A multi institutional comparison of imaging dose and technique protocols for neonatal chest radiography

被引:8
|
作者
Gunn, C. [1 ]
O'Brien, K. [2 ,3 ]
Fossa, K. [4 ]
Tonkopi, E. [2 ]
Lanca, L. [5 ,6 ,7 ]
Martins, C. T. [5 ,8 ]
Muller, H. [9 ,10 ]
Friedrich-Nel, H. [10 ]
Abdolell, M. [2 ]
Johansen, S. [11 ,12 ]
机构
[1] Dalhousie Univ, Sch Hlth Sci, Halifax, NS, Canada
[2] Dalhousie Univ, Fac Med, Halifax, NS, Canada
[3] IWK Hlth Ctr, Diagnost Imaging, Halifax, NS, Canada
[4] Oslo Univ Hosp, Rikshosp, Div Diagnost & Intervent, Oslo, Norway
[5] Inst Poliecn Lisboa, ESTeSL Escola Super Tecnol Saude Lisboa, Lisbon, Portugal
[6] Karolinska Inst, Stockholm, Sweden
[7] Singapore Inst Technol, Hlth & Social Sci Cluster, Singapore, Singapore
[8] Hosp Santa Maria, Radiol Dept, Ctr Hosp Lisboa Norte, EPE, Lisbon, Portugal
[9] Cent Univ Technol, Fac Hlth & Environm Sci, Free State CUT, Bloemfontein, South Africa
[10] Univ Acad Hosp, Dept Clin Imaging Sci, Bloemfontein, South Africa
[11] Oslo Metropolitan Univ OsloMet, Fac Hlth Sci, Oslo, Norway
[12] Oslo Univ Hosp, Dept Oncol, Div Canc Med, Oslo, Norway
关键词
Chest x-ray; Paediatric imaging; Exposure parameters; BREAST-CANCER; OPTIMIZATION; QUALITY; WOMEN; RISK;
D O I
10.1016/j.radi.2019.10.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: The focus on paediatric radiation dose reduction supports reevaluation of paediatric imaging protocols. This is particularly important in the neonates where chest radiographs are frequently requested to assess respiratory illness and line placement. This study aims to assess the impact of neonatal chest radiographic protocols on patient dose in four hospitals in different countries. Methods: Exposure parameters, collimation, focus to skin distance (FSD) and radiation dose from 200 neonatal chest radiographs were registered prospectively. Inclusion criteria consisted of both premature and full-term neonates weighing between 1000 and 5000 g. Only data from the examinations meeting diagnostic criteria and approved for the clinical use were included. Radiation dose was assessed using dose area product (DAP). Results: The lowest DAP value (4.58 mGy cm(2)) was recorded in the Norwegian hospital, employing a high kVp, low mAs protocol using a DR system. The Canadian hospital recorded the highest DAP (9.48), using lower kVp and higher mAs with a CR system, including the addition of a lateral projection. The difference in the mean DAP, weight, field of view (FOV) and kVp between the hospitals is statistically significant (p < 0.001). Conclusion: Use of non-standardised imaging protocols in neonatal chest radiography results in differences in patient dose across hospitals included in the study. Using higher kVp, lower mAs and reducing the number of lateral projections to clinically relevant indications result in a lower DAP measured in the infant sample studied. Further studies to examine image quality based on exposure factors and added filtration are recommended. Implications for practice: Reevaluation of paediatric imaging protocols presents an opportunity to reduce patient dose in a population with increased sensitivity to ionising radiation. (c) 2019 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:E66 / E72
页数:7
相关论文
共 50 条
  • [41] Evaluation of pulmonary nodules and infection on chest CT with radiation dose equivalent to chest radiography: Prospective intra-individual comparison study to standard dose CT
    Martini, K.
    Barth, B. K.
    Nguyen-Kim, T. D. L.
    Baumueller, S.
    Alkadhi, H.
    Frauenfelder, T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (02) : 360 - 365
  • [42] Chest radiography as a biomarker of ageing: artificial intelligence-based, multi-institutional model development and validation in Japan
    Mitsuyama, Yasuhito
    Matsumoto, Toshimasa
    Tatekawa, Hiroyuki
    Walston, Shannon L.
    Kimura, Tatsuo
    Yamamoto, Akira
    Watanabe, Toshio
    Miki, Yukio
    Ueda, Daiju
    LANCET HEALTHY LONGEVITY, 2023, 4 (09): : E478 - E486
  • [43] 350-KV CHEST RADIOGRAPHY HAS NO DIAGNOSTIC ADVANTAGE - A COMPARISON WITH 140-KV TECHNIQUE
    HERMAN, PG
    DRUMMEY, J
    SWENSSON, RG
    HESSEL, SJ
    BALIKIAN, JP
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 138 (03) : 485 - 489
  • [44] Comparison of chest radiography, chest digital tomosynthesis and low dose MDCT to detect small ground-glass opacity nodules: an anthropomorphic chest phantom study
    Doo, Kyung Won
    Kang, Eun-Young
    Yong, Hwan Seok
    Ham, Soo-Youn
    Lee, Ki Yeol
    Choo, Ji Yung
    EUROPEAN RADIOLOGY, 2014, 24 (12) : 3269 - 3276
  • [45] Influence of the use of various imaging units and projections on the radiation dose received by children during chest digital radiography
    Xu, Hongrong
    Huang, Kaiping
    Liu, Bo
    Cai, Jinhua
    Zheng, Huan
    Zheng, Helin
    Yang, Qiurui
    Yao, Changhong
    PLOS ONE, 2021, 16 (08):
  • [46] Comparison of chest radiography, chest digital tomosynthesis and low dose MDCT to detect small ground-glass opacity nodules: an anthropomorphic chest phantom study
    Kyung Won Doo
    Eun-Young Kang
    Hwan Seok Yong
    Soo-Youn Ham
    Ki Yeol Lee
    Ji Yung Choo
    European Radiology, 2014, 24 : 3269 - 3276
  • [47] Selenium radiography versus storage phosphor imaging. comparison of visualization of specific Anatomic regions of the chest
    Biemans, JMA
    Van Heesewijk, JPM
    Van der Graaf, Y
    INVESTIGATIVE RADIOLOGY, 2002, 37 (01) : 47 - 51
  • [48] IMAGING PROPERTIES OF DIGITAL IMAGE INTENSIFIER RADIOGRAPHY COMPARED WITH CONVENTIONAL X-RAY TECHNIQUE FOR CHEST EXAMINATIONS
    DOLKEN, W
    KRAHE, T
    LANDWEHR, P
    LACKNER, K
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1989, 150 (01): : 86 - 92
  • [49] Radiation dose reduction for chest radiography of infants in intensive care units using a high peak kilovoltage-technique
    Yahav-Dovrat, Anat
    Elbakri, Idris
    Rozovsky, Katya
    Abd Elkader, Amir
    Koplewitz, Benjamin
    PEDIATRIC RADIOLOGY, 2022, 52 (05) : 874 - 882
  • [50] Radiation dose reduction for chest radiography of infants in intensive care units using a high peak kilovoltage-technique
    Anat Yahav-Dovrat
    Idris Elbakri
    Katya Rozovsky
    Amir Abd Elkader
    Benjamin Koplewitz
    Pediatric Radiology, 2022, 52 : 874 - 882