Acoustic Radiation, Cavitation Collapses, and Dryout in a Capillary Oscillating Heat Pipe

被引:2
|
作者
Cai, Steve Q. [1 ]
机构
[1] United Technol Carrier Corp, 6304 Carrier Pkwy, Syracuse, NY 13057 USA
来源
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME | 2020年 / 142卷 / 04期
关键词
cavitation; acoustic radiation; condensation; capillary tube; oscillation heat pipe; TEMPERATURE; BUBBLES;
D O I
10.1115/1.4046263
中图分类号
O414.1 [热力学];
学科分类号
摘要
In an oscillation heat pipe (OHP), when two-phase flow oscillates to the condensation region, saturated vapor bubbles/slugs are subjected to a sudden temperature reduction or immediate subcooling. Rapid condensation ruptures vapor bubbles and generates cavitation erosions on the tube interior surface. In this article, a thorough study is performed to understand discrepancy of variation tendency between acoustic radiation and OHP temperature difference that both are operating temperature-dependent. On this basis, three temperature zones were identified: (1) low operating temperature zone with strong cavitation collapse and acoustic radiations, (2) optimal temperature zone with the minimum temperature difference and weakening cavitation collapses, and, (3) high-temperature zone where dryout and oscillation failures develop. At the optimal operating temperature, high-frequent oscillations reduce subcooling of two-phase flow, alleviating the impact of cavitation collapses and ceasing acoustic radiations. At high operating temperature, liquid surface tension dramatically reduces and dynamic contact angle significantly increases. Both the factors tend to lower the critical diameter necessary to maintain pressure difference and oscillating two-phase slug flow. When the critical diameter reduces to be less than the OHP tube diameter, liquid slugs are not able to seal the OHP capillary tubes, leading to dryout or insufficient heat and mass transfer.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Oscillating heat pipe simulation considering dryout phenomena
    Senjaya, Raffles
    Inoue, Takayoshi
    HEAT AND MASS TRANSFER, 2014, 50 (10) : 1429 - 1441
  • [2] Oscillating heat pipe simulation considering dryout phenomena
    Raffles Senjaya
    Takayoshi Inoue
    Heat and Mass Transfer, 2014, 50 : 1429 - 1441
  • [3] Experimental Study on the Heat Transfer Enhancement of Oscillating-Flow Heat Pipe by Acoustic Cavitation
    Xian, H.
    Liu, D.
    Shang, F.
    Yang, Y.
    Chen, G.
    DRYING TECHNOLOGY, 2009, 27 (04) : 542 - 547
  • [4] A conjugate heat transfer model of oscillating heat pipe dynamics, performance, and dryout
    Li, Yuxuan
    Eldredge, Jeff D.
    Lavine, Adrienne S.
    Fisher, Timothy S.
    Drolen, Bruce L.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 227
  • [5] CAVITATION CORROSIONS IN CAPILLARY PULSATING HEAT PIPE
    Cai, Steve Q.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2018, VOL 8A, 2019,
  • [6] Heat pipe dryout and temperature hysteresis in response to transient heat pulses exceeding the capillary limit
    Baraya, Kalind
    Weibel, Justin A.
    Garimella, Suresh, V
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 148
  • [7] The study on pressure oscillation and heat transfer characteristics of oscillating capillary tube heat pipe
    Jong-Soo Kim
    Ngoc Hung Bui
    Hyun-Seok Jung
    Wook-Hyun Lee
    KSME International Journal, 2003, 17 : 1533 - 1542
  • [8] The study on pressure oscillation and heat transfer characteristics of oscillating capillary tube heat pipe
    Kim, JS
    Bui, NH
    Jung, HS
    Lee, WH
    KSME INTERNATIONAL JOURNAL, 2003, 17 (10): : 1533 - 1542
  • [9] Thermodynamic Analysis of the Dryout Limit of Oscillating Heat Pipes
    Schwarz, Florian
    Danov, Vladimir
    Lodermeyer, Alexander
    Hensler, Alexander
    Becker, Stefan
    ENERGIES, 2020, 13 (23)
  • [10] Acoustic cavitation and capillary bleeding
    不详
    ULTRASCHALL IN DER MEDIZIN, 1999, 20 (03): : 124 - 125