A stability evaluation of a novel titanium dental implant/interconnected porous hydroxyapatite complex under functional loading conditions

被引:5
作者
Doi, Kazuya [1 ]
Kubo, Takayasu [1 ]
Kajihara, Shiho [1 ]
Makihara, Yusuke [1 ]
Oue, Hiroshi [1 ]
Oki, Yoshifumi [1 ]
Perrotti, Vittoria [2 ]
Piattelli, Adriano [2 ]
Akagawa, Yasumasa [1 ]
Tsuga, Kazuhiro [1 ]
机构
[1] Hiroshima Univ, Grad Sch Biomed & Hlth Sci, Dept Adv Prosthodont, Minami Ku, 1-2-3 Kasumi, Hiroshima 7348553, Japan
[2] Chieti Pescara Univ, Dept Med Oral & Biotechnol Sci, Chieti Via Vestini 31, Chieti, Italy
关键词
Bone to implant contact; Functional loading; Histology; Implant stability; RESONANCE FREQUENCY-ANALYSIS; IMPLANT OSSEOINTEGRATION; BONE-GRAFT; AUGMENTATION; INTERFACE; CERAMICS; FLOOR; DOGS;
D O I
10.4012/dmj.2016-346
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to evaluate the stability of implant/interconnected porous calcium hydroxyapatite complex (implant/IP-CHA-complex) under functional loading. Implant/IP-CHA-complexes were placed into the mandibles of four Beagle-Labrador hybrid dogs (complex-group). On the other side, an implant was placed directly (control-group). To subject the loading, the animals were fed a hard diet throughout the loading phase of 5 months. The implant stability quotients (ISQs) and bone implant contact (BIC), and histological evaluations were performed. The ISQs of implant/IP-CHA-complex was significantly lower at placement than that of the control-implant. On the other hand, there was no significant difference between in the groups during loading. The BIC measurements, there was no significantly difference between in both groups. Histologically, newly formed bone was observed in contact with most of the implant surface in the complex-group. An IP-CHA/implant-complex would be able to achieve both bone reconstruction and implant stability under functional loading conditions.
引用
收藏
页码:647 / 653
页数:7
相关论文
共 25 条
[1]  
Al-Nawas B, 2006, INT J ORAL MAX IMPL, V21, P726
[2]  
ANDERSON HC, 1995, CLIN ORTHOP RELAT R, P266
[3]   Influence on early osseointegration of dental implants installed with two different drilling protocols: a histomorphometric study in rabbit [J].
Blanco, Juan ;
Alvarez, Elena ;
Munoz, Fernando ;
Linares, Antonio ;
Cantalapiedra, Antonio .
CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (01) :92-99
[4]  
Branemark PI., 1985, TISSUE INTEGRATED PR, P11
[5]   Healing outcomes at implants installed in grafted sites: an experimental study in dogs [J].
De Santis, Enzo ;
Lang, Niklaus P. ;
Scala, Alessandro ;
Vigano, Paolo ;
Salata, Luiz A. ;
Botticelli, Daniele .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (03) :340-350
[6]   Inorganic polyphosphate adsorbed onto hydroxyapatite for guided bone regeneration: An animal study [J].
Doi, Kazuya ;
Kubo, Takayasu ;
Takeshita, Ryou ;
Kajihara, Shiho ;
Kato, Shinichi ;
Kawazoe, Yumi ;
Shiba, Toshikazu ;
Akagawa, Yasumasa .
DENTAL MATERIALS JOURNAL, 2014, 33 (02) :179-186
[7]   The influence of fixation in formalin on the measurement of stability of implants using resonance frequency analysis and Periotest M®: A study in a dog [J].
Doi, Kazuya ;
Kajihara, Shiho ;
Morita, Koji ;
Makihara, Yusuke ;
Okada, Shinsuke ;
Akagawa, Yasumasa .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2014, 52 (01) :29-33
[8]   Development of Implant/Interconnected Porous Hydroxyapatite Complex as New Concept Graft Material [J].
Doi, Kazuya ;
Oue, Hiroshi ;
Morita, Koji ;
Kajihara, Shiho ;
Kubo, Takayasu ;
Koretake, Katsunori ;
Perrotti, Vittoria ;
Iezzi, Giovanna ;
Piattelli, Adriano ;
Akagawa, Yasumasa .
PLOS ONE, 2012, 7 (11)
[9]   Effects of Early Functional Loading on Maintenance of Free Autogenous Bone Graft and Implant Osseointegration: An Experimental Study in Dogs [J].
Faria, Paulo E. P. ;
Carvalho, Alexandre L. ;
de Torres, Erica M. ;
Rasmusson, Lars ;
Salata, Luiz A. .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (04) :825-832
[10]  
Friberg B, 1999, INT J ORAL MAX SURG, V28, P266, DOI 10.1016/S0901-5027(99)80156-8