Comparison of Impedance-Source Networks for Two and Multilevel Buck-Boost Inverter Applications

被引:95
作者
Husev, Oleksandr [1 ,2 ]
Blaabjerg, Frede [3 ]
Roncero-Clemente, Carlos [4 ]
Romero-Cadaval, Enrique [4 ]
Vinnikov, Dmitri [5 ]
Siwakoti, Yam P. [3 ]
Strzelecki, Ryszard [6 ,7 ]
机构
[1] Tallinn Univ Technol, Dept Elect Engn, EE-19086 Tallinn, Estonia
[2] Chernihiv Natl Univ Technol, Dept Biomed Radioelect Apparat & Syst, UA-14027 Chernihiv, Ukraine
[3] Aalborg Univ, Inst Energy Technol, DK-9220 Aalborg, Denmark
[4] Univ Extremadura, Sch Ind Engn, Badajoz 06006, Spain
[5] Riga Tech Univ, Inst Ind Elect & Elect Engn, LV-1048 Riga, Latvia
[6] ITMO Univ, Lab Power Elect & Automated Elect Dr, St Petersburg 197101, Russia
[7] Gdynia Maritime Univ, Dept Ship Automat, PL-81225 Gdynia, Poland
关键词
Buck-boost inverter; impedance-source inverters; multilevel systems; Z-SOURCE CONVERTER; MODULATION STRATEGIES; TRADITIONAL INVERTERS; TOPOLOGICAL DESIGN; 3-LEVEL INVERTERS; VOLTAGE; EFFICIENCY; SEQUENCE; FILTER;
D O I
10.1109/TPEL.2016.2569437
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Impedance-source networks are an increasingly popular solution in power converter applications, especially in single-stage buck-boost power conversion to avoid additional front-end dc-dc power converters. In the survey papers published, no analytical comparisons of different topologies have been described, which makes it difficult to choose the best option. Thus, the aim of this paper is to present a comprehensive analytical comparison of the impedance-source-based buck-boost inverters in terms of passive component count and semiconductor stress. Based on the waveform of the input current, i.e., with or without a transformer, and with or without inductor coupling, the impedance-source converters are classified. The main criterion in our comprehensive comparison is the energy stored in the passive elements, which is considered both under constant and predefined high frequency current ripple in the inductors and the voltage ripple across the capacitors. Two-level and multilevel solutions are described. The conclusions provide a "one-stop" information source and a selection guide of impedance source-based buck-boost inverters for different applications.
引用
收藏
页码:7564 / 7579
页数:16
相关论文
共 106 条
[41]   Phase-shifted pulse-width-amplitude modulation for quasi-Z-source cascade multilevel inverter-based photovoltaic power system [J].
Liu, Yushan ;
Ge, Baoming ;
Abu-Rub, Haitham ;
Peng, Fang Zheng .
IET POWER ELECTRONICS, 2014, 7 (06) :1444-1456
[42]   An Effective Control Method for Quasi-Z-Source Cascade Multilevel Inverter-Based Grid-Tie Single-Phase Photovoltaic Power System [J].
Liu, Yushan ;
Ge, Baoming ;
Abu-Rub, Haitham ;
Peng, Fang Z. .
IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2014, 10 (01) :399-407
[43]  
Liu YS, 2013, APPL POWER ELECT CO, P714, DOI 10.1109/APEC.2013.6520288
[44]  
Loh PC, 2006, IEEE POWER ELECTRON, P151
[45]   Reduced common-mode modulation strategies for cascaded multilevel inverters [J].
Loh, PC ;
Holmes, DG ;
Fukuta, Y ;
Lipo, TA .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2003, 39 (05) :1386-1395
[46]   Pulsewidth-modulated 2-source neutral-point-clamped inverter [J].
Loh, Poh Chiang ;
Gao, Feng ;
Blaabjerg, Frede ;
Feng, Shi Yun Charmaine ;
Soon, Kong Ngai Jamies .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2007, 43 (05) :1295-1308
[47]   Comparative evaluation of pulsewidth modulation strategies for z-source neutral-point-clamped inverter [J].
Loh, Poh Chiang ;
Blaabjerg, Frede ;
Wong, Chow Pang .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (03) :1005-1013
[48]   Three-level Z-source inverters using a single LC impedance network [J].
Loh, Poh Chiang ;
Lim, Sok Wei ;
Gao, Feng ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (02) :706-711
[49]   Γ-Z-Source Inverters [J].
Loh, Poh Chiang ;
Li, Ding ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (11) :4880-4884
[50]   Embedded EZ-Source Inverters [J].
Loh, Poh Chiang ;
Gao, Feng ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (01) :256-267