A microchip electrophoresis-based assay for ratiometric detection of kanamycin by R-shape probe and exonuclease-assisted signal amplification

被引:25
作者
Chen, Xixue [1 ]
Hong, Feng [1 ]
Cao, Yuting [1 ]
Hu, Futao [2 ]
Wu, Yongxiang [1 ]
Wu, Dazhen [1 ]
Li, Tianhua [1 ]
Lin, Jianyuan [3 ]
Gan, Ning [1 ]
机构
[1] Ningbo Univ, Fac Mat Sci & Chem Engn, Ningbo 315211, Zhejiang, Peoples R China
[2] Ningbo Univ, Fac Marine, Ningbo 315211, Zhejiang, Peoples R China
[3] Zhejiang Wanli Univ, Ningbo 31521, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Microchip electrophoresis; R-DNA probe; Ratiometric assay; Exonuclease I; Signal amplification; Antibiotics residues; SYBR-GREEN-I; CAPILLARY-ELECTROPHORESIS; FLUORESCENCE DETECTION; AMINOGLYCOSIDE ANTIBIOTICS; COLORIMETRIC DETECTION; SENSITIVE DETECTION; MILK SAMPLES; LABEL-FREE; APTAMER; DNA;
D O I
10.1016/j.talanta.2018.07.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Excessive intake of kanamycin (KANA) can cause some serious drug-resistant diseases, so it is urgent to develop some accurate and rapid analytical methods for monitor KANA residues in foodstuffs with complex matrix. Recently, many ratiometric assays were reported to be capable of overcoming matrix interference. Herein, a ratiometric and homogeneous assay for KANA detection based on microchip electrophoresis (MCE) was developed. First, by one single strand DNA (S-DNA) and one hairpin DNA (H-DNA), a novel R shape DNA probe (R DNA) was prepared. After the probe was incubated with KANA, the S-DNA-KANA complex was formed, and H-DNA was released. Moreover, in the presence of exonuclease I (Exo-I), S-DNA-KANA complex would be digested to release the captured KANA for triggering target recycling and signal amplification. With the reaction going on, the fluorescence intensity of H-DNA (I-H) increased and that of R-DNA (I-R) decreased. They can be separated at different voltage intensities and converted to fluorescent signals for signal readout by MCE. The signal ratio of I-H/I-R was found to be linear toward target from 0.5 pg mL(-1) to 10 ng mL(-1), and the limit of detection was 150 fg mL(-1). Moreover, it was successfully employed for KANA detection in milk and fish samples with consistent results of enzyme linked immune sorbent assay (ELISA). The R-DNA probe can quantitatively convert the amount of target to the intensity of DNA without label by MCE, and achieved exonuclease assisted signal amplification in homogenous solution. It was valuable to detect antibiotics residues in foodstuff with complex matrix. This approach broadened the application field of MCE to detect antibiotics without derivatization, which provided a promising platform for rapid screening of antibiotic residues in food.
引用
收藏
页码:494 / 501
页数:8
相关论文
共 39 条
[1]   Preparation of Antibodies and Development of an Enzyme-Linked Immunosorbent Assay (ELISA) for the Determination of Doxycycline Antibiotic in Milk Samples [J].
Adrian, Javier ;
Fernandez, Fatima ;
Sanchez-Baeza, Francisco ;
Marco, M. -Pilar .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2012, 60 (15) :3837-3846
[2]  
Carlos C. S. H., 2003, ANAL CHEM, V75, P4778
[3]   Monitoring of vancomycin in human plasma via portable microchip electrophoresis with contactless conductivity detector and multi-stacking strategy [J].
Chong, Kah Chun ;
Thang, Lee Yien ;
Quirino, Joselito P. ;
See, Hong Heng .
JOURNAL OF CHROMATOGRAPHY A, 2017, 1485 :142-146
[4]   A novel electrochemical aptasensor based on arch-shape structure of aptamer-complimentary strand conjugate and exonuclease I for sensitive detection of streptomycin [J].
Danesh, Noor Mohammad ;
Ramezani, Mohammad ;
Emrani, Ahmad Sarreshtehdar ;
Abnous, Khalil ;
Taghdisi, Seyed Mohammad .
BIOSENSORS & BIOELECTRONICS, 2016, 75 :123-128
[5]   Native fluorescence detection of biomolecular and pharmaceutical compounds in capillary electrophoresis: Detector designs, performance and applications: A review [J].
de Kort, Bregje J. ;
de Jong, Gerhardus J. ;
Somsen, Govert W. .
ANALYTICA CHIMICA ACTA, 2013, 766 :13-33
[6]   Post separation adjustment of pH to enable the analysis of aminoglycoside antibiotics by microchip electrophoresis with amperometric detection [J].
Ding, Yongsheng ;
Bai, Liang ;
Suo, Xingmei ;
Meng, Xiangying .
ELECTROPHORESIS, 2012, 33 (21) :3245-3253
[7]   Colorimetric and fluorescence quenching aptasensors for detection of streptomycin in blood serum and milk based on double-stranded DNA and gold nanoparticles [J].
Emrani, Ahmad Sarreshtehdar ;
Danesh, Noor Mohammad ;
Lavaee, Parirokh ;
Ramezani, Mohammad ;
Abnous, Khalil ;
Taghdisi, Seyed Mohammad .
FOOD CHEMISTRY, 2016, 190 :115-121
[8]   Ultrasensitive Ratiometric Homogeneous Electrochemical MicroRNA Biosensing via Target-Triggered Ru(III) Release and Redox Recycling [J].
Gai, Panpan ;
Gu, Chengcheng ;
Li, Haiyin ;
Sun, Xinzhi ;
Li, Feng .
ANALYTICAL CHEMISTRY, 2017, 89 (22) :12293-12298
[9]   Polymeric Microchip for the Simultaneous Determination of Anions and Cations by Hydrodynamic Injection Using a Dual-Channel Sequential Injection Microchip Electrophoresis System [J].
Gaudry, Adam J. ;
Nai, Yi Heng ;
Guij, Rosanne M. ;
Breadmore, Michael C. .
ANALYTICAL CHEMISTRY, 2014, 86 (07) :3380-3388
[10]   Ratiometric fluorescence and visual imaging detection of dopamine based on carbon dots/copper nanoclusters dual-emitting nanohybrids [J].
He, Weijie ;
Gui, Rijun ;
Jin, Hui ;
Wang, Benqian ;
Bu, Xiangning ;
Fu, Yongxin .
TALANTA, 2018, 178 :109-115