Modelling and small-signal analysis of a grid connected doubly-fed induction generator

被引:0
|
作者
Mei, F [1 ]
Pal, BC [1 ]
机构
[1] Imperial Coll Sch Med, Dept Elect Engn, London SW7 2AZ, England
关键词
doubly-fed induction generator; non-linear dynamical model; small-signal model; eigenvalue analysis;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper describes the modeling and small signal analysis of a grid connected doubly-fed induction generator (DFIG). Different models are formulated and compared with each other for different assumptions (two or one-mass drive train, with or without stator transients). The models are developed from the basic flux linkage, voltage and torque equations. Eigenvalues and participation factor analysis of the linearized models are carried out to relate the DFIG electromechanical modes to its relevant state variables.
引用
收藏
页码:2101 / 2108
页数:8
相关论文
共 50 条
  • [21] Adaptive Backstepping Control of Grid-Connected Doubly-Fed Induction Generator during Grid Voltage Dip
    Adekanle, Oluwaseun
    Guisser, M.
    Abdelmounim, E.
    Aboulfatah, M.
    PROCEEDINGS OF 2017 INTERNATIONAL CONFERENCE ON ELECTRICAL AND INFORMATION TECHNOLOGIES (ICEIT 2017), 2017,
  • [22] Mathematical Modelling of Grid Connected Doubly Fed Induction Generator Based Wind Farm
    Mahalakshmi, R.
    Viknesh, J.
    Thampatty, K. C. Sindhu
    2016 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2016,
  • [24] Transient Analysis of Brushless Doubly-Fed Induction Generator
    Liu, Guangjun
    Wang, Xuefan
    Xiong, Fei
    2016 19TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2016), 2016,
  • [25] Analysis and control of a cascaded doubly-fed induction generator
    Patin, N
    Monmasson, E
    Louis, JP
    IECON 2005: THIRTY-FIRST ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-3, 2005, : 2487 - 2492
  • [26] Impact of Distributed Synchronous and Doubly-Fed Induction Generators on Small-Signal Stability of a Distribution Network
    de Oliveira, R. V.
    Zamadei, J. A.
    Hossi, C. H.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [27] Performance Evaluation of New Series Connected Grid-Side Converter of Doubly-Fed Induction Generator
    Singh, Bharat
    Emmoji, V.
    Singh, S. N.
    Erlich, I.
    2008 JOINT INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON) AND IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2008, : 1170 - +
  • [28] Performance Analysis of a Full Order Sensorless Control Adaptive Observer for Doubly-Fed Induction Generator in Grid Connected Operation
    Brando, Gianluca
    Dannier, Adolfo
    Spina, Ivan
    ENERGIES, 2021, 14 (05)
  • [29] Grid disturbance response of wind turbines equipped with induction generator and doubly-fed induction generator
    Thiringer, T
    Petersson, A
    Petru, T
    2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 1542 - 1547
  • [30] Resonant-based sliding mode control of doubly-fed induction generator connected to unideal grid
    Nian, H. (nianheng@zju.edu.cn), 1600, Zhejiang University (48):