Intra-aortic balloon counterpulsation pump in heart failure patients during MitraClip implantation-A propensity-score matched analysis

被引:5
|
作者
Kessler, Mirjam [1 ]
Seeger, Julia [1 ]
Woehrle, Jochen [1 ]
Rottbauer, Wolfgang [1 ]
Markovic, Sinisa [1 ]
机构
[1] Univ Ulm, Dept Internal Med 2, Ulm, Germany
关键词
Heart failure; IABP; MitraClip; TO-EDGE REPAIR; CORONARY INTERVENTION; MYOCARDIAL-INFARCTION; PERCUTANEOUS REPAIR; VALVE REPAIR; REGURGITATION; THERAPY; TRIAL; INDUCTION; SURGERY;
D O I
10.1002/ccd.27717
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives To analyze 30-day and 6-month results after percutaneous mitral valve repair using an IABP as circulatory support. Background The use of intra-aortic balloon counterpulsation pump extended the spectrum of cardiovascular interventions. Methods Since 2014, 17 patients of 365 patients (4.7%) at our center received an IABP during MitraClip implantation procedure. We compare the periprocedural results to a control group of 17 patients treated with MitraClip without an IABP support. To adjust for differences of baseline characteristics a propensity-score matching for age, baseline blood pressure, preoperative EuroSCORE II and left ventricular ejection fraction was performed. The decision for prophylactic implantation of an IABP was at the discretion of the interventionalist. For both groups, clinical results up to 6 months were evaluated. Results The IABP group had higher NT-pro BNP levels at baseline and increased left ventricular diameters. The procedure was more often categorized as "urgent" due to refractory heart failure in the IABP group. All procedures were carried out successfully, thereby achieving a sufficient MR reduction in both groups. Length of hospital stay was significantly longer in the IABP group 11.7 +/- 14 days (compared to 6.5 +/- 2.9 days in the No IABP group, P < 0.01). All patients in both groups had an event-free 30-day follow-up. MACCE rate was higher in the IABP group compared to the No IABP group (47.1% vs. 23.5%, P = 0.14). Conclusion Insertion of an IABP during MitraClip procedure might be a feasible option to achieve comparable results and may provide additional safety and procedural hemodynamic stability in the setting of high-risk percutaneous mitral valve repair.
引用
收藏
页码:1433 / 1438
页数:6
相关论文
共 50 条
  • [41] The effectiveness of intra-aortic balloon pump for myocardial infarction in patients with or without cardiogenic shock: a meta-analysis and systematic review
    Xiao-yun Zheng
    Yi Wang
    Yi Chen
    Xi Wang
    Lei Chen
    Jun Li
    Zhi-gang Zheng
    BMC Cardiovascular Disorders, 16
  • [42] Support with intra-aortic balloon pump vs. Impella2.5® and blood flow to the heart, brain and kidneys - An experimental porcine model of ischaemic heart failure
    Moller-Helgestad, Ole K.
    Poulsen, Christian B.
    Christiansen, Evald H.
    Lassen, Jens F.
    Ravn, Hanne B.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 178 : 153 - 158
  • [43] Effects of Intra-Aortic Balloon Pump on Markers of Right Ventricular Dysfunction Among End-Stage Heart Failure Patients Candidates to Cardiac Transplant or Ventricular Assist Device
    Damiano, Simona
    Russo, Filippo
    Campana, Carlo
    Ghio, Stefano
    Pellegrini, Carlo
    Vigano, Mario
    De Ferrari, Gaetano M.
    CIRCULATION, 2011, 124 (21)
  • [44] Waitlist and post-transplant outcomes in patients listed with intra-aortic balloon pump for heart transplant: United Network for Organ Sharing registry
    Duran, Antonio
    Nguyen, Duc T.
    Graviss, Edward A.
    Bhimaraj, Arvind
    Trachtenberg, Barry
    Hussain, Imad
    Park, Muyng
    Estep, Jerry D.
    Suarez, Eric E.
    Guha, Ashrith
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2020, 43 (09) : 606 - 613
  • [45] Mortality rate of intra-aortic balloon pump patients underwent heart valve surgery in adult ICU National Cardiovascular Heart Center Hospital, Jakarta, Indonesia
    Rachmaniah, D.
    Laitupa, F. S.
    Zahara, R.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2017, 19 (0E) : E29 - E29
  • [46] Clinical impact of intra-aortic balloon pump during extracorporeal life support in patients with acute myocardial infarction complicated by cardiogenic shock
    Taek Kyu Park
    Jeong Hoon Yang
    Seung-Hyuk Choi
    Young Bin Song
    Joo-Yong Hahn
    Jin-Ho Choi
    Kiick Sung
    Young Tak Lee
    Hyeon-Cheol Gwon
    BMC Anesthesiology, 14
  • [47] Clinical impact of intra-aortic balloon pump during extracorporeal life support in patients with acute myocardial infarction complicated by cardiogenic shock
    Park, Taek Kyu
    Yang, Jeong Hoon
    Choi, Seung-Hyuk
    Bin Song, Young
    Hahn, Joo-Yong
    Choi, Jin-Ho
    Sung, Kiick
    Lee, Young Tak
    Gwon, Hyeon-Cheol
    BMC ANESTHESIOLOGY, 2014, 14
  • [48] Intra-Aortic Balloon Pump May Grant No Benefit to Improve the Mortality of Patients With Acute Myocardial Infarction in Short and Long Term An Updated Meta-Analysis
    Su, Dan
    Yan, Bin
    Guo, Litao
    Peng, Liyuan
    Wang, Xue
    Zeng, Lingfang
    Ong, HeanYee
    Wang, Gang
    MEDICINE, 2015, 94 (19)
  • [49] Intra-Aortic Balloon Pump Catheter Insertion Using a Novel Left External Iliac Artery Approach in A Case of Chronic Heart Failure Due to Dilated Cardiomyopathy
    Dziekiewicz, Miroslaw
    Banaszewski, Marek
    Kuc, Mateusz
    Stepinska, Janina
    AMERICAN JOURNAL OF CASE REPORTS, 2019, 20 : 1826 - 1829
  • [50] Central venous oxygen saturation (ScVO2) facilitates the weaning of intra-aortic balloon pump in acute heart failure related to acute myocardial infarction
    Hsin, Ho-Tsung
    Chen, Liang-Yu
    Lin, Pi-Chi
    Shieh, Jiann-Shing
    Ao, Chi-Va
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (04) : 4568 - 4570