Simultaneous assessment of pulsating and total blood in inflammatory skin lesions using functional diffuse reflectance spectroscopy in the visible range

被引:9
作者
Seo, InSeok [1 ]
Bargo, Paulo R. [1 ]
Kollias, Nikiforos [1 ]
机构
[1] Johnson & Johnson Consumer Prod Co, Skillman, NJ 08558 USA
关键词
skin lesion; blood flow; diffuse reflectance spectra; heart pulsation;
D O I
10.1117/1.3524191
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present a simple and cost-effective optical technique for the simultaneous assessment of pulsating and total blood noninvasively in an inflammatory skin lesion. Acquisitions of diffuse reflectance spectra in the visible range at 6 Hz are used to trace the oscillating components of reflectance. Measurements on erythematous lesions from a UV insult show slow changing signal at about 0.1 Hz and heart-driven regular oscillations at about 1 Hz simultaneously. The results demonstrate the potential of the technique in monitoring both pulsating and steady components of the blood in inflammatory lesions of the skin. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3524191]
引用
收藏
页数:3
相关论文
共 10 条
[1]  
JOHNSON BE, 1968, PHOTOPHYSIOLOGY CURR, P139
[2]   Interpreting diffuse reflectance for in vivo skin reactions in terms of chromophores [J].
Kollias, Nikiforos ;
Seo, InSeok ;
Bargo, Paulo R. .
JOURNAL OF BIOPHOTONICS, 2010, 3 (1-2) :15-24
[3]   Non-contact, automated cardiac pulse measurements using video imaging and blind source separation [J].
Poh, Ming-Zher ;
McDuff, Daniel J. ;
Picard, Rosalind W. .
OPTICS EXPRESS, 2010, 18 (10) :10762-10774
[4]   Optical noninvasive monitoring of skin blood pulsations [J].
Spigulis, J .
APPLIED OPTICS, 2005, 44 (10) :1850-1857
[5]   Simultaneous recording of skin blood pulsations at different vascular depths by multiwavelength photoplethysmography [J].
Spigulis, Janis ;
Gailite, Lasma ;
Lihachev, Alexey ;
Erts, Renars .
APPLIED OPTICS, 2007, 46 (10) :1754-1759
[6]   In vivo measurement of skin erythema and pigmentation:: new means of implementation of diffuse reflectance spectroscopy with a commercial instrument [J].
Stamatas, G. N. ;
Zmudzka, B. Z. ;
Kollias, N. ;
Beer, J. Z. .
BRITISH JOURNAL OF DERMATOLOGY, 2008, 159 (03) :683-690
[7]   Blood stasis contributions to the perception of skin pigmentation [J].
Stamatas, GN ;
Kollias, N .
JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (02) :315-322
[8]   POTENTIAL ERRORS IN PULSE OXIMETRY .2. EFFECTS OF CHANGES IN SATURATION AND SIGNAL QUALITY [J].
WEBB, RK ;
RALSTON, AC ;
RUNCIMAN, WB .
ANAESTHESIA, 1991, 46 (03) :207-212
[9]   LASER DOPPLER VELOCIMETRY TO QUANTIFY UV-B INDUCED INCREASE IN HUMAN-SKIN BLOOD-FLOW [J].
YOUNG, AR ;
GUY, RH ;
MAIBACH, HI .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1985, 42 (04) :385-390
[10]   Skin melanin, hemoglobin, and light scattering properties can be quantitatively assessed in vivo using diffuse reflectance spectroscopy [J].
Zonios, G ;
Bykowski, J ;
Kollias, N .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2001, 117 (06) :1452-1457