Malposition of selective cerebral perfusion catheter is not a rare event

被引:39
作者
Orihashi, K [1 ]
Sueda, T [1 ]
Okada, K [1 ]
Imai, K [1 ]
机构
[1] Hiroshima Univ Hosp, Div Cardiovasc Surg, Minami Ku, Hiroshima 7348551, Japan
关键词
selective cerebral malperfusion; aortic arch aneurysm; transesophageal echocardiography; malperfusion; near-infrared spectroscopy;
D O I
10.1016/j.ejcts.2004.12.046
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Although malposition of a catheter for selective cerebral perfusion can lead to postoperative neurologic complications, the clinical relevance or even an incidence of this event is not clear because there have been no measures to diagnose it. The purpose of this study is to report the results of intraoperative diagnosis of catheter malposition by means of near-infrared spectroscopy, orbital ultrasound, and transesophageal echocardiography. Methods: The 35 consecutive patients of aortic arch aneurysm undergoing total arch replacement (13 patients) or transaortic stent graft implantation (22 patients) were examined. The regional oxygen saturation in the frontal lobe was continuously monitored with near-infrared spectroscopy. When cerebral malperfusion was suspected with saturation drop and reduced blood flow in orbital ultrasound, blood flow in the cervical branches and catheter position were examined with transesophageal echocardiography. Results: Catheter malposition was detected in 4 of 35 cases (11.4%). The echo findings included: (1) reduced or absent flow and/or collapsed lumen in the common carotid artery despite an adequate perfusion rate; and (2) the balloon of catheter blocking the inflow to the common carotid artery. There was no unusual changes in parameters of other conventional monitors. After the catheter was withdrawn (three cases) or replaced (one case) based on the above diagnosis, cerebral perfusion was restored, confirmed by these three modalities. An accidental entry of catheter into the right common carotid artery was detected by transesophageal echocardiography in one case, in which there was no abnormal finding of oxygen saturation or orbital blood flow. Conclusions: Catheter malposition on the right side is not a rare event during selective cerebral perfusion. The catheter can migrate into the right subclavian artery or common carotid artery. Pressure monitoring cannot reliably detect an occurrence of catheter migration into the right subclavian artery. Combined use of near-infrared spectroscopy, orbital ultrasound, and transesophageal echocardiography can be useful for detecting this event and making an appropriate decision without delay to prevent irreversible brain damage. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:644 / 648
页数:5
相关论文
共 50 条
[21]   Arterio-jugular differences in serum S-100β proteins in patients receiving selective cerebral perfusion [J].
Kunihara, T ;
Shiiya, N ;
Bin, L ;
Yasuda, K .
SURGERY TODAY, 2006, 36 (01) :6-11
[22]   Arterio-jugular Differences in Serum S-100β Proteins in Patients Receiving Selective Cerebral Perfusion [J].
Takashi Kunihara ;
Norihiko Shiiya ;
Luo Bin ;
Keishu Yasuda .
Surgery Today, 2006, 36 :6-11
[23]   Transesophageal echocardiography reveals left atrial malposition of a Fogarty catheter during inferior vena cava thrombectomy [J].
Meier, Stefan ;
Hartmann, Matthias .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2006, 20 (03) :405-406
[24]   Monitoring of antegrade selective cerebral perfusion for aortic arch surgery with transcranial Doppler ultrasonography and near-infrared spectroscopy [J].
Yu, QJ ;
Sun, LZ ;
Chang, Q ;
Sun, GM ;
Liu, J .
CHINESE MEDICAL JOURNAL, 2001, 114 (03) :257-261
[25]   Cerebrovascular Impedance as a Function of Cerebral Perfusion Pressure [J].
Yang, Jason ;
Acharya, Deepshikha ;
Scammon, William B. ;
Schmitt, Samantha ;
Crane, Emily C. ;
Smith, Matthew A. ;
Kainerstorfer, Jana M. .
IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY, 2023, 4 :96-101
[26]   Optimal cerebral perfusion pressure: are we ready for it? [J].
Lazaridis, Christos ;
Smielewski, Piotr ;
Steiner, Luzius A. ;
Brady, Ken M. ;
Hutchinson, Peter ;
Pickard, John D. ;
Czosnyka, Marek .
NEUROLOGICAL RESEARCH, 2013, 35 (02) :138-148
[27]   Optimal flow rate for antegrade cerebral perfusion [J].
Sasaki, Takashi ;
Tsuda, Shoichi ;
Riemer, R. Kirk ;
Ramamoorthy, Chandra ;
Reddy, V. Mohan ;
Hanley, Frank L. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (03) :530-535
[28]   Optical Technique for Estimating Cerebral Perfusion Pressure [J].
Chen, Chang-Ting ;
Liao, Yi-Chien ;
Lai, Chien-Fu ;
Lin, Bor-Shyh ;
Wang, Che-Chuan ;
Kuo, Jinn-Rung .
2015 INTERNATIONAL CONFERENCE ON INTELLIGENT INFORMATION HIDING AND MULTIMEDIA SIGNAL PROCESSING (IIH-MSP), 2015, :57-59
[29]   Surgical management of atherosclerotic aortic arch aneurysms using selective cerebral perfusion: 7-year experience in 52 patients [J].
Shiiya, N ;
Kunihara, T ;
Imamura, M ;
Murashita, T ;
Matsui, Y ;
Yasuda, K .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (03) :266-271
[30]   Postoperative brain complications following retrograde cerebral perfusion [J].
Sato, Y ;
Ishikawa, S ;
Otaki, A ;
Takahasai, T ;
Hasegawa, Y ;
Koyano, T ;
Yamagishi, T ;
Oki, S ;
Morishita, Y .
SURGERY TODAY-THE JAPANESE JOURNAL OF SURGERY, 1999, 29 (10) :1034-1039