Preconcentration by Coprecipitation of Copper and Nickel with Mo(VI)/Triazole Derivative System and Their Determinations by Flame Atomic Absorption Spectrometry in Food and Water Samples

被引:11
作者
Ozdes, Duygu [1 ]
Duran, Celal [1 ]
Bayrak, Hacer [1 ]
Bulut, Volkan Numan [2 ]
Tufekci, Mehmet [2 ]
机构
[1] Karadeniz Tech Univ, Dept Chem, Fac Sci, TR-61080 Trabzon, Turkey
[2] Karadeniz Tech Univ, Macka Vocat Sch, Macka Trabzon, Turkey
关键词
Coprecipitation; Di-tert-butyl{methylenebis[5-(chlorobenzyl)-4H-1; 2; 4-triazol-3; 4-diyl]}biscarbamate; Flame atomic absorption spectrometry; Preconcentration; CLOUD POINT EXTRACTION; SOLID-PHASE EXTRACTION; TRACE-METAL IONS; ENVIRONMENTAL-SAMPLES; HEAVY-METALS; SEPARATION; LEAD; HYDROXIDE; SPECIATION; CADMIUM;
D O I
10.1002/clen.201000326
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new separation and preconcentration technique based on coprecipitation of Cu(II) and Ni(II) ions by the aid of Mo(VI)/di-tert-butyl{methylenebis[5-(chlorobenzyl)-4H-1,2,4-triazol-3,4-diyl]}biscarbamate (BUMECTAC) precipitate has been established. The Mo(VI)/BUMECTAC precipitate was dissolved by concentrated HNO3 and the solution was completed to 5.0?mL with distilled/deionized water. The levels of the analyte ions were determined by flame atomic absorption spectrometer. The effects of experimental conditions like HNO3 concentration, amount of BUMECTAC and Mo(VI), sample volume, etc. and also the influences of some foreign ions were investigated in detail on the quantitative recoveries of analyte ions. The preconcentration factors were found to be 40 for Cu(II) and 100 for Ni(II) ions. The detection limits for Cu(II) and Ni(II) ions based on 3s (N:10) were 0.43 and 0.70 mu gL(-1), respectively. The relative standard deviations were found to be lower than 4.0% for both analyte ions. The accuracy of the method was checked by spiked/recovery tests and the analysis of two certified reference materials (Environment Canada TM-25.3 and CRM-SA-C Sandy Soil C). The procedure was successfully applied to sea water and stream water as liquid samples and baby food as solid sample in order to determine the levels of Cu(II) and Ni(II) ions.
引用
收藏
页码:211 / 217
页数:7
相关论文
共 32 条
[1]   Determination of cadmium in spring water by graphite-furnace atomic absorption spectrometry after coprecipitation with ytterbium hydroxide [J].
Atsumi, K ;
Minami, T ;
Ueda, J .
ANALYTICAL SCIENCES, 2005, 21 (06) :647-649
[2]   A novel multi-element coprecipitation technique for separation and enrichment of metal ions in environmental samples [J].
Aydin, Funda Armagan ;
Soylak, Mustafa .
TALANTA, 2007, 73 (01) :134-141
[3]   Synthesis and antimicrobial activities of some new 1,2,4-triazole derivatives [J].
Bayrak, Hacer ;
Demirbas, Ahmet ;
Bektas, Hakan ;
Karaoglu, Sengul Alpay ;
Demirbas, Neslihan .
TURKISH JOURNAL OF CHEMISTRY, 2010, 34 (06) :835-846
[4]   A novel slurry sampling analysis of lead in different water samples by electrothermal atomic absorption spectrometry after coprecipitated with cobalt/pyrrolidine dithiocarbamate complex [J].
Baysal, A. ;
Akman, S. ;
Calisir, F. .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 158 (2-3) :454-459
[5]   Speciation of Cr(III) and Cr(VI) after column solid phase extraction on Amberlite XAD-2010 [J].
Bulut, V. N. ;
Duran, C. ;
Tufekci, M. ;
Elci, L. ;
Soylak, M. .
JOURNAL OF HAZARDOUS MATERIALS, 2007, 143 (1-2) :112-117
[6]   Carrier element-free coprecipitation (CEFC) method for the separation, preconcentration and speciation of chromium using an isatin derivative [J].
Bulut, Volkan Numan ;
Ozdes, Duygu ;
Bekircan, Olcay ;
Gundogdu, Ali ;
Duran, Celal ;
Soylak, Mustafa .
ANALYTICA CHIMICA ACTA, 2009, 632 (01) :35-41
[7]   Flow injection on-line coprecipitation-preconcentration system using copper(II) diethyldithiocarbamate as carrier for flame atomic absorption spectrometric determination of cadmium, lead and nickel in environmental samples [J].
Chen, HW ;
Jin, JC ;
Wang, YF .
ANALYTICA CHIMICA ACTA, 1997, 353 (2-3) :181-188
[8]   Electrochemical deposition of zinc selenide and cadmium selenide onto porous silicon from aqueous acidic solutions [J].
Chubenko, E. B. ;
Klyshko, A. A. ;
Petrovich, V. A. ;
Bondarenko, V. P. .
THIN SOLID FILMS, 2009, 517 (21) :5981-5987
[9]   Separation and Preconcentration of Cobalt Using a New Schiff Base Derivative on Amberlite XAD-7 [J].
Ciftci, Harun .
CLEAN-SOIL AIR WATER, 2010, 38 (07) :657-662
[10]   Determination of copper, cadmium and lead in seawater and mineral water by flame atomic absorption spectrometry after coprecipitation with aluminum hydroxide [J].
Doner, G ;
Ege, A .
ANALYTICA CHIMICA ACTA, 2005, 547 (01) :14-17