Effectiveness of continuous glucose monitoring in dialysis patients with diabetes: The DIALYDIAB pilot study

被引:68
作者
Joubert, Michael [1 ]
Fourmy, Corinne [1 ]
Henri, Patrick [2 ]
Ficheux, Maxence [2 ]
Lobbedez, Thierry [2 ]
Reznik, Yves [1 ]
机构
[1] Univ Hosp Caen, Diabet Care Unit, F-14033 Caen 9, France
[2] Univ Hosp Caen, Dialysis Unit, F-14033 Caen 9, France
关键词
Diabetes; Continuous glucose monitoring; End-stage renal disease; Hemodialysis; CHRONIC KIDNEY-DISEASE; GLYCEMIC CONTROL; MAINTENANCE HEMODIALYSIS; RENAL-FAILURE; OUTCOMES; HYPOGLYCEMIA; METABOLISM; MELLITUS; SYSTEM;
D O I
10.1016/j.diabres.2015.01.026
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The DIALYDIAB trial addresses the contribution of iterative sequences of continuous glucose monitoring (CGM) on glucose control in dialysis patients with diabetes. Materials and methods: In this before-after monocentric 12-week pilot study, dialysis patients with diabetes were monitored with self-monitoring blood glucose (SMBG) 3 times per day during a 6-week period followed by a 5-day CGM recording at 2-week interval during another 6-week period. SMBG and CGM profiles were remotely analyzed by a single diabetes expert who gave therapeutic counseling to dialysis physicians. Results: Fifteen patients who entered the study had a male/female ratio 8/7, age 60.9 +/- 14.8 years, BMI 29.9 +/- 7.8, diabetes duration 19.2 +/- 8.5 years and dialysis duration 6.5 +/- 6.9 years. Treatments were diet alone (20%) or diet plus insulin (80%). Mean CGM glucose level was 8.3 +/- 2.5 mmol/l at baseline (T0), 8.2 +/- 1.6 mmol/l at the end of the SMBG period (T1) (ns) and 7.7 +/- 1.6 mmol/l at the end of the CGM period (T2) (p < 0.05 vs T0). Glucose AUC > 10 mmol/l was 0.9 +/- 1.4 mmol/l/day at T0 and decreased to 0.4 +/- 0.5 at T2 (p < 0.05)) without change in glucose AUC < 3.3 mmol/l. Treatment adaptation was higher during the CGM period (1.4 +/- 1.0 and 2.1 +/- 0.9 treatment change at T1 and T2, respectively; p < 0.05). Conclusions: In patients with diabetes on chronic dialysis, iterative CGM monitoring was associated with more frequent treatment changes and finally, better glucose control, without increased risk of hypoglycemia. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:348 / 354
页数:7
相关论文
共 24 条
[1]   Inter-relationships between renal metabolism (both in physiology and renal dysfunction) and the liver [J].
Cano, N .
CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2001, 4 (04) :279-285
[2]  
Chantrel F, 2014, HORM METAB RES
[3]   Prevalence of chronic kidney disease in the United States [J].
Coresh, Josef ;
Selvin, Elizabeth ;
Stevens, Lesley A. ;
Manzi, Jane ;
Kusek, John W. ;
Eggers, Paul ;
Van Lente, Frederick ;
Levey, Andrew S. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (17) :2038-2047
[4]   Hypoglycemia in patients with renal failure [J].
Haviv, YS ;
Sharkia, M ;
Safadi, R .
RENAL FAILURE, 2000, 22 (02) :219-223
[5]   Elderly patients with chronic kidney disease: outcomes after 5 years of follow-up [J].
Heras, Manuel ;
Jose Fernandez-Reyes, M. ;
Sanchez, Rosa ;
Teresa Guerrero, M. ;
Molina, Alvaro ;
Astrid Rodriguez, M. ;
Alvarez-Ude, Fernando .
NEFROLOGIA, 2012, 32 (03) :300-305
[6]   Glycated albumin is a better glycemic indicator than glycated hemoglobin values in hemodialysis patients with diabetes: Effect of anemia and erythropoietin injection [J].
Inaba, Masaaki ;
Okuno, Senji ;
Kumeda, Yasuro ;
Yamada, Shinsuke ;
Imanishi, Yasuo ;
Tabata, Tsutomu ;
Okamura, Mikio ;
Okada, Shigeki ;
Yamakawa, Tomoyuki ;
Ishimura, Eiji ;
Nishizawa, Yoshiki .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2007, 18 (03) :896-903
[7]  
Inzucchi SE, DIABETES CARE
[8]  
Jensen Morten Hasselstrom, 2013, J Diabetes Sci Technol, V7, P135
[9]   Long-term glycemic control measurements in diabetic patients receiving hemodialysis [J].
Joy, MS ;
Cefalu, T ;
Hogan, SL ;
Nachman, PH .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2002, 39 (02) :297-307
[10]   Analysis of Hemodialysis-Associated Hypoglycemia in Patients with Type 2 Diabetes Using a Continuous Glucose Monitoring System [J].
Jung, Hye Seung ;
Kim, Hong Il ;
Kim, Min Joo ;
Yoon, Ji Won ;
Ahn, Hwa Young ;
Cho, Young Min ;
Oh, Kook-Hwan ;
Joo, Kwon Wook ;
Lee, Jung Geon ;
Kim, Seong Yeon ;
Park, Kyong Soo .
DIABETES TECHNOLOGY & THERAPEUTICS, 2010, 12 (10) :801-807