Numerical Study on Fluid-Structure Interaction in a Patient-Specific Abdominal Aortic Aneurysm for Evaluating Wall Heterogeneity and Material Model Effects on its Rupture

被引:12
作者
Mesri, Y. [1 ,2 ]
Niazmand, H. [1 ,2 ]
Deyranlou, A. [1 ,2 ]
机构
[1] Ferdowsi Univ Mashhad, Dept Mech Engn, Mashhad, Iran
[2] Ferdowsi Univ Mashhad, Res Ctr Biomed Engn, Mashhad, Iran
关键词
Abdominal aortic aneurysm; Fluid-structure interaction; Material model; Wall thickness; INTRALUMINAL THROMBUS; BLOOD-FLOW; STRESS-ANALYSIS; RISK; BIOMECHANICS; IDENTIFICATION; PREDICTION; MECHANICS; DIAMETER; GEOMETRY;
D O I
10.18869/acadpub.jafm.73.243.27678
中图分类号
O414.1 [热力学];
学科分类号
摘要
Abdominal Aortic Aneurysm (AAA) is one of the main cardiovascular diseases, which threats human's health while it appears, develops and in crucial cases ruptures and leads to hemorrhage. In the current work, we aim to investigate numerically the transient blood flow in a patient-specific AAA model, while effects of wall compliance is considered by employing the fluid-structure interaction method. The AAA model is reconstructed from acquired CT angiographic data of a patient diagnosed with AAA and an intraluminal thrombus (ILT). For the comparison purposes two different material models, i.e. isotropic and anisotropic are considered. Additionally, to have a better estimation, wall thickness variability is compared with simpler uniform wall thickness model. In this study Navier-Stokes equations along with elastodynamics equation are coupled through Arbitrary Lagrangian-Eulerian formulation method and solved numerically. Findings demonstrate that the isotropic material model with uniform wall thickness significantly underestimates wall stresses as compared to the anisotropic material model with variable wall thickness. Indeed, results emphasize that considering vessel wall as an anisotropic, heterogeneous (variable thickness) structure estimates much higher wall stresses comparing with isotropic, uniform thickness model. Therefore, given realistic vessel wall structure and the fact that the anisotropic, variable wall thickness model predicts higher wall stresses, it could be a more reliable model to give an accurate estimation to physicians to diagnose the stage of a disease and choosing an appropriate therapeutic procedure.
引用
收藏
页码:1699 / 1709
页数:11
相关论文
共 50 条
  • [31] Effects of aspect ratio, wall thickness and hypertension in the patient-specific computational modeling of cerebral aneurysms using fluid-structure interaction analysis
    Sun, Hong Tao
    Sze, Kam Yim
    Tang, Abraham Yik Sau
    Tsang, Anderson Chun On
    Yu, Alfred Cheuk Hang
    Chow, Kwok Wing
    [J]. ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2019, 13 (01) : 229 - 244
  • [32] Fluid-Structure Simulations of a Ruptured Intracranial Aneurysm: Constant versus Patient-Specific Wall Thickness
    Voss, S.
    Glasser, S.
    Hoffmann, T.
    Beuing, O.
    Weigand, S.
    Jachau, K.
    Preim, B.
    Thevenin, D.
    Janiga, G.
    Berg, P.
    [J]. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2016, 2016
  • [33] Comparative study of arterial wall models for numerical fluid-structure interaction simulation of aortic arch aneurysms
    Ferreira da Silva, Mario Luis
    Goncalves, Saulo de Freitas
    Huebner, Rudolf
    [J]. JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2022, 44 (05)
  • [34] Progression of Abdominal Aortic Aneurysm Towards Rupture: Refining Clinical Risk Assessment Using a Fully Coupled Fluid-Structure Interaction Method
    Xenos, Michalis
    Labropoulos, Nicos
    Rambhia, Suraj
    Alemu, Yared
    Einav, Shmuel
    Tassiopoulos, Apostolos
    Sakalihasan, Natzi
    Bluestein, Danny
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2015, 43 (01) : 139 - 153
  • [35] Experimental unsteady flow study in a patient-specific abdominal aortic aneurysm model
    Stamatopoulos, Ch.
    Mathioulakis, D. S.
    Papaharilaou, Y.
    Katsamouris, A.
    [J]. EXPERIMENTS IN FLUIDS, 2011, 50 (06) : 1695 - 1709
  • [36] Experimental unsteady flow study in a patient-specific abdominal aortic aneurysm model
    Ch. Stamatopoulos
    D. S. Mathioulakis
    Y. Papaharilaou
    A. Katsamouris
    [J]. Experiments in Fluids, 2011, 50 : 1695 - 1709
  • [37] Effect of aortic bifurcation geometry on pressure and peak wall stress in abdominal aorta: Fluid-structure interaction study
    Jagos, Jiri
    Schwarz, David
    Polzer, Stanislav
    Bursa, Jiri
    [J]. MEDICAL ENGINEERING & PHYSICS, 2023, 118
  • [38] Fluid-structure interaction of turbulent pulsatile flow within a flexible wall axisymmetric aortic aneurysm model
    Khanafer, Khalil M.
    Bull, Joseph L.
    Berguer, Ramon
    [J]. EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2009, 28 (01) : 88 - 102
  • [39] Modeling and evaluation of biomechanics and hemodynamic based on patient-specific small intracranial aneurysm using fluid-structure interaction
    Ma, Zijian
    Zhuang, Yijie
    Long, Xiaoao
    Yu, Bo
    Li, Jiawang
    Yang, Yan
    Yu, Yingxin
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2024, 244
  • [40] A patient-specific fluid-structure interaction model of the cerebrovascular damage in relation to traumatic brain injury
    Razaghi, Reza
    Biglari, Hasan
    Karimi, Alireza
    [J]. TRAUMA-ENGLAND, 2021, 23 (01): : 33 - 43