Staging of Keratoconus Indices Regarding Tomography, Topography, and Biomechanical Measurements

被引:55
作者
Goebels, Susanne [1 ]
Eppig, Timo [2 ]
Wagenpfeil, Stefan [3 ]
Cayless, Alan [4 ]
Seitz, Berthold [1 ]
Langenbucher, Achim [2 ]
机构
[1] Univ Saarland, Med Ctr, Dept Ophthalmol, D-66421 Homburg, Germany
[2] Univ Saarland, D-66421 Homburg, Germany
[3] Univ Saarland, Inst Med Biometry Epidemiol & Med Informat, D-66421 Homburg, Germany
[4] Open Univ, Dept Phys Sci, Milton Keynes MK7 6AA, Bucks, England
关键词
CORNEAL TOPOGRAPHY; DIAGNOSIS; ANTERIOR; PENTACAM;
D O I
10.1016/j.ajo.2015.01.014
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To derive limits of metric keratoconus indices for classification into keratoconus stages. DESIGN: Validity and reliability analysis of diagnostic tools. METHODS: A total of 126 patients from the keratoconus center of Homburg/Saar were evaluated with respect to Amsler criteria, using Pentacam (Keratoconus Index [KI], Topographic Keratoconus Classification [TKC]), Topographic Modeling System (Smolek/Klyce, Klyce/Maeda), and Ocular Response Analyzer (Keratoconus Match Probability [KMP], Keratoconus Match Index [KMI]). Mean value, standard deviation, 90% confidence interval, and the Youden J index for definition of the thresholds were evaluated. RESULTS: For separation of keratoconus stages 0/1/2/3/4 we derived the following optimum thresholds: for KI 1.05/1.15/1.31/1.49 and for KMI 0.77/0.32/-0.08/-0.3. For Smolek/Klyce and Klyce/Maeda high standard deviations and overlapping confidence intervals were found; therefore no discrete thresholds could be defined. Nevertheless, for them we still found a good sensitivity and specificity in discriminating between healthy (stage 0) and keratoconus (stages 2-4) eyes in comparison with the other indices. CONCLUSIONS: We derived thresholds for the metric keratoconus indices KI and KMI, which allow classification of keratoconus stages. These now need to be validated in clinical use. Smolek/Klyce and Klyce/Maeda were not sufficiently sensitive to allow classification into individual stages, but these indices did show a good specificity and sensitivity in discriminating between keratoconus and healthy eyes. (C) 2015 by Elsevier Inc. All rights reserved.
引用
收藏
页码:733 / 738
页数:6
相关论文
共 22 条
[1]   Intrasession and intersession repeatability of the Pentacam system on posterior corneal assessment in the normal human eye [J].
Chen, Davie ;
Lam, Andrew K. C. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03) :448-454
[2]   Biomechanical and Tomographic Analysis of Unilateral Keratoconus [J].
Fontes, Bruno M. ;
Ambrosio, Renato, Jr. ;
Salomao, Marcella ;
Velarde, Guillermo C. ;
Nose, Walton .
JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (09) :677-681
[3]   Precision of Ocular Response Analyzer [J].
Goebels, Susanne Christiane ;
Seitz, Berthold ;
Langenbucher, Achim .
CURRENT EYE RESEARCH, 2012, 37 (08) :689-693
[4]   Revisiting keratoconus diagnosis and progression classification based on evaluation of corneal asymmetry indices, derived from Scheimpflug imaging in keratoconic and suspect cases [J].
Kanellopoulos, Anastasios John ;
Asimellis, George .
CLINICAL OPHTHALMOLOGY, 2013, 7 :1539-1548
[5]   Corneal hysteresis and corneal resistance factor in keratoectasia: Findings using the Reichert Ocular Response Analyzer [J].
Kirwan, Caitriona ;
O'Malley, Donal ;
O'Keefe, Michael .
OPHTHALMOLOGICA, 2008, 222 (05) :334-337
[6]   Anterior chamber characteristics of keratoconus assessed by rotating Scheimpflug imaging [J].
Kovacs, Illes ;
Mihaltz, Kata ;
Nemeth, Janos ;
Nagy, Zoltan Z. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (07) :1101-1106
[7]   Biomechanical diagnosis of keratoconus: evaluation of the keratoconus match index and the keratoconus match probability [J].
Labiris, Georgios ;
Gatzioufas, Zisis ;
Sideroudi, Haris ;
Giarmoukakis, Athanassios ;
Kozobolis, Vassilios ;
Seitz, Berthold .
ACTA OPHTHALMOLOGICA, 2013, 91 (04) :E258-E262
[8]   Determining in vivo biomechanical properties of the cornea with an ocular response analyzer [J].
Luce, DA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) :156-162
[9]   COMPARISON OF METHODS FOR DETECTING KERATOCONUS USING VIDEOKERATOGRAPHY [J].
MAEDA, N ;
KLYCE, SD ;
SMOLEK, MK .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (07) :870-874
[10]  
MAEDA N, 1994, INVEST OPHTH VIS SCI, V35, P2749