Two metformin carbon paste and PVC electrodes are proposed for the determination of metformin. Different methods for electrode fabrication (including formation of the ion pair in situ, soaking of the electrode in the ion pair aqueous solution, in addition to the classical modification of the electrode matrix with the ion pair) are described for both carbon paste and PVC electrodes. Electrodes based on in situ ion pairs of metformin with sodium tetrakis (4-fluorophenyl) berate or tungstophosphoric acid respectively showed the best performance compared with the other methods of preparation. These electrodes exhibit a linear response with a good Nernstian slope over a concentration range 10(-5)-10(-1) M of metformin in a working pH range between 4 and 8. The effect of the electrode matrix composition and plasticizer on the performance of both carbon paste and PVC electrodes are investigated for each fabrication method. The proposed technique was applied successfully for the determination of metformin in pure solutions and in dosage forms with good accuracy and precision. The results were compared statistically with those given by the reported method.
引用
收藏
页码:262 / 267
页数:6
相关论文
共 47 条
[1]   New triiodomercurate-modified carbon paste electrode for the potentiometric determination of mercury [J].
Abbas, MN ;
Mostafa, GAE .
ANALYTICA CHIMICA ACTA, 2003, 478 (02) :329-335
[2]  
Antropov L. I., 1972, THEORETICAL ELECTROC
[3]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[4]   Determination of pharmaceutical compounds in surface- and ground-water samples by solid-phase extraction and high-performance liquid chromatography-electrospray ionization mass spectrometry [J].
Cahill, JD ;
Furlong, ET ;
Burkhardt, MR ;
Kolpin, D ;
Anderson, LG .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1041 (1-2) :171-180
[5]  
CAI L, 1987, ANAL P, V24, P339
[6]   ION-SELECTIVE ELECTRODES IN ORGANIC-ANALYSIS - DETERMINATION OF XANTHATE [J].
CHAN, WH ;
LEE, AWM ;
FUNG, KT .
TALANTA, 1988, 35 (10) :807-809
[7]  
Cosofret V.V., 1992, PHARM APPL MEMBRANE
[8]   Retention behavior of metformin and related impurities in ion-pairing liquid chromatography [J].
David, V ;
Medvedovici, A ;
Albu, F .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (01) :81-95
[9]   SPECTROPHOTOMETRIC DETERMINATION OF METFORMIN VIA CHARGE-TRANSFER COMPLEX WITH IODINE [J].
ELBARDICY, MG ;
ELKHATEEB, SZ ;
AHMAD, AKS ;
ASSAAD, HN .
SPECTROSCOPY LETTERS, 1989, 22 (09) :1173-1181
[10]  
George W., 2004, HDB PLASTICIZERS