THERMAL SAFETY OF VIBRO-ACOUSTOGRAPHY USING A CONFOCAL TRANSDUCER

被引:5
作者
Chen, Shigao [1 ]
Aquino, Wilkins [2 ]
Alizad, Azra [1 ]
Urban, Matthew W. [1 ]
Kinnick, Randall [1 ]
Greenleaf, James F. [1 ]
Fatemi, Mostafa [1 ]
机构
[1] Mayo Clin, Coll Med, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
[2] Cornell Univ, Dept Civil & Environm Engn, Ithaca, NY 14853 USA
关键词
Vibro-acoustography; Tissue heating; Bio-heat equation; SOFT-TISSUE; IN-VITRO; ULTRASOUND;
D O I
10.1016/j.ultrasmedbio.2009.10.003
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Vibro-acoustography (VA) is an imaging method that forms a two-dimensional (2-D) image by moving two cofocused ultrasound beams with slightly different frequencies over the object in a C-scan format and recording acoustic emission from the focal region at the difference frequency. This article studies tissue heating due to a VA scan using a concentric confocal transducer. The three-dimensional (3-D) ultrasound intensity field calculated by Field II is used with the bio-heat equation to estimate tissue heating due to ultrasound absorption. Results calculated with thermal conduction and with blood perfusion, with conduction and without perfusion and without conduction and without perfusion are compared. Maximum heating due to ultrasound absorption occurs in the transducer's near-field and maximum temperature rise in soft tissue during a single VA scan is below 0.05 degrees C for all three attenuation coefficients evaluated: 0.3, 0.5 and 0.7 dB/cm/MHz. Transducer self-heating during a single VA scan measured by a thermocouple is less than 0.27 degrees C. (E-mail: chen.shigao@mayo.edu) (C) 2010 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:343 / 349
页数:7
相关论文
共 15 条
[1]   Performance of vibro-acoustography in detecting microcalcifications in excised human breast tissue: A study of 74 tissue samples [J].
Alizad, A ;
Fatemi, M ;
Wold, LE ;
Greenleaf, JF .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (03) :307-312
[2]   Image features in medical vibro-acoustography: In vitro and in vivo results [J].
Alizad, Azra ;
Whaley, Dana H. ;
Greenleaf, James F. ;
Fatemi, Mostafa .
ULTRASONICS, 2008, 48 (6-7) :559-562
[3]   Critical issues in breast imaging by vibro-acoustography [J].
Alizad, Azra ;
Whaley, Dana H. ;
Greenleaf, James F. ;
Fatemi, Mostafa .
ULTRASONICS, 2006, 44 (e217-e220) :E217-E220
[4]  
[Anonymous], 1990, PHYS PROPERTIES TISS
[5]  
[Anonymous], 113 NCRP
[6]   SOFT-TISSUE TEMPERATURE RISE CAUSED BY SCANNED, DIAGNOSTIC ULTRASOUND [J].
CURLEY, MG .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (01) :59-66
[7]   Frame rate considerations for real-time abdominal acoustic radiation force impulse imaging [J].
Fahey, Brian J. ;
Palmeri, Mark L. ;
Trahey, Gregg E. .
ULTRASONIC IMAGING, 2006, 28 (04) :193-210
[8]   Ultrasound-stimulated vibro-acoustic spectrography [J].
Fatemi, M ;
Greenleaf, JF .
SCIENCE, 1998, 280 (5360) :82-85
[9]   Imaging elastic properties of biological tissues by low-frequency harmonic vibration [J].
Fatemi, M ;
Manduca, A ;
Greenleaf, JF .
PROCEEDINGS OF THE IEEE, 2003, 91 (10) :1503-1519
[10]   CALCULATION OF PRESSURE FIELDS FROM ARBITRARILY SHAPED, APODIZED, AND EXCITED ULTRASOUND TRANSDUCERS [J].
JENSEN, JA ;
SVENDSEN, NB .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (02) :262-267