Sensitivity of Electronic Portal Imaging Device (EPID) Based Transit Dosimetry to Detect Inter-fraction Patient Variations

被引:4
作者
Bawazeer, Omemh [1 ,2 ]
Sarasanandarajah, Sivananthan [1 ,3 ,4 ]
Herath, Sisira [3 ]
Kron, Tomas [3 ,5 ]
Deb, Pradip [1 ]
机构
[1] RMIT Univ, Discipline Med Radiat, Melbourne, Vic, Australia
[2] Umm Al Qura Univ, Discipline Sci, Mecca, Saudi Arabia
[3] Peter MacCallum Canc Ctr, Dept Phys Sci, Melbourne, Vic, Australia
[4] IAEA, Div Human Hlth, Vienna, Austria
[5] Univ Melbourne, Sir Peter MacCallum Dept Oncol, Melbourne, Vic, Australia
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3 | 2019年 / 68卷 / 03期
关键词
Transit EPID dosimetry; Patient variation SSIM index; QUALITY-ASSURANCE; RADIOTHERAPY; INCIDENTS; ERRORS;
D O I
10.1007/978-981-10-9023-3_86
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The sensitivity of EPID-based transit dosimetry to detect patient variations between treatment fractions is examined using gamma analysis and a structural similarity (SSIM) index. EPID images were acquired for 3-dimensional conformal (3DCRT) and dynamic intensity modulated (dIMRT) radiation therapy fields in multiple fractions. Transit images were converted to doses, transit dose in the first fraction considered the reference dose. Variations in patient position or weight were then introduced in the subsequent fractions. Positional variations were examined using a lung and a head and neck phantoms. Anatomical variations were examined using a slab phantom in three scenarios, with solid water simulating tissue, medium-density fiberboard simulating fat, and Styrofoam simulating lung. The dose difference between the first and subsequent fractions was computed using various gamma criteria and the SSIM index. Using a criterion of 3%/3 mm, EPID can detect positional variations >= 4 mm, and tissue and fat variations >= 1 cm, whereas it cannot detect lung variations up to 4 cm. The sensitivity for 3DCRT is higher than for dIMRT. EPID can detect the most variations when using 3%/1 mm. With the SSIM index, EPID can detect a 2 mm positional variation and 1 cm of lung variation. The factor that optimized the sensitivity of EPID was a reduction in the distance to the agreement criteria. Our study introduces the SSIM as an alternative analysis with high sensitivity for minimal variations.
引用
收藏
页码:477 / 480
页数:4
相关论文
共 9 条
[1]   Quantifying the performance of in vivo portal dosimetry in detecting four types of treatment parameter variations [J].
Bojechko, C. ;
Ford, E. C. .
MEDICAL PHYSICS, 2015, 42 (12) :6912-6918
[2]   A quantification of the effectiveness of EPID dosimetry and software-based plan verification systems in detecting incidents in radiotherapy [J].
Bojechko, Casey ;
Phillps, Mark ;
Kalet, Alan ;
Ford, Eric C. .
MEDICAL PHYSICS, 2015, 42 (09) :5363-5369
[3]   Routine EPID in-vivo dosimetry in a reference point for conformal radiotherapy treatments [J].
Fidanzio, Andrea ;
Azario, Luigi ;
Greco, Francesca ;
Cilla, Savino ;
Piermattei, Angelo .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (08) :N141-N150
[4]   Can a commercially available EPID dosimetry system detect small daily patient setup errors for cranial IMRT/SRS? [J].
Hsieh, Emmelyn S. ;
Hansen, Katherine S. ;
Kent, Michael S. ;
Saini, Sanjeev ;
Dieterich, Sonja .
PRACTICAL RADIATION ONCOLOGY, 2017, 7 (04) :E283-E290
[5]   Overview of 3-year experience with large-scale electronic portal imaging device-based 3-dimensional transit dosimetry [J].
Mijnheer, Ben J. ;
Gonzalez, Patrick ;
Olaciregui-Ruiz, Igor ;
Rozendaal, Roel A. ;
van Herk, Marcel ;
Mans, Anton .
PRACTICAL RADIATION ONCOLOGY, 2015, 5 (06) :E679-E687
[6]   A Swiss cheese error detection method for real-time EPID-based quality assurance and error prevention [J].
Passarge, Michelle ;
Fix, Michael K. ;
Manser, Peter ;
Stampanoni, Marco F. M. ;
Siebers, Jeffrey V. .
MEDICAL PHYSICS, 2017, 44 (04) :1212-1223
[7]   Transit dosimetry in dynamic IMRT with an a-Si EPID [J].
Sabet, Mahsheed ;
Rowshanfarzad, Pejman ;
Menk, Fred W. ;
Greer, Peter B. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2014, 52 (07) :579-588
[8]   Image quality assessment: From error visibility to structural similarity [J].
Wang, Z ;
Bovik, AC ;
Sheikh, HR ;
Simoncelli, EP .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2004, 13 (04) :600-612
[9]   Quality assurance in radiotherapy: evaluation of errors and incidents recorded over a 10 year period [J].
Yeung, TK ;
Bortolotto, K ;
Cosby, S ;
Hoar, M ;
Lederer, E .
RADIOTHERAPY AND ONCOLOGY, 2005, 74 (03) :283-291