Thermal performance analysis of a novel geothermal Organic Rankine cycle-bypass flash system based on the latent heat proportion of working fluids

被引:6
|
作者
Li, Weikang [1 ]
Bu, Shujuan [1 ]
Yang, Xinle [2 ]
Huang, Feifei [3 ]
Tang, Meiling [1 ]
Ji, Zhixin [1 ]
Dai, Wenzhi [1 ]
Su, Chang [1 ]
Liu, Xunan [1 ]
机构
[1] Liaoning Tech Univ, Sch Mech Engn, Fuxin 123000, Peoples R China
[2] Liaoning Tech Univ, Dev Ctr New Energy, Fuxin 123000, Peoples R China
[3] Guodian Suzhou Second Thermal Power Co Ltd, Suzhou 234000, Anhui, Peoples R China
关键词
Geothermal water; Saturation temperature of heat source; Latent heat proportion of working fluids; Bypass flash system; Thermal performance; POINT TEMPERATURE DIFFERENCE; PINCH POINT; EXERGOECONOMIC ANALYSIS; ORC; OPTIMIZATION; PLANT; SIMULATION; SELECTION; DESIGN; SINGLE;
D O I
10.1016/j.egyr.2021.10.062
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To reduce the temperature difference of the heat exchanger and improve the thermal performance of organic Rankine cycle (ORC), a novel geothermal ORC-bypass flash system (ORC-f) is proposed. In this system, the latent heat proportion of working fluid and the saturated temperature of heat source are used as the basis for judgments. Further, the influence of heat source temperature and evaporation temperature on the ORC-f system is analyzed with different working fluids and compared with that of ORC system. The results show that when the heat source temperature is 403.15 K, the evaporation temperature is 313 K and 397 K, using R123 with higher latent heat proportion as working fluid, the net output power of ORC-f system is increased by 6.3 kW and 551.23 kW than that of the ORC system; using R114 with lower latent heat proportion as working fluid, the net output power of the ORC-f system is increased by 3.8 kW and 547.4 kW than that of the ORC system. When the saturated heat source temperature is not reached, the working fluid with higher latent heat proportion is used, the net output power and exergy efficiency of the ORC-f system are larger; When the saturated heat source temperature is reached, there is no need to increase the bypass flash system. Further, the thermal performance of the different working fluids of the ORC-f system is similar, and the ORC-f system can reduce the influence of the working fluid on the thermal performance. (C) 2021 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:6806 / 6819
页数:14
相关论文
共 50 条
  • [31] Thermo-economic Analysis of Organic Rankine Cycle System Using HFOs as Working Fluids
    Hu, Shuo-Zhuo
    Li, Jian
    Ge, Zhong
    Duan, Yuan-Yuan
    Yang, Zhen
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2020, 41 (04): : 816 - 821
  • [32] The study on working fluids of airborne power generation system based on Rankine cycle by heat energy
    Guo, Yuan
    2017 INTERNATIONAL SYMPOSIUM ON RESOURCE EXPLORATION AND ENVIRONMENTAL SCIENCE (REES 2017), 2017, 64
  • [33] PERFORMANCE ANALYSIS OF A NOVEL PXS WITH ORGANIC RANKINE CYCLE (ORC) SYSTEM
    Zhang, Shengjun
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 1, 2014,
  • [34] A detailed analysis of waste heat recovery organic Rankine cycle with partial evaporation and different working fluids
    Bellos, Evangelos
    APPLIED THERMAL ENGINEERING, 2025, 263
  • [35] Comparative thermodynamic analysis of a direct vapor generation solar organic Rankine cycle synergistically integrated with latent heat storage for different working fluids
    Kumar, Manoj
    Ray, Alok Kumar
    Rakshit, Dibakar
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2025, 47 (05)
  • [36] A Novel Organic Rankine Cycle System with Improved Thermal Stability and Low Global Warming Fluids
    Panesar, Angad S.
    Morgan, Robert E.
    Miche, Nicolas D. D.
    Heikal, Morgan R.
    ICPER 2014 - 4TH INTERNATIONAL CONFERENCE ON PRODUCTION, ENERGY AND RELIABILITY, 2014, 13
  • [37] Thermodynamic performance analysis a power and cooling generation system based on geothermal flash, organic Rankine cycles, and ejector refrigeration cycle; application of zeotropic mixtures
    Wang, Nan
    Zhang, Su
    Fei, Zhibin
    Zhang, Wei
    Shao, Limin
    Sardari, Farshid
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 40 (40)
  • [38] Influence of working fluid properties on system performance and screen evaluation indicators for geothermal ORC (organic Rankine cycle) system
    Zhai, Huixing
    Shi, Lin
    An, Qingsong
    ENERGY, 2014, 74 : 2 - 11
  • [39] Thermal performance of latent heat energy storage system with/without enhancement under solar fluctuation for Organic Rankine power cycle
    Zhang, Shuai
    Yan, Yuying
    ENERGY CONVERSION AND MANAGEMENT, 2022, 270
  • [40] Simulation and performance analysis of organic Rankine cycle combined heat and power system
    School of Energy and Environment, Southeast University, Nanjing
    210096, China
    不详
    200233, China
    J. Southeast Univ. Engl. Ed., 4 (489-495): : 489 - 495