Investigation of the isotopic composition of lead and of trace elements concentrations in natural uranium materials as a signature in nuclear forensics

被引:42
作者
Svedkauskaite-LeGore, J.
Mayer, K.
Millet, S.
Nicholl, A.
Rasmussen, G.
Baltruenas, D.
机构
[1] European Commiss, Joint Res Ctr, Inst Transuranium Elements, D-76125 Karlsruhe, Germany
[2] Inst Phys, LT-02300 Vilnius, Lithuania
关键词
lead isotopic composition; nuclear forensics; uranium ore; yellow cake;
D O I
10.1524/ract.2007.95.10.601
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Lead is contained as trace element in uranium ores and propagates throughout the production process to intermediate products like yellow cake or uranium oxide. The lead isotopes in such material originate from two sources: natural lead and radiogenic lead. The variability of the isotopic composition of lead in ores and yellow cakes was studied and the applicability of this parameter for nuclear forensic investigations was investigated. Furthermore, the chemical impurities contained in these materials were measured in order to identify characteristic differences between materials from different mines. For the samples investigated, it could be shown, that the lead isotopic composition varies largely from mine to mine and it may be used as one of the parameters to distinguish between materials of different origins. Some of the chemical impurities show a similar pattern and support the conclusions drawn from the lead isotope data.
引用
收藏
页码:601 / 605
页数:5
相关论文
共 9 条
[1]   A new variable dispersion double-focusing plasma mass spectrometer with performance illustrated for Pb isotopes [J].
Belshaw, NS ;
Freedman, PA ;
O'Nions, RK ;
Frank, M ;
Guo, Y .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 181 :51-58
[2]   The lead isotopic composition of dust in the vicinity of a uranium mine in northern Australia and its use for radiation dose assessment [J].
Bollhofer, Andreas ;
Honeybun, Russell ;
Rosman, Kevin ;
Martin, Paul .
SCIENCE OF THE TOTAL ENVIRONMENT, 2006, 366 (2-3) :579-589
[3]  
CHOW TJ, 1975, P IAEA SM 191 4, P95
[4]  
GARCIAALONSO JI, 1993, J ANAL ATOM SPECTROM, V8, P673
[5]  
GILL R, 1997, MODERN ANAL GEOCHEMI, P344
[6]   Accuracy and long-term reproducibility of lead isotopic measurements by multiple-collector inductively coupled plasma mass spectrometry using an external method for correction of mass discrimination [J].
Rehkämper, M ;
Halliday, AN .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 181 :123-133
[7]   Investigation of matrix effects for Pb isotope ratio measurements by multiple collector ICP-MS:: verification and application of optimized analytical protocols [J].
Rehkämper, M ;
Mezger, K .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (11) :1451-1460
[8]   Isotopic compositions of the elements 1997 [J].
Rosman, KJR ;
Taylor, PDP .
PURE AND APPLIED CHEMISTRY, 1998, 70 (01) :217-235
[9]  
TATSUMOTO M, 1973, SCIENCE, V180, P1278