Clinical outcomes following awake and asleep deep brain stimulation for Parkinson disease

被引:84
作者
Chen, Tsinsue [1 ]
Mirzadeh, Zaman [1 ]
Chapple, Kristina M. [1 ]
Lambert, Margaret [1 ]
Shill, Holly A. [2 ]
Moguel-Cobos, Guillermo [2 ]
Troster, Alexander I. [3 ]
Dhall, Rohit [4 ]
Ponce, Francisco A. [1 ]
机构
[1] St Josephs Hosp, Barrow Neurol Inst, Dept Neurosurg, Phoenix, AZ USA
[2] St Josephs Hosp, Barrow Neurol Inst, Dept Neurol, Phoenix, AZ USA
[3] St Josephs Hosp, Barrow Neurol Inst, Dept Clin Neuropsychol, Phoenix, AZ USA
[4] Univ Arkansas Med Sci, Dept Neurol, Little Rock, AR 72205 USA
关键词
asleep DBS; clinical outcomes; deep brain stimulation; functional neurosurgery; general anesthesia; intraoperative imaging; levodopa equivalent daily dosage; Parkinson disease; PDQ-39; stereotactic accuracy; Unified Parkinson's Disease Rating Scale; SUBTHALAMIC NUCLEUS; GLOBUS-PALLIDUS; MEDICAL THERAPY; LEAD PLACEMENT; STN DBS; SURGERY; MRI; COMPLICATIONS; MULTICENTER; INTERNA;
D O I
10.3171/2017.8.JNS17883
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE Recent studies have shown similar clinical outcomes between Parkinson disease (PD) patients treated with deep brain stimulation (DBS) under general anesthesia without microelectrode recording (MER), so-called "asleep" DBS, and historical cohorts undergoing " awake" DBS with MER guidance. However, few studies include internal controls. This study aims to compare clinical outcomes after globus pallidus internus (GPi) and subthalamic nucleus (STN) DBS using awake and asleep techniques at a single institution. METHODS PD patients undergoing awake or asleep bilateral GPi or STN DBS were prospectively monitored. The primary outcome measure was stimulation-induced change in motor function off medication 6 months postoperatively, measured using the Unified Parkinson's Disease Rating Scale part III (UPDRS-III). Secondary outcomes included change in quality of life, measured by the 39-item Parkinson's Disease Questionnaire (PDQ-39), change in levodopa equivalent daily dosage (LEDD), stereotactic accuracy, stimulation parameters, and adverse events. RESULTS Six-month outcome data were available for 133 patients treated over 45 months (78 GPi [16 awake, 62 asleep] and 55 STN [14 awake, 41 asleep]). UPDRS-III score improvement with stimulation did not differ between awake and asleep groups for GPi (awake, 20.8 points [38.5%]; asleep, 18.8 points [37.5%]; p = 0.45) or STN (awake, 21.6 points [40.3%]; asleep, 26.1 points [48.8%]; p = 0.20) targets. The percentage improvement in PDQ-39 and LEDD was similar for awake and asleep groups for both GPi (p = 0.80 and p = 0.54, respectively) and STN cohorts (p = 0.85 and p = 0.49, respectively). CONCLUSIONS In PD patients, bilateral GPi and STN DBS using the asleep method resulted in motor, quality-of-life, and medication reduction outcomes that were comparable to those of the awake method.
引用
收藏
页码:109 / 120
页数:12
相关论文
共 35 条
[1]  
Alesch F., 2016, Neurosurgery, V63, P155, DOI [DOI 10.1227/01.NEU.0000489705.76089.C2, DOI 10.1227/01.NEU.0000489705.76089.C, 10.1227/01.neu.0000489705.76089.c]
[2]   Radiosurgery for basal gangliaf internal capsule, and thalamus arteriovenous malformation: Clinical outcome [J].
Andrade-Souza, YM ;
Zadeh, G ;
Scora, D ;
Tsao, MN ;
Schwartz, ML .
NEUROSURGERY, 2005, 56 (01) :56-63
[3]   Accuracy of deep brain stimulation electrode placement using intraoperative computed tomography without microelectrode recording Clinical article [J].
Burchiel, Kim J. ;
McCartney, Shirley ;
Lee, Albert ;
Raslan, Ahmed M. .
JOURNAL OF NEUROSURGERY, 2013, 119 (02) :301-306
[4]   "Asleep" Deep Brain Stimulation Surgery: A Critical Review of the Literature [J].
Chen, Tsinsue ;
Mirzadeh, Zaman ;
Ponce, Francisco A. .
WORLD NEUROSURGERY, 2017, 105 :191-198
[5]   Complication rates, lengths of stay, and readmission rates in "awake" and "asleep" deep brain simulation [J].
Chen, Tsinsue ;
Mirzadeh, Zaman ;
Chapple, Kristina ;
Lambert, Margaret ;
Ponce, Francisco A. .
JOURNAL OF NEUROSURGERY, 2017, 127 (02) :360-369
[6]   "Asleep" deep brain stimulation for essential tremor [J].
Chen, Tsinsue ;
Mirzadeh, Zaman ;
Chapple, Kristina ;
Lambert, Margaret ;
Dhall, Rohit ;
Ponce, Francisco A. .
JOURNAL OF NEUROSURGERY, 2016, 124 (06) :1842-1849
[7]   Risks of common complications in deep brain stimulation surgery: management and avoidance [J].
Fenoy, Albert J. ;
Simpson, Richard K., Jr. .
JOURNAL OF NEUROSURGERY, 2014, 120 (01) :132-139
[8]   Pallidal versus Subthalamic Deep-Brain Stimulation for Parkinson's Disease [J].
Follett, Kenneth A. ;
Weaver, Frances M. ;
Stern, Matthew ;
Hur, Kwan ;
Harris, Crystal L. ;
Luo, Ping ;
Marks, William J., Jr. ;
Rothlind, Johannes ;
Sagher, Oren ;
Moy, Claudia ;
Pahwa, Rajesh ;
Burchiel, Kim ;
Hogarth, Penelope ;
Lai, Eugene C. ;
Duda, John E. ;
Holloway, Kathryn ;
Samii, Ali ;
Horn, Stacy ;
Bronstein, Jeff M. ;
Stoner, Gatana ;
Starr, Philip A. ;
Simpson, Richard ;
Baltuch, Gordon ;
De Salles, Antonio ;
Huang, Grant D. ;
Reda, Domenic J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (22) :2077-2091
[9]   MRI-guided STN DBS in Parkinson's disease without microelectrode recording: efficacy and safety [J].
Foltynie, T. ;
Zrinzo, L. ;
Martinez-Torres, I. ;
Tripoliti, E. ;
Petersen, E. ;
Holl, E. ;
Aviles-Olmos, I. ;
Jahanshahi, M. ;
Hariz, M. ;
Limousin, P. .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2011, 82 (04) :358-363
[10]   Subthalamic nucleus deep brain stimulation: Summary and meta-analysis of outcomes [J].
Kleiner-Fisman, Galit ;
Herzog, Jan ;
Fisman, David N. ;
Tamma, Filippo ;
Lyons, Kelly E. ;
Pahwa, Rajesh ;
Lang, Anthony E. ;
Deuschl, Guenther .
MOVEMENT DISORDERS, 2006, 21 :S290-S304