Column selectivity in reversed-phase liquid chromatography - IV. Type-B alkyl-silica columns

被引:147
|
作者
Gilroy, JJ [1 ]
Dolan, JW [1 ]
Snyder, LR [1 ]
机构
[1] LC Resources Inc, McMinnville, OR 97128 USA
基金
美国国家卫生研究院;
关键词
column selectivity; selectivity; stationary phases; LC; alkyl-silica columns; type B; hydrophobicity; steric selectivity; hydrogen bond acidity; hydrogen bond basicity; cation-exchange behavior;
D O I
10.1016/S0021-9673(03)00512-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Columns for reversed-phase HPLC (RP-LC) can be characterized by five, retention-related parameters: H (hydrophobicity), S (steric selectivity), A (hydrogen-bond acidity), B (hydrogen-bond basicity), and C (cation-exchange behavior). In the present study, values of the latter parameters have been measured for 92 type-B (low metals content) alkyl-silica columns and compared to column properties such as ligand length, ligand concentration, pore diameter, and the presence or absence of end-capping. With the exception of five columns of unusual design, retention factors, k, for 16 representative test compounds were correlated with values of H, S, etc., within an average +/-1.2% (1 standard deviation, SD), suggesting that all significant solute-column interactions are recognized by these five column parameters. A single-valued function F is proposed to measure differences in selectivity for any two RP-LC columns whose values of H, S, etc., are known. This allows the easy selection of columns whose selectivity is desired to be either similar to or different from a starting column, for application in either routine analysis or method development. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:757 / 778
页数:22
相关论文
共 50 条
  • [21] Preparation and Chromatographic Evaluation of Columns for Reversed-Phase Liquid Chromatography
    Zhang, Mengyao
    Wang, Haibo
    Chen, Hui
    Sun, Xiaoli
    Jiang, Ru
    ACTA CHIMICA SLOVENICA, 2011, 58 (01) : 60 - 68
  • [22] Effect of buffers on silica-based column stability in reversed-phase high-performance liquid chromatography
    Claessens, HA
    vanStraten, MA
    Kirkland, JJ
    JOURNAL OF CHROMATOGRAPHY A, 1996, 728 (1-2) : 259 - 270
  • [23] Development and validation of an improved method for the analysis of vancomycin by liquid chromatography - Selectivity of reversed-phase columns towards vancomycin components
    Diana, J
    Visky, D
    Roets, E
    Hoogmartens, J
    JOURNAL OF CHROMATOGRAPHY A, 2003, 996 (1-2) : 115 - 131
  • [24] Column preparation for reversed-phase high-temperature open tubular column liquid chromatography
    Nyholm, LM
    Markides, KE
    JOURNAL OF CHROMATOGRAPHY A, 1998, 813 (01) : 11 - 20
  • [25] Selectivity comparisons of monolithic silica capillary columns modified with poly(octadecyl methacrylate) and octadecyl moieties for halogenated compounds in reversed-phase liquid chromatography
    Soonthorntantikul, Wasura
    Leepipatpiboon, Natchanun
    Ikegami, Tohru
    Tanaka, Nobuo
    Nhujak, Thumnoon
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (31) : 5868 - 5874
  • [26] Monitoring aged reversed-phase high performance liquid chromatography columns
    Bolck, A
    Smilde, AK
    Bruins, CHP
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 46 (01) : 1 - 12
  • [27] Influence of the modification conditions of alkyl bonded ligands on the characteristics of reversed-phase liquid chromatography
    Miyabe, K
    Guiochon, G
    JOURNAL OF CHROMATOGRAPHY A, 2000, 903 (1-2) : 1 - 12
  • [28] Reversed-phase liquid chromatography column testing: robustness study of the test
    Le Mapihan, K
    Vial, J
    Jardy, A
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1061 (02) : 149 - 158
  • [29] Retention characteristics of an immobilized artificial. membrane column in reversed-phase liquid chromatography
    Lepont, C
    Poole, CF
    JOURNAL OF CHROMATOGRAPHY A, 2002, 946 (1-2) : 107 - 124
  • [30] Variability of column selectivity for reversed-phase high-performance liquid chromatography - Compensation by adjustment of separation conditions
    Dolan, JW
    Snyder, LR
    Jupille, TH
    Wilson, NS
    JOURNAL OF CHROMATOGRAPHY A, 2002, 960 (1-2) : 51 - 67