Comparison of Anterior and Posterior Corneal Surface Irregularity in Descemet Stripping Automated Endothelial Keratoplasty and Penetrating Keratoplasty

被引:35
作者
Yamaguchi, Takefumi [1 ,2 ]
Negishi, Kazuno
Yamaguchi, Kazuko
Dogru, Murat [3 ]
Uchino, Yuichi
Shimmura, Shigeto
Tsubota, Kazuo
机构
[1] Keio Univ, Sch Med, Dept Ophthalmol, Shinjuku Ku, Tokyo 1608513, Japan
[2] Tokyo Dent Coll, Dept Ophthalmol, Chiba, Japan
[3] Keio Univ, Sch Med, J&J Ocular Surface & Visual Opt Dept, Tokyo 1608513, Japan
关键词
DSAEK; penetrating keratoplasty; astigmatism; irregular astigmatism; anterior corneal surface; posterior corneal surface; LASER ZIGZAG INCISION; FEMTOSECOND-LASER; LAMELLAR KERATOPLASTY; OCULUS PENTACAM; VISION; PACHYMETRY; OUTCOMES; SURGERY; TISSUE; FRONT;
D O I
10.1097/ICO.0b013e3181d0092c
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the irregularity of the anterior and posterior cornea after Descemet stripping automated endothelial keratoplasty (DSAEK) and penetrating keratoplasty (PK). Methods: This clinical study comprised 39 eyes: 13 consecutive eyes after DSAEK, 13 consecutive eyes after PK, and 13 age-matched normal eyes. Corneal elevation data were acquired using a rotating Scheimpflug camera 1 and 3 months after DSAEK and PK. Anterior and posterior corneal elevation data were decomposed into a set of Zernike polynomials up to eighth order. Total higher-order root mean square (RMS) and RMS from third to eighth order were calculated. The astigmatism and irregularity of the anterior and posterior surfaces were compared between DSAEK and PK. Results: The regular astigmatism and tilt components of the anterior surface were significantly lower after DSAEK than after PK at 1 and 3 months (P < 0.001), whereas there was no difference in astigmatism of the posterior surface between the groups (P = 0.07, 0.22). The higher-order RMS and RMSs of third-to eighth-order components of the anterior surface were significantly larger after PK than those after DSAEK at 1 and 3 months (P < 0.01), whereas there were no significant differences between DSAEK and PK in higher-order aberration RMS and RMSs of third-to eighth-order components of the posterior surface. Conclusions: Postoperative corneal irregularity of the anterior surface was greater after PK than after DSAEK, whereas there was no significant difference in posterior surface irregularity. DSAEK is superior to PK in terms of the higher-order irregularity of the anterior surface.
引用
收藏
页码:1086 / 1090
页数:5
相关论文
共 31 条
[1]   Comparison between central corneal thickness measurements by oculus pentacam and ultrasonic pachymetry [J].
Al-Mezaine H.S. ;
Al-Amro S.A. ;
Kangave D. ;
Sadaawy A. ;
Wehaib T.A. ;
Al-Obeidan S. .
International Ophthalmology, 2008, 28 (5) :333-338
[2]   Comparison of posterior lamellar keratoplasty techniques to penetrating keratoplasty [J].
Bahar, Irit ;
Kaiserman, Igor ;
McAllum, Penny ;
Slomovic, Allan ;
Rootman, David .
OPHTHALMOLOGY, 2008, 115 (09) :1525-1533
[3]   Retrospective Contralateral Study Comparing Descemet Stripping Automated Endothelial Keratoplasty With Penetrating Keratoplasty [J].
Bahar, Irit ;
Kaiserman, Igor ;
Levinger, Eliya ;
Sansanayudh, Wiwan ;
Slomovic, Allan R. ;
Rootman, David S. .
CORNEA, 2009, 28 (05) :485-488
[4]   The use of the femtosecond laser in penetrating keratoplasty [J].
Buratto, Lucio ;
Bohm, Elisabetta .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (05) :737-742
[5]   Femtosecond-laser-assisted Descemet's stripping endothelial keratoplasty [J].
Cheng, Yanny Y. Y. ;
Pels, Elisabeth ;
Nuijts, Rudy M. M. A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (01) :152-155
[6]   The shape of the anterior and posterior surface of the aging human cornea [J].
Dubbelman, M ;
Sicarn, VADP ;
Van der Heijde, GL .
VISION RESEARCH, 2006, 46 (6-7) :993-1001
[7]  
Dubbelman M., 2007, J Vis, V7, P1, DOI DOI 10.1167/707010
[8]   Results of penetrating keratoplasty performed with a femtosecond laser zigzag incision initial report [J].
Farid, Marjan ;
Kim, Matthew ;
Steinert, Roger F. .
OPHTHALMOLOGY, 2007, 114 (12) :2208-2212
[9]   Deep anterior lamellar keratoplasty performed with the femtosecond laser zigzag incision for the treatment of stromal corneal pathology and ectatic disease [J].
Farid, Marjan ;
Steinert, Roger F. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (05) :809-813
[10]   Evaluation of deep lamellar endothelial keratoplasty surgery using scatterometry and wavefront analyses [J].
Hindman, Holly B. ;
McCally, Russell L. ;
Myrowitz, Elliot ;
Terry, Mark A. ;
Stark, Walter J. ;
Weinberg, Robert S. ;
Jun, Albert S. .
OPHTHALMOLOGY, 2007, 114 (11) :2006-2012