Monolithic CAD-CAM lithium disilicate versus monolithic CAD-CAM zirconia for single implant-supported posterior crowns using a digital workflow: A 3-year cross-sectional retrospective study

被引:57
作者
De Angelis, Paolo [1 ]
Passarelli, Pier Carmine [2 ]
Gasparini, Giulio [1 ]
Boniello, Roberto [1 ]
D'Amato, Giuseppe [1 ]
De Angelis, Silvio
机构
[1] Univ Cattolica Sacro Cuore, Dept Oral & Maxillofacial Surg, Med Sch, Rome, Italy
[2] Univ Cattolica Sacro Cuore, Dept Oral Surg, Med Sch, Rome, Italy
关键词
FIXED PARTIAL DENTURES; CLINICAL-OUTCOMES; FOLLOW-UP; ENAMEL; WEAR; RESTORATIONS; OCCLUSION; ANTERIOR;
D O I
10.1016/j.prosdent.2018.11.016
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of Problem. Dentistry has evolved significantly with the introduction of digital technologies and materials; however, clinical evidence for the performance of the complete digital workflow for single implant-supported posterior crowns is lacking. Purpose. The purpose of this cross-sectional retrospective clinical study was to compare the clinical outcomes of 2 types of implant-supported crown used to replace a single missing posterior tooth in a completely digital workflow: transocclusal screw-retained monolithic lithium disilicate crowns versus transocclusal screw-retained monolithic zirconia crowns. Material and methods. A total of 38 participants who had been provided with dental implants and transocclusal screw-retained monolithic lithium disilicate or zirconia single crowns were evaluated in the study. Clinical and esthetic outcomes were recorded after a 3-year follow-up. Results. Both groups had comparable clinical outcomes with a survival rate of 100%. In the lithium disilicate group, 89% of the participants were free of technical complications, and 95%, in the zirconia group. Only 1 patient experienced minor chipping affecting a lithium disilicate crown. All complications were considered minor and were easily resolved, and none of the participants required replacement of a crown. No biological complications were recorded in either group. Conclusion. Within the limitations of this cross-sectional retrospective clinical study, monolithic lithium disilicate and zirconia screw-retained single crowns fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) and a fully digital workflow were found to be reliable and suitable clinical options for restoring a posterior missing tooth on a dental implant.
引用
收藏
页码:252 / 256
页数:5
相关论文
共 25 条
[1]   Advancements in CAD/CAM technology: Options for practical implementation [J].
Alghazzawi, Tariq F. .
JOURNAL OF PROSTHODONTIC RESEARCH, 2016, 60 (02) :72-84
[2]   CLINICAL OUTCOMES OF THREE DIFFERENT CROWN SYSTEMS WITH CAD/CAM TECHNOLOGY [J].
Batson, Emily R. ;
Cooper, Lyndon F. ;
Duqum, Ibrahim ;
Mendonca, Gustavo .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (04) :770-777
[3]  
Belser UC, 2009, J PERIODONTOL, V80, P140, DOI [10.1902/jop.2009.080435, 10.1902/jop.2009.080435 ]
[4]   Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of function [J].
Brägger, U ;
Aeschlimann, S ;
Bürgin, W ;
Hämmerle, CHF ;
Lang, NP .
CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (01) :26-34
[5]  
Esquivel-Upshaw JF, 2006, INT J PROSTHODONT, V19, P391
[6]   Clinical Evaluation of 860 Anterior and Posterior Lithium Disilicate Restorations: Retrospective Study with a Mean Follow-up of 3 Years and a Maximum Observational Period of 6 Years [J].
Fabbri, Giacomo ;
Zarone, Fernando ;
Dellificorelli, Gianluca ;
Cannistraro, Giorgio ;
De Lorenzi, Marco ;
Mosca, Alberto ;
Sorrentino, Roberto .
INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2014, 34 (02) :165-177
[7]   Clinical results of lithium-disilicate crowns after up to 9 years of service [J].
Gehrt, Maren ;
Wolfart, Stefan ;
Rafai, Nicole ;
Reich, Sven ;
Edelhoff, Daniel .
CLINICAL ORAL INVESTIGATIONS, 2013, 17 (01) :275-284
[8]   Tooth wear against ceramic crowns in posterior region: a systematic literature review [J].
Hmaidouch, Rim ;
Weigl, Paul .
INTERNATIONAL JOURNAL OF ORAL SCIENCE, 2013, 5 (04) :183-190
[9]  
Hussien ANM, 2016, J PROSTHET DENT, V116, P214, DOI 10.1016/j.prosdent.2015.12.016
[10]   The complete digital workflow in fixed prosthodontics: a systematic review [J].
Joda, Tim ;
Zarone, Fernando ;
Ferrari, Marco .
BMC ORAL HEALTH, 2017, 17