Fault Evolution Testability Modeling and Analysis for Centrifugal Pumps

被引:0
作者
Tan Xiaodong [1 ]
Qiu Jing [1 ]
Liu Guanjun [1 ]
Li Qing [2 ]
机构
[1] Natl Univ Def Technol, Sci & Technol Integrated Logist Support Lab, Changsha, Hunan, Peoples R China
[2] Officers Coll CAPF, Dept Elect Technol, Chengdu, Sichuan, Peoples R China
来源
PROCEEDINGS OF 2014 PROGNOSTICS AND SYSTEM HEALTH MANAGEMENT CONFERENCE (PHM-2014 HUNAN) | 2014年
关键词
Centrifugal pump; Design for Testability(DFT); Health and Performance Monitoring (HPM); Fault Evolution Testability Model(FETM);
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Centrifugal pump is one of the most used pump types in industrial applications, and Health and Performance Monitoring (HPM) of pumps using lots of tests can prevent loss caused by failures. Therefore, Design for Testability (DFT) need be implemented in order to reduce the test costs as much as possible on the basis of meeting the HPM requirements. As the basis of DFT, testability model can improve its efficiency. Hence, a Fault Evolution Testability Model (FETM) for centrifugal pumps is proposed and testability analysis method considering HPM requirements is developed in this paper. Finally, the results of case study show that FETM can correctly describe the relationships between fault growth and tests, and testability analysis proposed in this paper can help DFT to improve HPM level.
引用
收藏
页码:469 / 473
页数:5
相关论文
共 50 条
[31]   Complex optimal design of centrifugal pumps [J].
Yalovoi, NS ;
Kats, AM .
CHEMICAL AND PETROLEUM ENGINEERING, 1999, 35 (11-12) :762-764
[32]   Sealing centrifugal pumps in the chemical industry [J].
Martsinkovskii, VS ;
Ovseiko, IV ;
Skirdachenko, EI .
CHEMICAL AND PETROLEUM ENGINEERING, 2003, 39 (11-12) :666-668
[33]   Complex optimal design of centrifugal pumps [J].
N. S. Yalovoi ;
A. M. Kats .
Chemical and Petroleum Engineering, 1999, 35 :762-764
[34]   Sealing Centrifugal Pumps in the Chemical Industry [J].
V. S. Martsinkovskii ;
I. V. Ovseiko ;
E. I. Skirdachenko .
Chemical and Petroleum Engineering, 2003, 39 :666-668
[35]   A Modular Soft Sensor for Centrifugal Pumps [J].
Leonow, Sebastian ;
Zhang, Qi ;
Monnigmann, Martin .
IFAC PAPERSONLINE, 2024, 58 (14) :91-96
[36]   Cavitation Severity Detection in Centrifugal Pumps [J].
Azizi, Razieh ;
Hajnayeb, Ali ;
Ghanbarzadeh, Afshin ;
Changizian, Maziar .
ADVANCES IN TECHNICAL DIAGNOSTICS, 2018, 10 :47-55
[37]   A Deep Learning Approach for Fault Diagnosis in Centrifugal Pumps through Wavelet Coherent Analysis and S-Transform Scalograms with CNN-KAN [J].
Siddique, Muhammad Farooq ;
Ullah, Saif ;
Kim, Jong-Myon .
CMC-COMPUTERS MATERIALS & CONTINUA, 2025, 84 (02) :3577-3603
[38]   Fast Detection of Centrifugal Pumps Condition by Structural Analysis of MEMS Sensor Signals [J].
de Araujo, Rodrigo D. B. ;
Rocha, Joao M. M. ;
dos Santos, Matheus A. ;
Ramalho, Geraldo L. B. .
JOURNAL OF CONTROL AUTOMATION AND ELECTRICAL SYSTEMS, 2022, 33 (01) :293-303
[39]   Analysis of particle motion and wear characteristics for mixed particle sizes in centrifugal pumps [J].
Yi Li ;
Haiyang Zhang ;
Zhe Lin ;
Guang Zhang ;
Zuchao Zhu .
Journal of Mechanical Science and Technology, 2023, 37 :4705-4716
[40]   Analysis of particle motion and wear characteristics for mixed particle sizes in centrifugal pumps [J].
Li, Yi ;
Zhang, Haiyang ;
Lin, Zhe ;
Zhang, Guang ;
Zhu, Zuchao .
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2023, 37 (09) :4705-4716