Column selectivity in reversed-phase liquid chromatography - IV. Type-B alkyl-silica columns

被引:147
|
作者
Gilroy, JJ [1 ]
Dolan, JW [1 ]
Snyder, LR [1 ]
机构
[1] LC Resources Inc, McMinnville, OR 97128 USA
基金
美国国家卫生研究院;
关键词
column selectivity; selectivity; stationary phases; LC; alkyl-silica columns; type B; hydrophobicity; steric selectivity; hydrogen bond acidity; hydrogen bond basicity; cation-exchange behavior;
D O I
10.1016/S0021-9673(03)00512-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Columns for reversed-phase HPLC (RP-LC) can be characterized by five, retention-related parameters: H (hydrophobicity), S (steric selectivity), A (hydrogen-bond acidity), B (hydrogen-bond basicity), and C (cation-exchange behavior). In the present study, values of the latter parameters have been measured for 92 type-B (low metals content) alkyl-silica columns and compared to column properties such as ligand length, ligand concentration, pore diameter, and the presence or absence of end-capping. With the exception of five columns of unusual design, retention factors, k, for 16 representative test compounds were correlated with values of H, S, etc., within an average +/-1.2% (1 standard deviation, SD), suggesting that all significant solute-column interactions are recognized by these five column parameters. A single-valued function F is proposed to measure differences in selectivity for any two RP-LC columns whose values of H, S, etc., are known. This allows the easy selection of columns whose selectivity is desired to be either similar to or different from a starting column, for application in either routine analysis or method development. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:757 / 778
页数:22
相关论文
共 50 条
  • [41] Reversed-phase liquid chromatography of proteins and peptides using multimodal copolymer-encapsulated silica
    Shen, YF
    Shao, ZW
    O'Neill, K
    Bradshaw, JS
    Lee, ML
    JOURNAL OF CHROMATOGRAPHY A, 2000, 866 (01) : 1 - 14
  • [42] Characterisation of reversed-phase liquid chromatographic columns by chromatographic tests -: Rational column classification by a minimal number of column test parameters
    Visky, D
    Vander Heyden, B
    Iványi, T
    Baten, P
    De Beer, J
    Kovács, Z
    Noszál, B
    Dehouck, P
    Roets, E
    Massart, DL
    Hoogmartens, J
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1012 (01) : 11 - 29
  • [43] SOLVENT STRENGTH, SELECTIVITY AND RETENTION MECHANISM STUDIES ON POLYBUTADIENE-COATED ALUMINA COLUMNS IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    ARENAS, RV
    FOLEY, JP
    ANALYTICA CHIMICA ACTA, 1991, 246 (01) : 113 - 130
  • [44] Testing of "special base" columns in reversed-phase liquid chromatography - A rational approach considering solvent effects
    Le Mapihan, K
    Vial, J
    Jardy, A
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1030 (1-2) : 135 - 147
  • [45] Selectivity differences between alkyl and polar-modified alkyl phases in reversed phase high performance liquid chromatography
    Jing, Lin-Lin
    Jiang, Ru
    Liu, Peng
    Wang, Ping-An
    Shi, Tian-Yao
    Sun, Xiao-Li
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (02) : 212 - 220
  • [46] Stability of silica-based, endcapped columns with pH 7 and 11 mobile phases for reversed-phase high-performance liquid chromatography
    Kirkland, JJ
    Henderson, JW
    DeStefano, JJ
    vanStraten, MA
    Claessens, HA
    JOURNAL OF CHROMATOGRAPHY A, 1997, 762 (1-2) : 97 - 112
  • [47] Separation and characterization of octylphenol ethoxylate surfactants used by reversed-phase high-performance liquid chromatography on branched fluorinated silica gel columns
    Kamiusuki, T
    Monde, T
    Nemoto, F
    Konakahara, T
    Takahashi, Y
    JOURNAL OF CHROMATOGRAPHY A, 1999, 852 (02) : 475 - 485
  • [48] A comparison and column selection of Hydrophilic Interaction Liquid Chromatography and Reversed-Phase High-Performance Liquid Chromatography for detection of DNA methylation
    Rastegar, Leila
    Mighani, Hossein
    Ghassempour, Alireza
    ANALYTICAL BIOCHEMISTRY, 2018, 557 : 123 - 130
  • [49] High-performance liquid chromatography of basic compounds - Problems, possible solutions and tests of reversed-phase columns
    McCalley, DV
    Brereton, RG
    JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) : 407 - 420
  • [50] Optimizing selectivity during reversed-phase high performance liquid chromatography method development: Prioritizing experimental conditions
    Snyder, Lloyd R.
    Dolan, John W.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1302 : 45 - 54