ICP-MS direct determination of trace amounts of rare earth impurities in various rare earth oxides with only one standard series

被引:12
作者
He, M [1 ]
Hu, B [1 ]
Zeng, Y [1 ]
Jiang, ZC [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
inductively coupled plasma mass spectrometry (ICP-MS); high-purity rare earth oxides; rare earth impurities;
D O I
10.1016/j.jallcom.2004.06.107
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
An inductively coupled plasma mass spectrometry (ICP-MS) method with just one standard series for direct determination of trace rare earth impurities in various rare earth oxides was developed. The spectral interference in ICP-MS analysis of high-purity neodymium (Nd2O3) was thoroughly estimated. For the investigation of matrix effect, high-purity Y2O3 was used as model sample and the experimental results showed that the maximal matrix tolerant amount obtained by stepwise dilution method is comparable to that obtained by conventional method with the use of higher purity Y2O3 as matrix. Under the selected conditions, no obvious matrix effect can be found with the matrix (Y) concentration of less than 500 mug mL(-1). For real sample analysis, 100 mug mL(-1) of matrix was chosen as the sample concentration. The proposed method was applied to the analysis of trace rare earth impurities in different high-purity rare earth oxides (Y2O3, Pr6O11 1 Nd2O3 Dy2O3, ErO3), and the analytical results obtained were in good agreement with the recommended values. The detection limits of the method for rare earth elements were 1-21 ng L-1 with the R.S.D varying between 2.9 and 7.8%, and the percentage recovery ranged from 93 to 115% for the spiked samples. This method was characterized with simplicity, rapidity. sensitivity, small sample amount required, and no internal standard/matrix matching requirements. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:168 / 174
页数:7
相关论文
共 28 条
[1]   Direct determination of trace rare earth elements in high purity Y2O3 using fluorination assisted electrothermal vaporization inductively coupled plasma atomic emission spectrometry with slurry sampling [J].
Cai, B ;
Hu, B ;
Jiang, ZC .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (03) :259-263
[2]   Elimination of the spectral interference from polyatomic ions with rare earth elements in inductively coupled plasma mass spectrometry by combining algebraic correction with chromatographic separation [J].
Cao, XD ;
Yin, M ;
Wang, XR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (04) :431-441
[3]   INTERFERENCES OF OXIDE, HYDROXIDE AND CHLORIDE ANALYTE SPECIES IN THE DETERMINATION OF RARE-EARTH ELEMENTS IN GEOLOGICAL SAMPLES BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
DULSKI, P .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (4-5) :194-203
[4]   INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY - A REVIEW [J].
EVANS, EH ;
GIGLIO, JJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (01) :1-18
[5]   INDUCTIVELY COUPLED ARGON PLASMA AS AN ION-SOURCE FOR MASS-SPECTROMETRIC DETERMINATION OF TRACE-ELEMENTS [J].
HOUK, RS ;
FASSEL, VA ;
FLESCH, GD ;
SVEC, HJ ;
GRAY, AL ;
TAYLOR, CE .
ANALYTICAL CHEMISTRY, 1980, 52 (14) :2283-2289
[6]   Determination of rare earth elements in human blood serum by inductively coupled plasma mass spectrometry after chelating resin preconcentration [J].
Inagaki, K ;
Haraguchi, H .
ANALYST, 2000, 125 (01) :191-196
[7]   Study and application of a method for the determination of metallic elements by ICP-AES with preconcentration on an active carbon-silica gel microcolumn in a FI system [J].
Ji, HN ;
Liao, ZH ;
Sun, JM ;
Jiang, ZC .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (06) :721-723
[8]  
Jiang Z., 2000, ANAL CHEM RARE EARTH
[9]  
Li B., 1994, CARSOL SIN, V13, P17
[10]   DETERMINATION OF THE RARE-EARTH ELEMENTS IN GEOLOGICAL-MATERIALS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
LICHTE, FE ;
MEIER, AL ;
CROCK, JG .
ANALYTICAL CHEMISTRY, 1987, 59 (08) :1150-1157