ENVIRONMENTAL IMPACT ASSESMENT APPLYING INDICATORS EMBEDDED INTO A SOCIAL HOUSING BIM MODEL

被引:2
作者
Mercader Moyano, Maria Del Pilar [1 ,2 ]
Edith Camporeale, Patricia [3 ,4 ]
Cozar-Cozar, Elias [5 ,6 ]
机构
[1] Univ Seville, Arquitectura, Seville, Spain
[2] Univ Seville, Dept Construcc, Seville, Spain
[3] Univ Nacl La Plata, Arquitectura, Buenos Aires, DF, Argentina
[4] Univ Nacl La Plata, Buenos Aires, DF, Argentina
[5] Univ Seville, Ingn Edificac, Seville, Spain
[6] Univ Seville, Seville, Spain
来源
REVISTA HABITAT SUSTENTABLE | 2019年 / 9卷 / 02期
关键词
Embodied energy; CO2; emissions; construction and demolition waste; computer-aided design; LIFE-CYCLE ASSESSMENT; ENERGY EFFICIENCY; DEMOLITION WASTE; EMBODIED CARBON; EARLY-STAGE; CONSTRUCTION; EMISSIONS; DESIGN; QUANTIFICATION; INTEGRATION;
D O I
10.22320/07190700.2019.09.02.07
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Building Information Modeling (BIM) has become a versatile tool to analyze the building life cycle and to achieve efficient use of natural resources and raw materials, as well as waste reduction, reuse and recycling towards the goal of a decarbonized building stock for 2020 in Europe. This work proposes a new methodology to introduce embodied energy (EE), carbon emissions (CE), construction & demolition waste (CDW), and urban solid waste (USW) indicators into BIM models to assess environmental impact following the work breakdown structure of the Andalusian Construction Cost Database (ACCD). A case study of a social residential block is presented, focused on the concrete structure analysis because of its high impact. The results show the preponderant role that concrete plays in the environmental impact. It is also observed that steel consumes less energy than concrete and provokes less CE as well. Moreover, it offers the possibility of recycling while reducing waste quantity. When analyzed by task, foundations present much less impact than the superstructure. Furthermore, each square meter of the typical housing block generates 76.11kg of CDW, being 75.77 kg of mixed waste, mainly concrete and 0.34 kg of steel waste.
引用
收藏
页码:79 / 93
页数:15
相关论文
共 56 条
[1]   Integrating BIM and new rules of measurement for embodied energy and CO2 assessment [J].
Abanda, F. H. ;
Oti, A. H. ;
Tah, J. H. M. .
JOURNAL OF BUILDING ENGINEERING, 2017, 12 :288-305
[2]  
Agencia Andaluza de la Energia, 2017, DAT EN AND 2016
[3]  
Ajayi e.a., 2015, INT J SUSTAINABLE BU, V6, P14, DOI [10.1080/2093761X.2015.1006708, DOI 10.1080/2093761X.2015.1006708]
[4]  
[Anonymous], CUANTIFICACION RECUR
[5]  
[Anonymous], 2013, TRANSITION SUSTAINAB
[6]  
[Anonymous], 2013, MEDIT MED BIM REVIT
[7]  
[Anonymous], THESIS
[8]  
[Anonymous], 2018, SPAIN LAUNCHES BIM S
[9]   Integration of life cycle assessment in a BIM environment [J].
Anton, Laura Alvarez ;
Diaz, Joaquin .
CREATIVE CONSTRUCTION CONFERENCE 2014, 2014, 85 :26-32
[10]   Building information modeling for sustainable design and LEED® rating analysis [J].
Azhar, Salman ;
Carlton, Wade A. ;
Olsen, Darren ;
Ahmad, Irtishad .
AUTOMATION IN CONSTRUCTION, 2011, 20 (02) :217-224