, but while using 1-inch internals, it was enhanced in the wall regions.
引用
收藏
页码:1191 / 1203
页数:13
相关论文
共 50 条
  • [41] Effects of internals on macroscopic fluid dynamics in a bubble column
    Liu, Shijie
    Liang, Jin
    Li, Qin
    Yu, Hui
    Wang, Haoliang
    Li, Xiangyang
    Yang, Chao
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2025, 77 : 19 - 29
  • [42] Bubble Column Dynamics with Bubble Induced Turbulence and Dispersion
    Chernyshev, Alexander
    Schmidt, Alexander
    11TH INTERNATIONAL CONFERENCE OF NUMERICAL ANALYSIS AND APPLIED MATHEMATICS 2013, PTS 1 AND 2 (ICNAAM 2013), 2013, 1558 : 1071 - 1074
  • [43] Effect of L/D Ratio on Phase Holdup and Bubble Dynamics in Slurry Bubble Column using Optical Fiber Probe Measurements
    Gheni, Saba A.
    Abdulaziz, Yasser I.
    Al-Dahhan, Muthanna H.
    INTERNATIONAL JOURNAL OF CHEMICAL REACTOR ENGINEERING, 2016, 14 (02) : 653 - 664
  • [44] Gas holdup and hydrodynamic flow regime transition in bubble columns
    Kim, Jun Young
    Kim, Bongjun
    Nho, Nam -Sun
    Go, Kang-Seok
    Kim, Woohyun
    Bae, Jong Wook
    Jeong, Sung Woo
    Epstein, Norman
    Lee, Dong Hyun
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2017, 56 : 450 - 462
  • [45] The use of electrical resistance tomography for the characterization of gas holdup inside a bubble column bioreactor containing activated sludge
    Babaei, Roghayyeh
    Bonakdarpour, Babak
    Ein-Mozaffari, Farhad
    CHEMICAL ENGINEERING JOURNAL, 2015, 268 : 260 - 269
  • [46] Effect of fiber type on gas holdup in a cocurrent air-water-fiber bubble column
    Tang, CZ
    Heindel, TJ
    CHEMICAL ENGINEERING JOURNAL, 2005, 111 (01) : 21 - 30
  • [47] Computational fluid dynamics simulation of bubble size and local gas holdup in stirred vessel
    Li L.-C.
    Wang J.-J.
    Gu X.-P.
    Feng L.-F.
    Li B.-G.
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2010, 44 (12): : 2396 - 2400
  • [48] Influence of the bubble size distribution on the bubble column flow regime
    Lucas, D.
    Ziegenhein, T.
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2019, 120
  • [49] Heat transfer with single- and dual-gas distribution in a pressurised bubble column
    Bae, Keon
    Kim, Jun Young
    Go, Kang Seok
    Nho, Nam Sun
    Kim, Dongjae
    Bae, Jong Wook
    Lee, Dong Hyun
    CHEMICAL ENGINEERING SCIENCE, 2023, 265
  • [50] Intrinsic Hydrodynamic Investigation of Three-Phase Bubble Column: Comparative Experimental Study on Gas Holdup
    A. Nakhaei A. Garmroodi Asil
    Sh. Pour
    Theoretical Foundations of Chemical Engineering, 2020, 54 : 331 - 341