Super-resolution X-ray imaging with hybrid pixel detectors using electromagnetic source stepping

被引:6
作者
Dreier, T. [1 ,2 ]
Lundstrom, U. [2 ]
Bech, M. [1 ]
机构
[1] Lund Univ, Dept Med Radiat Phys, Clin Sci Lund, Barngatan 4, S-22242 Lund, Sweden
[2] Excillum AB, Jan Stenbecks Torg 17, S-16440 Kista, Sweden
关键词
Computerized Tomography (CT) and Computed Radiography (CR); Data processing methods; X-ray detectors; X-ray generators and sources; MTF;
D O I
10.1088/1748-0221/15/03/C03002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
With increasing demand for high-resolution X-ray images, the super-resolution method allows to estimate a single high-resolution image from several low-resolution images. Hybrid pixel detectors provide high-quality and low-resolution images, which makes them particularlywell suited for super-resolution. However, such detectors consist of a limited number of pixels at high cost. Applying super-resolution with hybrid pixel detectors shows that it is a viable method to obtain high-resolution images. The point-spread function of such detectors can be idealised to be 1 pixel, adding no blur into the image making such detectors the ideal choice for the application of super-resolution X-ray imaging. However, there are charge sharing effects between the pixels caused by the energy and impact position of incoming photons. Utilising an X-ray source, which allows magnetic stepping of the X-ray spot, several slightly shifted images can be obtained without requiring mechanical movements. Registering the shifts between individual images with sub-pixel precision allows to estimate a high-resolution image. With repeatable and equally spaced X-ray spot position patterns, sufficient information can be obtained with only a few images. In this paper, we present the application of super-resolution for X-ray imaging using a Pilatus 100K hybrid pixel detector from Dectris Ltd. and a prototype micro-focus X-ray source from Excillum AB. Moreover, we analyse the image quality for applications in X-ray radiography and tomography. Using a sufficient number of low-resolution images allows us to achieve an increase in resolution, without introducing significant blur or artefacts into the image. Here we quantify the effects on the quality of resulting super-resolution images using different methods of image interpolation, interpolation factors, shifts of the sample on the detector, and amount of low-resolution images.
引用
收藏
页数:8
相关论文
共 17 条
  • [1] X-ray imaging with the PILATUS 100k detector
    Bech, M.
    Bunk, O.
    David, C.
    Kraft, P.
    Broennimann, C.
    Eikenberry, E. F.
    Pfeiffer, F.
    [J]. APPLIED RADIATION AND ISOTOPES, 2008, 66 (04) : 474 - 478
  • [2] Determining the MTF of medical imaging displays using edge techniques
    Chawla, AS
    Roehrig, H
    Rodriguez, JJ
    Fan, JH
    [J]. JOURNAL OF DIGITAL IMAGING, 2005, 18 (04) : 296 - 310
  • [3] A USB 3.0 readout system for Timepix3 detectors with on-board processing capabilities
    Dreier, T.
    Krapohl, D.
    Maneuski, D.
    Lawal, N.
    Schoewerling, J. O.
    O'Shea, V.
    Frojdh, C.
    [J]. JOURNAL OF INSTRUMENTATION, 2018, 13
  • [4] Fast MTF measurement of CMOS imagers using ISO 12233 slanted-edge methodology
    Estribeau, M
    Magnan, P
    [J]. DETECTORS AND ASSOCIATED SIGNAL PROCESSING, 2004, 5251 : 243 - 252
  • [5] Gilman A, 2008, DELTA 2008: FOURTH IEEE INTERNATIONAL SYMPOSIUM ON ELECTRONIC DESIGN, TEST AND APPLICATIONS, PROCEEDINGS, P55, DOI 10.1109/DELTA.2008.104
  • [6] Super-Resolution in Medical Imaging
    Greenspan, Hayit
    [J]. COMPUTER JOURNAL, 2009, 52 (01) : 43 - 63
  • [7] Efficient subpixel image registration algorithms
    Guizar-Sicairos, Manuel
    Thurman, Samuel T.
    Fienup, James R.
    [J]. OPTICS LETTERS, 2008, 33 (02) : 156 - 158
  • [8] PILATUS: A single photon counting pixel detector for X-ray applications
    Henrich, B.
    Bergamaschi, A.
    Broennimann, C.
    Dinapoli, R.
    Eikenberry, E. F.
    Johnson, I.
    Kobas, M.
    Kraft, P.
    Mozzanica, A.
    Schmitt, B.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01) : 247 - 249
  • [9] IMPROVING RESOLUTION BY IMAGE REGISTRATION
    IRANI, M
    PELEG, S
    [J]. CVGIP-GRAPHICAL MODELS AND IMAGE PROCESSING, 1991, 53 (03): : 231 - 239
  • [10] MuhRec-A new tomography reconstructor
    Kaestner, Anders P.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 651 (01) : 156 - 160