1.5 kA Bi-2223HTS current leads for SMES magnets

被引:6
作者
Jang, HM [1 ]
Oh, SS
Ha, HS
Cho, JW
Ha, DW
Kim, HJ
Seong, KC
Kwon, YK
Ryu, KS
Kim, SH
机构
[1] Korea Electrotechnol Res Inst, Changwon, South Korea
[2] Gyeongsang Natl Univ, Dept Elect Engn, Chinju, South Korea
关键词
Bi-2223; HTS current lead; heat input;
D O I
10.1109/77.920387
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
1.5 kA class Bi-2223 BTS current leads far superconducting magnetic energy storage(SMES) magnet were fabricated and tested, The HTS leads were composed of Bi-2223/Ag-1 at%Au tapes fabricated by PIT process and stainless steel former and Shg were connected to conventional gas-cooled copper Leads. Using a calorimetric method, heat input to the liquid helium through the HTS leads was estimated to be 0.395 W/lead when the warm end part's temperature was 65 K which was slightly greater than the calculated value of 0.35 W/lead. The measured critical current of the HTS leads was about 1.6 kA when the warm end part's temperature was 80 K. This measured value was wed consistent with computed values.
引用
收藏
页码:2547 / 2550
页数:4
相关论文
共 6 条
  • [1] LOW THERMAL CONDUCTIVE BI-2223 TAPES SHEATHED WITH AG-AU ALLOYS
    FUJISHIRO, H
    IKEBE, M
    NOTO, K
    MATSUKAWA, M
    SASAOKA, T
    NOMURA, K
    SATO, J
    KUMA, S
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 1994, 30 (04) : 1645 - 1650
  • [2] HULL JR, 1993, IEEE T MAGNETICS, V3
  • [3] Test results of high temperature superconductor current lead at 14.5 kA operation
    Isono, T
    Hamada, K
    Ando, T
    Tsuji, H
    Yasukawa, Y
    Tomioka, A
    Nozawa, M
    Konno, M
    Sakaki, K
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 519 - 522
  • [4] IWASA Y, 1994, CASE STUDIES SUPERCO, P125
  • [5] Optimum reduction of self field effects in a Bi-2223 stacked superconducting bus bar
    Nah, W
    Kang, H
    Park, IH
    Joo, J
    Oh, SS
    Ryu, KS
    Yoo, J
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 960 - 963
  • [6] WEISEND JG, 1998, PROPERTIES CRYOGENIC, P23