Influence of heat-exchanging tubes diameter on the gas holdup and bubble dynamics in a bubble column

被引:18
|
作者
Jasim, Ahmed A. [1 ,2 ]
Sultan, Abbas J. [1 ,3 ]
Al-Dahhan, Muthanna H. [1 ,4 ]
机构
[1] Missouri Univ Sci & Technol, Dept Chem & Biochem Engn, Multiphase Reactors Engn & Applicat Lab mReal, Rolla, MO 65409 USA
[2] Amer Univ Iraq, Sulaimani, Iraq
[3] Univ Technol Baghdad, Dept Chem Engn, Baghdad, Iraq
[4] Cihan Univ Erbil, Erbil, Iraq
关键词
Bubble column with vertical internals; Tubes diameter; Local gas holdup; Bubble dynamics; RADIOACTIVE PARTICLE TRACKING; RAY COMPUTED-TOMOGRAPHY; 4-POINT OPTICAL PROBE; MASS-TRANSFER; FT SYNTHESIS; INTERNALS; HYDRODYNAMICS; REACTOR; IMPACT; CONFIGURATION;
D O I
10.1016/j.fuel.2018.09.049
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The effects of the presence of vertical internal tubes and their diameters on the local gas holdup and bubble dynamics, including the specific interfacial area, bubble chord length, and bubble velocity were investigated in a 6 in. bubble column for the air-water system by using a four-point optical fiber probe technique. Two different diameters, 0.5-inch, and 1-inch, of vertical internals equally covering 25% of the column's cross-sectional area (CSA) were used to represent the heat-exchanging tubes utilized in the Fischer Tropsch (FT) process. For both sizes, the vertical internals were uniformly distributed over column CSA. The experiments were performed using the air-water system, in a 6-inch bubble column at superficial gas velocities of 20, 30, and 45 cm/s. The experimental results indicated that the presence of vertical internals and their diameters have a significant effect on the hydrodynamic properties of the bubble column reactor at high superficial gas velocities. The local gas holdup significantly increased in the core region and decreased at the wall regions when the 0.5-inch vertical internals were used. Contrarily, the 1-inch vertical internals enhanced the gas holdup near to the wall regions. Additionally, the bubble chord length and the bubble rise velocity were found to be larger in the presence of vertical internals, especially at high superficial gas velocities. The specific interfacial area with the 0.5-inch internal was much lower than bubble column without vertical internals, but while using 1-inch internals, it was enhanced in the wall regions.
引用
收藏
页码:1191 / 1203
页数:13
相关论文
共 50 条
  • [21] Local gas holdup and bubble dynamics investigation during microalgae culturing in a split airlift photobioreactor
    Ojha, Aastha
    Al-Dahhan, Muthanna
    CHEMICAL ENGINEERING SCIENCE, 2018, 175 : 185 - 198
  • [22] Gas holdup and mass transfer in bubble column reactors operated at elevated pressure
    Letzel, HM
    Schouten, JC
    Krishna, R
    van den Bleek, CM
    CHEMICAL ENGINEERING SCIENCE, 1999, 54 (13-14) : 2237 - 2246
  • [23] Effect of gas flow rate and nozzle diameter on bubble size and shape distributions in bubble column
    Yan, Hong-jie
    Zhang, He -yang
    Liu, Liu
    Ziegenhein, Thomas
    Zhou, Ping
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2024, 34 (05) : 1710 - 1720
  • [24] Microbubble swarm in a HiGee-aided bubble column reactor: Size, gas holdup, and effective interfacial area
    Wang, Li-Hua
    Liao, Hai-Long
    Zheng, Liang
    Fan, Zhi-Xuan
    Zou, Hai-Kui
    Luo, Yong
    AICHE JOURNAL, 2025,
  • [25] Experimental study of temperature effects on bubble characteristics and gas holdup in electroflotation column
    Issaoui, Radhia
    Ben Mansour, Lassaad
    DESALINATION AND WATER TREATMENT, 2019, 162 : 186 - 192
  • [26] Gas holdup profiles within annular section in a double tube bubble column
    Ohira, Y
    Takahashi, H
    Ando, K
    KAGAKU KOGAKU RONBUNSHU, 1997, 23 (02) : 181 - 187
  • [27] Influence of Gas Density on Hydrodynamics in a Bubble Column
    Tang Xiaojin
    Hou Shuandi
    Zhang Zhanzhu
    ChinaPetroleumProcessing&PetrochemicalTechnology, 2014, 16 (01) : 66 - 70
  • [28] The Influence of the Geometric Properties on the Gas Holdup and Phase Surface Area for Single-Orifice Gas Distributors in a Bubble Column
    Jonach, Thorsten
    Ruzova, Tetiana
    Jordan, Christian
    Harasek, Michael
    Haddadi, Bahram
    CHEMENGINEERING, 2025, 9 (02)
  • [29] The effect of electrolyte concentration on counter-current gas-liquid bubble column fluid dynamics: Gas holdup, flow regime transition and bubble size distributions
    Besagni, Giorgio
    Inzoli, Fabio
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2017, 118 : 170 - 193
  • [30] Simulation Study on Gas Holdup of Large and Small Bubbles in a High Pressure Gas-Liquid Bubble Column
    Tao, Fangfang
    Ning, Shanglei
    Zhang, Bo
    Jin, Haibo
    He, Guangxiang
    PROCESSES, 2019, 7 (09)