Preconcentration of Nicotinamide Using Molecularly Imprinted Microspheres for Solid-phase Extraction with Determination by High-performance Liquid Chromatography

被引:2
|
作者
Wu, Dengyu [1 ]
Li, Li [1 ]
Zhu, Yongyan [1 ]
Li, Zhijian [1 ]
Zhu, Quanhong [1 ]
机构
[1] Southern Med Univ, Sch Tradit Chinese Med, South Shatai Rd 1023, Guangzhou 510515, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Biological samples; high-performance liquid chromatography; molecularly imprinted polymeric microspheres; nicotinamide; solid-phase extraction; ACID; POLYMERS; SAMPLES; PLASMA; URINE; NIACINAMIDE;
D O I
10.1080/00032719.2017.1308373
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of target molecules in complicated matrices such as biological samples is largely dependent on sample pretreatment. Molecularly imprinted solid-phase extraction (SPE), using molecularly imprinted polymers as the adsorbent, has been demonstrated to be effective for the selective enrichment of target molecules in biological samples. In this study, molecularly imprinted polymeric microspheres were fabricated by two-step swelling polymerization using polystyrene particles as seeds, nicotinamide as the template, methacrylic acid as a functional monomer, and ethylene glycol dimethacrylate as a cross-linker. The molecularly imprinted polymeric microspheres were packed into empty SPE cartridges, and the spiked urine and serum samples were loaded separately. After an initial washing and elution step, the effluents were analyzed by high-performance liquid chromatography (HPLC) using 1:9 methanol/0.05% phosphoric acid. The obtained molecularly imprinted polymeric microspheres were uniform, and the spherical particles were well distributed. The established method was validated, and the results showed that the method was linear from 0.499 to 19.96 mu gmL(-1). The limits of detection and quantification for nicotinamide were 0.3 and 0.9 mu gmL(-1), respectively. The relative standard deviations were 1.55 and 2.86% in urine and serum, respectively. The spiked recoveries of nicotinamide were 86.0-98.8% and 87.0-96.8% in urine and serum, respectively. The molecularly imprinted SPE and HPLC methods in this study are useful for the pretreatment and determination of the target compounds in these matrices.
引用
收藏
页码:2560 / 2578
页数:19
相关论文
共 50 条
  • [21] Analysis of sulfamerazine in pond water and several fishes by high-performance liquid chromatography using molecularly imprinted solid-phase extraction
    Linyuan Guo
    Xiaoman Jiang
    Cailing Yang
    Haixia Zhang
    Analytical and Bioanalytical Chemistry, 2008, 391 : 2291 - 2298
  • [22] Analysis of sulfamerazine in pond water and several fishes by high-performance liquid chromatography using molecularly imprinted solid-phase extraction
    Guo, Linyuan
    Jiang, Xiaoman
    Yang, Cailing
    Zhang, Haixia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (06) : 2291 - 2298
  • [23] Molecularly imprinted dispersive micro solid-phase extraction coupled with high-performance liquid chromatography for the determination of four aflatoxins in various foods
    Thati, Ramya
    Seetha, Bala Subrahanyam
    Alegete, Pallavi
    Mudiam, Mohana Krishna Reddy
    FOOD CHEMISTRY, 2024, 433
  • [24] Determination of Sulfonamides in Feeds by High Performance Liquid Chromatography with Molecularly Imprinted Solid Phase Extraction
    Du Bi-Bai
    Xu Yang
    Huang Yun-Hong
    Kang Min
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (12) : 1871 - 1876
  • [25] Preconcentration and determination of high leachable pesticides residues in water using solid-phase extraction coupled with high-performance liquid chromatography
    Al-Degs, Yahya S.
    Al-Ghouti, Mohammad A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2008, 88 (07) : 487 - 498
  • [26] Molecularly imprinted solid-phase extraction for the selective determination of 17β-estradiol in fishery samples with high performance liquid chromatography
    Jiang, Tianhe
    Zhao, Lixia
    Chu, Baolin
    Feng, Qinzhong
    Yan, Wei
    Lin, Jin-Ming
    TALANTA, 2009, 78 (02) : 442 - 447
  • [27] Molecularly imprinted solid-phase extraction for the selective determination of bromhexine in human serum and urine with high performance liquid chromatography
    Javanbakht, Mehran
    Namjumanesh, Mohammad Hadi
    Akbari-Adergani, Behrouz
    TALANTA, 2009, 80 (01) : 133 - 138
  • [28] Determination of sulfadiazine in Jiaozhou Bay using molecularly imprinted solid-phase extraction followed by high-performance liquid chromatography with a diode-array detector
    Lian, Ziru
    He, Xingliang
    Wang, Jiangtao
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 957 : 53 - 59
  • [29] Simultaneous Determination of Three Trace Organophosphorus Pesticide Residues in Vegetables Using Molecularly Imprinted Solid-Phase Extraction Coupled with High-Performance Liquid Chromatography
    Wang, Qingqing
    Zhang, Xin
    Xu, Zhixiang
    Gao, Huiju
    FOOD ANALYTICAL METHODS, 2015, 8 (08) : 2044 - 2051
  • [30] Simultaneous Determination of Three Trace Organophosphorus Pesticide Residues in Vegetables Using Molecularly Imprinted Solid-Phase Extraction Coupled with High-Performance Liquid Chromatography
    Qingqing Wang
    Xin Zhang
    Zhixiang Xu
    Huiju Gao
    Food Analytical Methods, 2015, 8 : 2044 - 2051