Pre compression ring;
toroidal field magnet;
ITER;
FEM;
UNIDIRECTIONAL FIBERGLASS;
D O I:
10.1109/tasc.2020.2966158
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
The Pre Compression Ring (PCR) system is a key component of ITER magnetic system that radially constraints the Toroidal Field (TF) coils against the out of plane magnetic forces. Due to its peculiar characteristics (one of a kind component, unidirectional S2 fiberglass in epoxy matrix) an experimental campaign has been planned on both reduced and full scale specimens. The tests purpose is the validation of the manufacturing technique verifying the compliance with the structural requirements. The Pre Compression Ring Test Facility (PCRTF) aims at reproducing the loading condition whom the PCR is subjected to in the tokamak assembly with a safety margin. For this purpose a detailed non linear 3D FEM model was developed permitting the simulation of the tests to be performed of the full scale PCR and on two different reduced PCR sub-assemblies. The analyses permitted to assess not only the stress field inside the specimens themselves but also the stress, displacements and global forces fir the modules of the testing rig. This led to a fine optimization of the PCRTF components also investigation several off-design scenarios that may occur during the assembly and the operation of the facility.