Influence of Different Irrigation Solutions and Instrumentation Techniques on the Amount of Apically Extruded Debris

被引:7
作者
Maggi Silveira, Camila Maia [1 ]
Pimpao, Marcelo Voss [1 ]
Fernandes, Leonardo Alexandre [1 ]
Ditzel Westphalen, Vania Portela [1 ]
Cavenago, Bruno Cavalini [2 ]
Carneiro, Everdan [1 ]
机构
[1] Pontificia Univ Catolica Parana, Dept Endodont, Curitiba, Parana, Brazil
[2] Univ Fed Parana, Dept Endodont, Curitiba, Parana, Brazil
来源
EUROPEAN ENDODONTIC JOURNAL | 2019年 / 4卷 / 03期
关键词
Apical debris; apical extrusion; chlorhexidine; different techniques; sodium hypochlorite; RECIPROCATING SINGLE-FILE; FULL-SEQUENCE ROTARY; SELF-ADJUSTING FILE; PROTAPER UNIVERSAL; EXTRUSION; DENTIN;
D O I
10.14744/eej.2019.57966
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The objective of the present study was to evaluate the influence of different irrigation solutions on the amount of extruded residues apically, varying the instrumentation technique in manual, continuous rotation, or reciprocation motions. The amounts of residue for each irrigation solution was also assessed. Methods: Two tests were performed. In the first test, 90 mandibular premolars were divided into nine groups (n=10). Each group was subjected to a different technique: ProTaper Universal, WaveOne Gold, or manual instruments, with different irrigation solutions [2.5% sodium hypochlorite (NaOCl), 2% chlorhexidine (CHX) gel, or distilled water]. During the preparation of the root canal, the apically extruded material was collected in previously weighed glass vials. In the second test, irrigation solutions were weighed separately with the same weighing method. Data were analyzed using the Kolmogorov-Smirnov, one-way and two-way ANOVA, Levene, Tukey, and Games-Howell tests. Results: Apically extruded debris was observed in all groups. ProTaper Universal with continuous rotation using 2% CHX gel resulted in the greatest amount of debris (P<0.001). There were significant differences in the amounts of residue among the different groups (P<0.001). Moreover, when the weighing of the irrigation solutions was tested, the 2.5% NaOCl solution produced the greatest amount of residues compared with other irrigation solutions. Conclusion: Different irrigation solutions influenced the amount of apically extruded debris during the preparation of the canal among the different instrumentation techniques. The ProTaper technique using 2% CHX gel resulted in the greatest amount of apically extruded debris.
引用
收藏
页码:122 / 126
页数:5
相关论文
共 25 条
  • [1] Barbosa-Ribeiro Marlos, 2018, Braz. Dent. J., V29, P184, DOI 10.1590/0103-6440201801750
  • [2] The Effect of Needle-insertion Depth on the Irrigant Flow in the Root Canal: Evaluation Using an Unsteady Computational Fluid Dynamics Model
    Boutsioukis, Christos
    Lambrianidis, Theodor
    Verhaagen, Bram
    Versluis, Michel
    Kastrinakis, Eleftherios
    Wesselink, Paul R.
    van der Sluis, Lucas W. M.
    [J]. JOURNAL OF ENDODONTICS, 2010, 36 (10) : 1664 - 1668
  • [3] Apically Extruded Debris with Reciprocating Single-File and Full-sequence Rotary Instrumentation Systems
    Buerklein, Sebastian
    Schaefer, Edgar
    [J]. JOURNAL OF ENDODONTICS, 2012, 38 (06) : 850 - 852
  • [4] An In Vitro Comparison of Apically Extruded Debris and Instrumentation Times with ProTaper Universal, ProTaper Next, Twisted File Adaptive, and HyFlex Instruments
    Capar, Ismail Davut
    Arslan, Hakan
    Akcay, Merve
    Ertas, Huseyin
    [J]. JOURNAL OF ENDODONTICS, 2014, 40 (10) : 1638 - 1641
  • [5] The influence of two reciprocating single-file and two rotary-file systems on the apical extrusion of debris and its biological relationship with symptomatic apical periodontitis. A systematic review and meta-analysis
    Caviedes-Bucheli, J.
    Castellanos, F.
    Vasquez, N.
    Ulate, E.
    Munoz, H. R.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (03) : 255 - 270
  • [6] Corrêa Nágila Maluf, 2005, Rev. Bras. Cienc. Farm., V41, P73, DOI 10.1590/S1516-93322005000100008
  • [7] Apically extruded dentin debris by reciprocating single-file and multi-file rotary system
    De-Deus, Gustavo
    Neves, Aline
    Silva, Emmanuel Joao
    Mendonca, Thais Accorsi
    Lourenco, Caroline
    Calixto, Camila
    Moreira Lima, Edson Jorge
    [J]. CLINICAL ORAL INVESTIGATIONS, 2015, 19 (02) : 357 - 361
  • [8] Assessment of Apically Extruded Debris Produced by the Self-Adjusting File System
    De-Deus, Gustavo Andre
    Nogueira Leal Silva, Emmanuel Joao
    Moreira, Edson Jorge
    Neves, Aline de Almeida
    Belladonna, Felipe Goncalves
    Tameirao, Michele
    [J]. JOURNAL OF ENDODONTICS, 2014, 40 (04) : 526 - 529
  • [9] Friedman Shimon, 2004, J Calif Dent Assoc, V32, P493
  • [10] Gambarini G, 2017, CLIN TER, V168, P23, DOI 10.7417/CT.2017.1977