Investigation into microstructural properties of fluorapatite Nd-YAG laser clad coatings with PVA and WG binders

被引:25
作者
Chien, C. S. [2 ]
Liao, T. Y. [1 ]
Hong, T. F. [3 ]
Kuo, T. Y. [1 ]
Wu, J. L. [4 ]
Lee, T. M. [5 ]
机构
[1] So Taiwan Univ, Dept Mech Engn, Tainan 710, Taiwan
[2] Chimei Fdn Hosp, Dept Orthopaed, Tainan 710, Taiwan
[3] Natl Pingtung Univ Sci & Technol, Dept Mat Engn, Pingtung 912, Taiwan
[4] Natl Cheng Kung Univ, Dept Mech Engn, Tainan 701, Taiwan
[5] Natl Cheng Kung Univ, Med Coll Inst Oral Med, Tainan 701, Taiwan
关键词
Laser cladding; PVA; WG; Fluorapatite; Ti-6Al-4V; SBF; COMPOSITE COATINGS; HYDROXYAPATITE; BIOMATERIALS; IMPLANTS; TITANIUM; STRENGTH;
D O I
10.1016/j.surfcoat.2010.11.028
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Biomedical implants are generally coated with a thin layer of hydroxyapatite (HA) using a plasma spraying or pulsed laser deposition method. However, the bonding strength between the coating layer and the substrate is relatively low. Moreover, the high temperature of the deposition process causes a structural instability of the HA, and therefore degrades its bioactivity and reduces the service life of the coating layer following implantation. Accordingly, the present study replaces HA with fluorapatite (FA) as the coating material, and examines the effects of two different binders, namely polyvinyl alcohol (PVA) and water glass (WG), on the properties of FA coatings deposited on Ti-6Al-4V substrates using an Nd-YAG laser cladding process. Scanning electron microscopy (SEM) observations reveal that the FA coating has a coral- and dendrite-like structure when mixed with the PVA binder, but a pure dendrite-like structure when mixed with the WG binder. In addition, the Ca/P value of the WG-based FA coating is significantly higher than that of the PVA-based coating. Fluorapatite, Al2O3, CaTiO3 and Ca-3(PO4)(2) phases are observed in both coating layers. However, the XRD analysis results indicate that the microstructure of the WG sample is dominated by Ca-3(PO4)(2) phase while that of the PVA sample is dominated by FA. After soaking in SBF, it was observed that the specimen produced with PVA binder or less laser output power possessed a better apatite induction ability. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:3141 / 3146
页数:6
相关论文
共 23 条
[1]  
Ayed F.B., 2008, CERAM INT, V34, P1885
[2]   Influence of fluorapatite on the properties of thermally sprayed hydroxyapatite coatings [J].
Bhadang, KA ;
Gross, KA .
BIOMATERIALS, 2004, 25 (20) :4935-4945
[3]   Characterization of hydroxyapatite films obtained by pulsed-laser deposition on Ti and Ti-6AL-4v substrates [J].
Blind, O ;
Klein, LH ;
Dailey, B ;
Jordan, L .
DENTAL MATERIALS, 2005, 21 (11) :1017-1024
[4]   Plasma spraying of zirconia-reinforced hydroxyapatite composite coatings on titanium .1. Phase, microstructure and bonding strength [J].
Chang, E ;
Chang, WJ ;
Wang, BC ;
Yang, CY .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1997, 8 (04) :193-200
[5]  
CHEN CZ, 2004, J LASERS, V31, P1021
[6]   Amorphous calcium phosphates: Synthesis, properties and uses in biomaterials [J].
Combes, C. ;
Rey, C. .
ACTA BIOMATERIALIA, 2010, 6 (09) :3362-3378
[7]  
Denissen H. W., 1991, BIOCERAMICS HUMAN BO, P130
[8]  
Egrun C., 2003, J BIOMED MATER RES A, V65, P336
[9]   Bone-like apatite formation on HA/316L stainless steel composite surface in simulated body fluid [J].
Fan Xin ;
Chen Jian ;
Zou Jian-peng ;
Wan Qian ;
Zhou Zhong-cheng ;
Ruan Jian-ming .
TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2009, 19 (02) :347-352
[10]  
Gineste L, 1999, J BIOMED MATER RES, V48, P224, DOI 10.1002/(SICI)1097-4636(1999)48:3<224::AID-JBM5>3.0.CO