The Anomaly Power Transmission and Analysis at a 500kV GIS Substation

被引:0
|
作者
Qi Geqing [1 ]
Wu Gang [1 ]
Qi Zhuang [1 ]
Meng Fanlong [1 ]
Jin Daxin [1 ]
Zhang Wei [1 ]
Zhang Nan [1 ]
Wang Lulu [1 ]
机构
[1] State Gird Dalian Elect Power Supply Co, Dalian, Liaoning, Peoples R China
关键词
D O I
10.1088/1757-899X/224/1/012034
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In view of the extension which steps up from 220kV to 500kV at the switching station, induced the flashover of insulation spacer in gas chamber from 500kV line side, the voltage fault of 500kV bus, the discharge of junction which between oil-gas casing of 500kV main transformer from 220kV bus side and GIS branch bus, due to improper installation. The paper analyzes connection diagram, graph of fault recorder and repair with disassembly point for point. It also suggests the recommendations for improvement, to avoid the appearance.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Fracture failure analysis of conductive arm spring of isolation switch in 500kV substation
    Wang, Jun
    Liu, Yungen
    Chen, Junjun
    Huang, Rong
    Cao, Xianhui
    Feng, Chao
    2020 5TH INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY AND ENVIRONMENTAL PROTECTION, 2020, 621
  • [22] Analysis of the potential distribution in a relaycell generated by a direct lightning strike in a 500kV substation
    Wu, ML
    Cui, X
    Zhang, ZY
    2002 3RD INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, 2002, : 198 - 201
  • [23] Innovative Analysis and Seismic Retrofit of 500kV Flexible Bus Substation Support Structures
    Howard, Scott
    Riker, Craig
    Knight, Brian
    Knoles, Sarah
    ELECTRICAL TRANSMISSION AND SUBSTATION STRUCTURES 2015: TECHNICAL CHALLENGES AND INNOVATIVE SOLUTIONS IN GRID MODERNIZATION, 2015, : 438 - 451
  • [24] Measurement and analysis of power frequency electric field in a 500 kV substation
    School of Electrical Engineering, Shandong University, Jinan 250061, China
    Gaodianya Jishu, 2006, 11 (81-83+122):
  • [25] Selection of Protection Scheme Against Lightning Impulse Waves Based on Chaos Theory for 500kV GIS Substation
    Li Yi
    Zhou Lixing
    INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION, VOL 1, PROCEEDINGS, 2008, : 1130 - 1134
  • [26] 西藏地区500kV变电站500kV GIS室尺寸选择研究
    蔡荣根
    通讯世界, 2017, (04) : 155 - 156
  • [27] 500kV H-GIS的应用
    陈瑞壁
    张劲松
    广东输电与变电技术, 2004, (05) : 15 - 17
  • [28] Analysis Report of A Phase CVT Fault in 220kV Auxiliary Section I of 500kV Substation
    Yu Bing
    Yang Zhi
    Zhou Luyao
    Zhao Lin
    Lin Haofan
    Yang Yong
    2021 THE 6TH INTERNATIONAL CONFERENCE ON INTEGRATED CIRCUITS AND MICROSYSTEMS (ICICM 2021), 2021, : 376 - 379
  • [29] Research on the Motion System of the Inspection Robot for 500kV Power Transmission Lines
    Fang, L. J.
    Wang, H. G.
    2010 1ST INTERNATIONAL CONFERENCE ON APPLIED ROBOTICS FOR THE POWER INDUSTRY, 2010,
  • [30] Study of Configuration and Simulation Test on 220kV Reserve Power Source Automatic Connection in 500kV Substation of Shanghai Power Grid
    Zou Xiaofeng
    Zhou Desheng
    Zeng Ping
    2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,