On the nature and propagation of errors in roughness parameters obtained from spectral analysis of atomic force microscopy topographic images

被引:3
作者
Chrostowski, Robert [1 ,2 ]
Mangolini, Filippo [1 ,3 ]
机构
[1] Univ Texas Austin, Texas Mat Inst, Austin, TX 78712 USA
[2] Univ Texas Austin, Mat Sci & Engn Program, Austin, TX 78712 USA
[3] Univ Texas Austin, Walker Dept Mech Engn, Austin, TX 78712 USA
来源
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A | 2022年 / 40卷 / 05期
基金
美国国家科学基金会;
关键词
SURFACE-ROUGHNESS; CONTACT MECHANICS; CRYSTALLITE SIZE; RUBBER-FRICTION; MODELS; ADHESION; TRANSFORMATION; SIMULATION; REGRESSION; ALGORITHM;
D O I
10.1116/6.0001998
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Scale-dependent surface roughness strongly affects critical surface properties of materials, including adhesion, wettability, and optical/ thermal properties. As a particular example, tuning the ratio of the true to nominal area-a parameter that depends on the root mean square (RMS) local slope of the finest scales of topography-is an effective approach to tailor the wetting characteristics of solid surfaces. While power spectral density (PSD) analysis of atomic force microscopy (AFM) topographic images allows for directly assessing the scale-dependence of surface roughness, this approach to analyze AFM height maps requires power-law modeling and extrapolation of a PSD with inherently non-normal error distributions. Here, we use a Monte Carlo approach based on synthetic AFM images of known input powerlaw parameters to (1) evaluate the accuracy of fitting techniques based on the expected distribution of the PSD; (2) evaluate the error propagation from the standard errors of the fitted power-law parameters to the computed RMS slope and area ratio; and (3) evaluate the statistical power of various PSD regression techniques when differentiating surfaces. The results indicated that standard error for ordinary least squares on a log-log PSD (log OLS) underpredicts the observed variance by similar to 50%. This underprediction can be eliminated by implementing a log-link gamma regression. Moreover, when propagating the standard error to derived parameters (e.g., the RMS slope), the propagated error is generally conservative relative to the observed variance and closely predicts the observed variance when extrapolating to the finest scale. This result demonstrates the possibility of accurately estimating roughness parameters that are critical for evaluating surface phenomena on the basis of fitting and extrapolating AFM data using self-affine models. Finally, our results provided evidence for the possibility of statistically differentiating surfaces with similar power-law parameters when using weighted gamma regression with a mean of 10 images, as opposed to unweighted log-OLS that requires as many as 10 000 images to differentiate images. Published under an exclusive license by the AVS.
引用
收藏
页数:14
相关论文
共 28 条
  • [21] Surface Roughness Characterization of ZnO:TiO2-Organic Blended Solar Cells Layers by Atomic Force Microscopy and Fractal Analysis
    Talu, Stefan
    Stach, Sebastian
    Ikram, Muhammad
    Pathak, Dinesh
    Wagner, Tomas
    Nunzi, Jean-Michel
    INTERNATIONAL JOURNAL OF NANOSCIENCE, 2014, 13 (03)
  • [22] Atomic force microscopy comparative analysis of the surface roughness of two posterior chamber phakic intraocular lens models: ICL versus IPCL
    Gros-Otero, Juan
    Ketabi, Samira
    Canones-Zafra, Rafael
    Garcia-Gonzalez, Montserrat
    Villa-Collar, Cesar
    Casado, Santiago
    Teus, Miguel A.
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [23] Atomic force microscopy comparative analysis of the surface roughness of two posterior chamber phakic intraocular lens models: ICL versus IPCL
    Juan Gros-Otero
    Samira Ketabi
    Rafael Cañones-Zafra
    Montserrat Garcia-Gonzalez
    Cesar Villa-Collar
    Santiago Casado
    Miguel A. Teus
    BMC Ophthalmology, 21
  • [24] Fractal analysis and atomic force microscopy measurements of surface roughness for Hastelloy C276 substrates and amorphous alumina buffer layers in coated conductors
    Feng, F.
    Shi, K.
    Xiao, S. -Z.
    Zhang, Y. -Y.
    Zhao, Z. -J.
    Wang, Z.
    Wei, J. -J.
    Han, Z.
    APPLIED SURFACE SCIENCE, 2012, 258 (08) : 3502 - 3508
  • [25] Application of atomic force microscopy and scaling analysis of images to predict the effect of current density, temperature and leveling agent on the morphology of electrolytically produced copper
    Zhao, T
    Zagidulin, D
    Szymanski, G
    Lipkowski, J
    ELECTROCHIMICA ACTA, 2006, 51 (11) : 2255 - 2260
  • [26] The effect of cutting parameters on defect detection based on recurrence analysis of cutting force signals obtained from GFRP composite milling
    Kecik, Krzysztof
    Ciecielag, Krzysztof
    MEASUREMENT, 2025, 239
  • [27] Toward an Improved Method for Determining the Hamaker Constant of Solid Materials Using Atomic Force Microscopy. I. Quasi-Static Analysis for Arbitrary Surface Roughness
    Stevenson, Michael C.
    Beaudoin, Stephen P.
    Corti, David S.
    JOURNAL OF PHYSICAL CHEMISTRY C, 2020, 124 (05) : 3014 - 3027
  • [28] Surface roughness and morphology analysis using an atomic force microscopy of polycrystalline diamond coated Si3N4 deposited by microwave plasma assisted chemical vapor deposition
    Purniawan, A.
    Hamzah, E.
    Toff, M. R. M.
    ADVANCED STRUCTURAL AND FUNCTIONAL MATERIALS FOR PROTECTION, 2008, 136 : 153 - 159