Clinical and ultrasonographic findings in the mammary gland of sheep

被引:24
作者
Franz, S
Hofmann-Parisot, M
Gütler, S
Baumgartner, W
机构
[1] Univ Vet Med Vienna, Med Univ Clin Ruminants & Swine 2, A-1021 Vienna, Austria
[2] Univ Vet Med Vienna, Inst Med Phys & Biostat, A-1021 Vienna, Austria
关键词
sheep; mammary gland; teat; anatomy; ultrasonography; udder health;
D O I
10.1080/00480169.2003.36373
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
AIM: To compare clinical and ultrasonographic findings and assess the value of ultrasonography for evaluating the structure and condition of the teat and teat canal of sheep. METHODS: The mammary glands of 30 lactating ewes were examined clinically and using ultrasonography. The distance from the teat tip to the ground was measured and diagnostic images of the body of the gland, gland cistern and teat cistern were obtained using an 8.5 MHz frequency ultrasonic transducer. A California mastitis test (CMT) and bacteriological culture were performed on milk samples collected from each half of each udder. RESULTS: Udder parenchyma and teats were palpably normal in 27/30 (90%) ewes. Milk clots or abnormalities were evident in 4/30 (13%) udders, lesions in the glandular parenchyma and/or teats were evident by palpation in 3/30 (10%), and pathogenic bacteria were cultured from 2/30 (7%). In both of the latter cases, mastitis was diagnosed based on clotted and discoloured appearance of milk and highly positive CMT reactions. Ultrasonographic examination in these udders revealed non-homogenous regions in the glandular tissue and alternating areas of hyperechogenic and hypoechogenic tissue. Overall, highly positive CMT reactions were evident in milk from 14/30 (47%) left halves and 9/30 (30%) right halves (p = 0.02). No relationship between teat-to-ground distances and CMT results was evident (p > 0.05). Teat canal lengths ranged from 5.7-10.3 nun (mean = 8.6; SD = 1.3 mm) and the widths from 1.8-3.1 mm (mean = 2.3; SD = 0.4 mm). Milk sampled from ewes that had long (greater than or equal to9 mm) or wide (greater than or equal to2 mm) teat canals was highly positive to the CMT in 75% and 83% of cases, respectively. CONCLUSIONS: Ultrasonographic measurements of the length and width of the teat canal appeared to correlate with CMT results. The use of ultrasonography in evaluating the health of the udder of small ruminants holds promise for the future.
引用
收藏
页码:238 / 243
页数:6
相关论文
共 48 条
[1]  
Banting A., 1998, Cattle Practice, V6, P121
[2]  
Baumgartner W., 1999, KLIN PROPADEUTIK INN, P268
[3]  
Bedo S, 1995, ACTA VET HUNG, V43, P463
[4]  
BIEDERMANN G, 1994, ZUCHTUNGSKUNDE, V66, P38
[5]  
BOSTEDT H, 1996, SCHAF ZIEGENKRANKHEI, P439
[6]   B-MODE ULTRASONOGRAPHY OF MAMMARY-GLANDS OF COWS, GOATS AND SHEEP DURING ALPHA-ADRENERGIC AND BETA-ADRENERGIC AGONIST AND OXYTOCIN ADMINISTRATION [J].
BRUCKMAIER, RM ;
BLUM, JW .
JOURNAL OF DAIRY RESEARCH, 1992, 59 (02) :151-159
[7]  
DEDIE K, 1985, SCHAFKRANKHEITEN, P246
[8]  
DEUTZ A, 1990, WIEN TIERARZTL MONAT, V77, P70
[9]  
DIERNHOFER K, 1950, WIEN TIERARZTL MSCHR, V37, P809
[10]  
EIBL G, 1991, THESIS VETERINARMEDI