摘要
Computed tomography (CT) is a medical imaging technology that projects computer-processed X-rays to acquire tomographic images or the slices of specific organ of body. A motion artifact caused by patient motion is a common problem in CT system and may introduce undesirable artifacts in CT images. This paper analyzes the critical problems in motion artifacts and proposes a new CT system for motion artifact compensation. We employ depth cameras to capture the patient motion and account it for the CT image reconstruction. In this way, we achieve the significant improvement in motion artifact compensation, which is not possible by previous techniques.
引用
收藏
页数:8
相关论文
共 10 条
[1]   Lung motion correction on respiratory gated 3-D PET/CT images [J].
Dawood, M ;
Lang, N ;
Jiang, XY ;
Schäfers, KP .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (04) :476-485
[2]   Development of a dynamic model for the lung lobes and airway tree in the NCAT phantom [J].
Garrity, JM ;
Segars, WP ;
Knisley, SB ;
Tsui, BMW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (03) :378-383
[3]  
Hsieh J., 2009, Computed Tomography, P207
[4]   Technical principles of dual source CT [J].
Petersilka, Martin ;
Bruder, Herbert ;
Krauss, Bernhard ;
Stierstorfer, Karl ;
Flohr, Thomas G. .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) :362-368
[5]   MINIMUM SCAN SPEEDS FOR SUPPRESSION OF MOTION ARTIFACTS IN CT [J].
RITCHIE, CJ ;
GODWIN, JD ;
CRAWFORD, CR ;
STANFORD, W ;
ANNO, H ;
KIM, Y .
RADIOLOGY, 1992, 185 (01) :37-42
[6]   PREDICTIVE RESPIRATORY GATING - A NEW METHOD TO REDUCE MOTION ARTIFACTS ON CT SCANS [J].
RITCHIE, CJ ;
HSIEH, J ;
GARD, MF ;
GODWIN, JD ;
KIM, YM ;
CRAWFORD, CR .
RADIOLOGY, 1994, 190 (03) :847-852
[7]   Modelling individual geometric variation based on dominant eigenmodes of organ deformation:: implementation and evaluation [J].
Söhn, M ;
Birkner, M ;
Yan, D ;
Alber, M .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (24) :5893-5908
[8]   Variability of four-dimensional computed tomography patient models [J].
Sonke, Jan-Jakob ;
Lebesque, Joos ;
Van Herk, Marcel .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (02) :590-598
[9]   Motion compensated fan-beam reconstruction for nonrigid transformation [J].
Taguchi, Katsuyuki ;
Kudo, Hiroyuki .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (07) :907-917
[10]   Data consistency based rigid motion artifact reduction in fan-beam CT [J].
Yu, Hengyong ;
Wang, Ge .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2007, 26 (02) :249-260