Coil model comparison for cerebellar transcranial magnetic stimulation

被引:18
|
作者
Can, M. Kaan [1 ,2 ]
Laakso, Ilkka [1 ]
Nieminen, Jaakko O. [2 ,3 ]
Murakami, Takenobu [4 ]
Ugawa, Yoshikazu [4 ]
机构
[1] Aalto Univ, Dept Elect Engn & Automat, Espoo, Finland
[2] Aalto Univ, Dept Neurosci & Biomed Engn, Espoo, Finland
[3] Aalto Univ, Aalto TMS Lab, Aalto Neuroimaging, Espoo, Finland
[4] Fukushima Med Univ, Dept Neurol, Fukushima, Japan
来源
关键词
transcranial magnetic stimulation; magnetic coil; cerebellum; electric field; patient-specific modelling; finite-element method; ELECTRIC-FIELD; TMS; GEOMETRY; ATAXIA;
D O I
10.1088/2057-1976/aaee5b
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective. Transcranial magnetic stimulation (TMS) has been increasingly used for investigating the function of different areas of the cerebellum. Experimental studies have shown variable effectiveness of different types of coils in cerebellar TMS. Our objective is to systematically investigate the effects of coil type on the electric field (E-field) induced in the cerebellum. Approach. Induced E-fields of cerebellar TMS were modelled using individualised head models of 15 subjects. A double-cone, a figure-of-8 and a round coil were modelled, and E-field measurements were performed to validate the coil models. The E-fields induced in anatomical models are statistically analysed to investigate the effects of the coil type and placement on the stimulation strength, depth and focality. Main results. The E-field measurements showed that the applied thin-wire approximation is valid and useful for computational modelling of TMS coils. Inter-subject analysis of the induced E-fields showed that the round coil systematically produced the weakest E-fields. The difference between the double-cone and figure-of-8 coils was not systematic; instead, the most efficient coil type depended on the targeted region of the cerebellum. Further, despite inter-subject differences, the double-cone coil appeared more suitable for stimulating deeper regions of the cerebellum, whereas the figure-of-8 coil produces more focal stimulation, hence providing precise stimulation of regions closer to the scalp surface. Significance. The double-cone, round and figure-of-8 coils have different advantages over each other in different situations. The choice of the coil geometry and placement should be made with care for the desired stimulation outcome. Moreover, inter-subject anatomical differences affect the E-field induced in the cerebellum, and anatomical modelling using magnetic resonance imaging data can enhance the precision of cerebellar TMS.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] CEREBELLAR TRANSCRANIAL MAGNETIC STIMULATION IN PATIENTS WITH BIPOLAR DISORDER
    Ewald, Victoria Muller
    Trapp, Nicholas
    Boes, Aaron
    Parker, Krystal
    PSYCHOPHYSIOLOGY, 2022, 59 : S7 - S7
  • [32] Stimulation Effects Mapping for Optimizing Coil Placement for Transcranial Magnetic Stimulation
    Zhong, Gangliang
    Jin, Fang
    Ma, Liang
    Yang, Yongfeng
    Zhang, Baogui
    Cao, Dan
    Li, Jin
    Zuo, Nianming
    Fan, Lingzhong
    Yang, Zhengyi
    Jiang, Tianzi
    NEUROINFORMATICS, 2025, 23 (01)
  • [33] Comparison of the induced fields using different coil configurations during deep transcranial magnetic stimulation
    Lu, Mai
    Ueno, Shoogo
    PLOS ONE, 2017, 12 (06):
  • [34] The Comparison of Electric Fields Distribution Applying Various Coil Configurations in Deep Transcranial Magnetic Stimulation
    Wei, Xile
    Li, Yao
    Yi, Guosheng
    Lu, Meili
    Wang, Jiang
    Zhang, Zhen
    2017 10TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI), 2017,
  • [35] Effects of Cerebellar Transcranial Direct Current Stimulation on Cerebellar Brain Inhibition as a Function of TMS Coil Orientation
    Steiner, Katharina M.
    Nicksirat, Seyed Ali
    Thieme, Andreas
    Muentefering, Lara
    Ernst, Thomas M.
    Timmann, Dagmar
    Batsikadze, Giorgi
    BRAIN AND BEHAVIOR, 2025, 15 (02):
  • [36] Assessment of standard coil positioning in transcranial magnetic stimulation in depression
    Nauczyciel, Cecilia
    Hellier, Pierre
    Morandi, Xavier
    Blestel, Sophie
    Drapier, Dominique
    Ferre, Jean Christophe
    Barillot, Christian
    Millet, Bruno
    PSYCHIATRY RESEARCH, 2011, 186 (2-3) : 232 - 238
  • [37] Modelling of Deep Transcranial Magnetic Stimulation: Different Coil Configurations
    Guadagnin, V.
    Parazzini, M.
    Liorni, I.
    Fiocchi, S.
    Ravazzani, P.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 4306 - 4309
  • [38] Accuracy of robotic coil positioning during transcranial magnetic stimulation
    Goetz, Stefan M.
    Kozyrkov, I. Cassie
    Luber, Bruce
    Lisanby, Sarah H.
    Murphy, David L. K.
    Grill, Warren M.
    Peterchev, Angel, V
    JOURNAL OF NEURAL ENGINEERING, 2019, 16 (05)
  • [39] COMPUTATIONAL MODEL OF CEREBELLAR TRANSCRANIAL DIRECT CURRENT STIMULATION
    Parazzini, M.
    Rossi, E.
    Ferrucci, R.
    Fiocchi, S.
    Liorni, I.
    Priori, A.
    Ravazzani, P.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 237 - 240
  • [40] Designing a Transcranial Magnetic Stimulator Coil for Deep Brain Stimulation
    Hasan, Md Mahmudul
    Abu Sufian, Shahed Md.
    Mehdi, Hasan
    Siddique-e-Rabbani, Khondkar
    2016 9TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (ICECE), 2016, : 303 - 306